Pos.
Title
6
In conjunction with the Vitotronic 200-H:
Immersion temperature sensor (Viessmann NTC) as cylinder temperature sensor
7
Feed pump (distributor)
Sample application 3 – Vitocell 100-L with Vitotrans 222 and constant flow temperatures
A Power supply connection 230 V~ 50 Hz; install a mains isolator in
accordance with regulations
B Heating circuit pump (primary), highly efficient
Cylinder heating will be initiated by the upper temperature controller.
The lower temperature controller terminates cylinder heating.
You can select the temperature at the temperature controller.
Example:
Max. 55 ºC ON, 50 ºC OFF (at heating temperature 60 ºC).
Required components
Pos.
Title
1
Vitocell 100-L, 500 l (shown), or
Vitocell 100-L, 750 l, or
Vitocell 100-L, 1000 l
2
Vitotrans 222
– up to 80 kW
– up to 120 kW
7
– up to 240 kW
3
Junction box
4
*17
Contactor relay
5
Temperature controller
6
*17
Motorised valve
Only required for pressurised flow distributors.
*17
VIESMANN
48
(cont.)
M
C Cylinder loading pump (secondary), highly efficient
D Flow distributor (under pressure)
E Return collector
Install a motorised valve in the flow line when connecting the Vitotrans
222 heat exchanger set for constant flow temperatures without mixer
assembly to a flow distributor (under pressure) (boiler with heating cir-
cuit pump to distributor). The motorised valve will be closed during non-
heating periods, preventing a forced flow through the Vitotrans 222
during such times.
Number
Part no.
1
7438 702
subject to system
on site
Number
Part no.
subject to system
Z002 074
subject to system
Z004 042
subject to system
Z004 043
1
7453 039
1
7453 040
1
7453 041
1
on site
1
7814 681
2
7151 989
1
on site
DHW heating