12.3.13 Network Failure Detection

48
Siemens AB
Security Products
Network Failure Detection allows the IP Camera to ping another IP device (e.g.
NVR, VSS, Video Server, etc.) within the network periodically and generates some
actions in case of network failure occurs, for instance, a Video Server is somehow
disconnected.
Being capable of implementing local recording (through microSD card) when net-
work failure happens, the IP Camera could be a backup recording device for the
surveillance system.
Detection Switch
The default setting for the Detection Switch function is <Off>. Enable the function
by selecting <On>. Users can also activate the function according to the schedule
time that is previously set in the <Schedule> setting page. Select <By schedule>
and click <Please select...> to choose the desired schedule from the drop-down
menu.
Detection Type
Input the IP device address and the period of ping time to ping. The ping time set-
ting range is from 1 to 99 minutes.
Triggered Action (Multi-option)
The administrator can specify alarm actions that will take when network failure is
detected. All options are listed as follows.
Enable Alarm Output
Select the item to enable alarm relay output.
Record Video Clip
Select the item and the alarm-triggered recording will be saved into the microSD
card.
Pre-trigger buffer recording function allows users to check what happened to
cause the trigger. The pre-trigger buffer time range is from 1 to 3 seconds. Select
<Upload for __ sec> to set the recording duration after alarm is triggered. The set-
ting range is from 1 to 99999 seconds. Select <Upload during the trigger active> to
record the triggered video until the trigger is off.
NOTE: Please make sure the local recording (with microSD / SDHC card) is acti-
vated so that this function can be implemented. Refer to
tails.
Send Alarm Message by FTP/E-mail
The administrator can select whether to send an alarm message by FTP and/or E-
mail when an alarm is triggered.
Save
Click the <Save> button to save all the settings mentioned above.