Component Testing Procedures
To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless
testing requires power.
"Quick Test" Mode for Non-Self Clean Control
Follow procedure below to use the quick test mode. Entries must be made within 32 seconds of each other or the
control will exit the quick test mode.
1. Press and hold Cancel and Broil keypads for 3 to 5 seconds within 5 minutes of applying power.
2. Once the control has entered the "Quick Test" mode, release both keypads.
3. Press each of the following keypads indicated in the table below.
NOTE:
Press the keypad once to activate the response.
Press the keypad a second time to deactivate the response.
Display will indicate the following:
Keypad
[Bake]
[Broil]
[Timer]
[Clock]
[Up Arrow]
[Down Arrow]
[Cancel]
Description of Error Codes
Error diagnostic codes can only be viewed by entering the Diagnostic Code Display Mode.
Each error code consists of four digits and each digit is described in the following table.
Digit
st
1
nd
2
rd
3
th
4
14
!
Operation
Bake relay activated
Broil relay activated
DLB relay activated
Alternate between ODD
LED SEGMENTS and
EVEN LED
SEGMENTS on each
key press
EEPROM version
number
Code version number
Exit Factory Test Mode
Primary System:
1 – Local to the control circuit board
3 – Sensor and/or meat probe
4 – Control input
Measurable:
d – Diagnostic: measurable parameter
c – Control related, replace control
Secondary System: Sequential numbering
Oven Cavity:
1 – Oven
c – Control specific
WARNING
Description
16026839
© 2006 Maytag Services