Selecting the cylinder type

Table for selection according to continuous output

Flow temperature
Vitocell 100-H, 130 l, type CHA
Vitocell 100-H, 160 l, type CHA
Vitocell 100-H, 200 l, type CHA
Horizontal DHW
Vitocell 300-H, 160 l, type EHA
cylinders
Vitocell 300-H, 200 l, type EHA
Vitocell 300-H, 350 l, type EHA
Vitocell 300-H, 500 l, type EHA
3
Vitocell 100-W, 120 l, type CUG
DHW cylinders
for wall mounted
Vitocell 100-W, 150 l, type CUG
boilers
Vitocell 100-V, 160 l, type CVA
Vitocell 100-V, 200 l, type CVA
3
Vitocell 100-V, 300 l, type CVA
Vitocell 100-V, 500 l, type CVA
Vitocell 100-V, 750 l, type CVA
Vitocell 100-V, 1000 l, type CVA
Vertical DHW cyl-
Vitocell 100-V, 390 l, type CVW
inders
Vitocell 300-V 130 l, type EVA
Vitocell 300-V 160 l, type EVA
Vitocell 300-V 200 l, type EVA
Vitocell 300-V, 200 l, type EVI
Vitocell 300-V, 300 l, type EVI
Vitocell 300-V, 500 l, type EVI
Vitocell 100-U, 300 l, type CVUA
Vitocell 100-B, 300 l, type CVB
Vitocell 100-B, 400 l, type CVB
Dual mode DHW
cylinders A
Vitocell 100-B, 500 l, type CVB
Vitocell 300-B, 300 l, type EVB
Vitocell 300-B, 500 l, type EVB
Freshwater mod-
Vitotrans 353, type PBS, type PZS
ule
Vitotrans 353, type PBM, type PZM
Vitotrans 353, type PBL
1 - 3 Selection example
VIESMANN
12
(cont.)
Continuous output for DHW
heating
from 10 to 60 °C
90 °C
80 °C
27 kW
20 kW
32 kW
24 kW
38 kW
29 kW
28 kW
23 kW
33 kW
25 kW
70 kW
51 kW
82 kW
62 kW
36 kW
28 kW
36 kW
28 kW
45 kW
34 kW
53 kW
44 kW
102 kW
77 kW
121 kW
91 kW
98 kW
78 kW
32 kW
25 kW
36 kW
28 kW
57 kW
43 kW
63 kW
48 kW
82 kW
59 kW
81 kW
62 kW
23 kW
20 kW
23 kW
20 kW
36 kW
27 kW
36 kW
30 kW
74 kW
54 kW
74 kW
54 kW
126 kW
102 kW
203 kW
169 kW
273 kW
228 kW
A Upper indirect coil
Continuous output for DHW heating
from 10 to 45 °C
70 °C
90 °C
80 °C
1
14 kW
28 kW
23 kW
17 kW
33 kW
28 kW
19 kW
42 kW
32 kW
15 kW
32 kW
28 kW
17 kW
41 kW
30 kW
34 kW
80 kW
64 kW
39 kW
97 kW
76 kW
24 kW
24 kW
19 kW
40 kW
32 kW
19 kW
40 kW
32 kW
2
23 kW
53 kW
44 kW
33 kW
70 kW
58 kW
53 kW
123 kW
99 kW
61 kW
136 kW
111 kW
54 kW
109 kW
87 kW
16 kW
37 kW
30 kW
19 kW
40 kW
32 kW
25 kW
62 kW
49 kW
29 kW
71 kW
56 kW
41 kW
93 kW
72 kW
43 kW
96 kW
73 kW
15 kW
31 kW
26 kW
15 kW
31 kW
26 kW
18 kW
42 kW
33 kW
22 kW
47 kW
40 kW
35 kW
80 kW
64 kW
35 kW
80 kW
64 kW
74 kW
92 kW
92 kW
129 kW
158 kW
158 kW
155 kW
176 kW
214 kW
214 kW
208 kW
70 °C
60 °C
50 °C
19 kW
14 kW
22 kW
16 kW
26 kW
18 kW
20 kW
14 kW
23 kW
16 kW
47 kW
33 kW
55 kW
38 kW
25 kW
9 kW
17 kW
9 kW
23 kW
18 kW
32 kW
24 kW
53 kW
28 kW
59 kW
33 kW
77 kW
48 kW
26 kW
22 kW
13 kW
9 kW
24 kW
15 kW
10 kW
38 kW
25 kW
12 kW
44 kW
24 kW
13 kW
52 kW
30 kW
15 kW
56 kW
37 kW
18 kW
20 kW
15 kW
11 kW
20 kW
15 kW
11 kW
25 kW
17 kW
10 kW
30 kW
22 kW
16 kW
45 kW
28 kW
15 kW
45 kW
28 kW
15 kW
92 kW
73 kW
44 kW
121 kW
79 kW
163 kW
108 kW
DHW heating