step 4 - WIrIng tHe Fan

WarNiNg
• To avoid possible electrical
shock, before wiring fan,
disconnect power by turn-
ing off the circuit break-
ers both to the outlet box
and to its associated wall
switch location. If you can-
not lock the circuit break-
ers in the off position, se-
curely fasten a prominent
warning device, such as a
tag, to the service panel.
• All wiring must be in accor-
dance with national and lo-
cal electrical codes. If you
are unfamiliar with wiring,
you should use a qualified
44204-01
5/30/2007
WarNiNg
To reduce the risk of fire, elec-
trical shock, or motor damage,
do not lift or carry the fan by
Disconnect the power by turning
off the circuit breakers to the outlet
box and associated wall switch
location.
CoNNeCtiNg FaN to eleC-
triCal sourCe
Use Figure 4 for reference in mak-
ing the following electrical connec-
tions.
1. Connect the supply mains with a
wire nut.
2. Connect the earth wire and the
green/yellow ground wire from
the hanger.
3. Connect the blue neutral wire to
the blue wire from the fan.
4. Connect the brown line wire to
the brown wire from the fan.
Note: Unless there is a sepa-
rate line for the light kit, connect
the black/white wire and brown
wire from the motor housing to
the brown wire from the ceil-
ing.
CautioN
Be sure no bare wire or wire
strands are visible after mak-
ing connections.