Appendix E 400W SERIES RS-232 FUEL/AIR DATA INPUT FORMAT

E.1 Electrical Interface
The input signals are compatible with RS-232C. Data input is at 9600 baud with a word length of 8 bits,
one stop bit, and no parity. One message is received per second.
E.2 Shadin Altitude Sentence
The Garmin 400W Series units are capable of receiving the following 17-byte message from Shadin
Altitude Encoders, Altitude Serializers, and Altitude Converters:
Where:
RMS
ASCII characters
<sp>
space (0x20)
<+/-> sign indicator (0x2b["+"] or 0x2d["-"])
12345 altitude in feet
T
ASCII character
<+/-> sign indicator
12
sensor temperature
ul
checksum of bytes 1 through 14 in hex ASCII (i.e., "FA")
<CR> carriage return (0x0d)
Note: Checksum is calculated by adding each byte in the message (1 through 14).
E.3 Icarus Altitude Sentence
The Garmin 400W Series units are capable of receiving the following 10-byte message from the Icarus
Altitude Serializer:
Where:
ALT
ASCII characters
<sp>
space (0x20)
12345 altitude in feet
<CR> carriage return (0x0d)
400W Series Installation Manual
190-00356-02
RMS<sp><+/->12345T<+/->12ul<CR>
ALT<sp>12345<CR>