Cameras. Instructions for installation and setup can be found in the Installation Guide. Trademarks SIEMENS CCIC1410 is a trademark of Fire & Security Products GmbH & Co. oHG. Microsoft is a registered trademark and Windows a trademark of Microsoft Corporation.
Ordering data...13 Package contents...13 Description of the equipment ...14 Versions of the camera ...14 Front and rear views of the camera ...15 Pin definitions of input/output (only CCIC1410-LA, -LAW) ...15 Connection method ...16 LED status...16 Hardware reset...17 Installation ...18 Network setup ...18 Internet connection via a router ...19...
Page 4
User interface of the CCIC1410 Homepage ...42 Tabs of the CCIC1410 Homepage...43 The live video window of the CCIC1410 Homepage ...44 Live video window of CCIC1410 Homepage with MPEG4 mode ...44 Live video window of CCIC1410 Homepage with MJPEG mode ...46 Settings for network camera ...47 System ...47...
Refer installation to a qualified electrician. When handling modules that are susceptible to electrostatic discharge, please observe the ESD guidelines. Siemens Building Technologies Fire Safety & Security Products Qualification Activity Has working knowledge Performs only the of computers.
Safety Radio interference with other devices in the environment In France, it is not allowed to use the CCIC1410-LAW outside buildings and on the channels 10 – 13. The unit operates on frequencies that are approved for use in the European Union.
The nature of the hazard is indicated by icons. NOTE Important information. Siemens Building Technologies Fire Safety & Security Products This phenomenon occurs when viewing a very bright object. This is a fixed pattern, which may appear over the entire monitor screen when the camera is operated at high temperatures or in low illumination environments.
Siemens Building Technologies Fire & Security Products GmbH & Co. oHG 76181 Karlsruhe Germany For CCIC1410-L and CCIC1410-LA European Directive 2004/108/EC “Electromagnetic Compatibility” Compliance with the European Directive 2004/108/EC has been proven by testing according to the following standards: Emitted interference: EN 61000-6-3, EN 55022 Class B Resistance to interference: EN 50130-4 European Directive 2006/95/EC “Low-Voltage Directive”...
When used outside the EU, the national regulations for the use of frequencies must be observed. Restrictions for France In France, it is not allowed to use the CCIC1410-LAW out of buildings and on the channels 10 – 13. Siemens Building Technologies Fire Safety &...
Internal microphone Alarm inputs Alarm outputs Motion detection Lens details Lens Angle of view Siemens Building Technologies Fire Safety & Security Products CCIC1410-L CCIC1410-LA 1/4" CMOS sensor 640 (H) x 480 (V) MJPEG / MPEG4 simultaneous dual-streaming VGA (640 x 480) at max. 30 ips Internal 0.4 lx (F2.0)
Page 12
Mechanism Dimensions (W x H x D) Weight Siemens Building Technologies Fire Safety & Security Products 1 x 10/100 base-T Ethernet connection for LAN / WAN IPv4, TCP/IP, HTTP, UPnP, RTSP/RTP/RTCP, IGMP, SMTP, FTP, TelNet, DHCP, NTP, DNS, DDNS, PPPoE...
S54561-C90-A1 CCIC1410-LA S54561-C90-A2 CCIC1410-LAW S54561-C90-A3 Package contents 1 x SIEMENS CCIC1410 IP Camera 1 x Documentation CD 1 x Utilities CD 1 x Installation instruction (English, German) 1 x Installation instruction (French, Spanish, Italian) 1 x Power adapter 1 x Wall/Ceiling bracket...
SIEMENS CCIC1410-LAW also supports built-in 802.11b/g WLAN capability, which prevents tangled cables. Additionally CCIC1410-LA and -LAW come with a pushbutton on the front side for privacy use. The user can manually stop the operation of video monitoring with ease to protect from unwanted observation. This functionality can be activated or deactivated by system administrator only.
Front and rear views of the camera Pin definitions of input/output (only CCIC1410-LA, -LAW) This network camera provides a general input/output terminal block which is used to connect external input / output devices. The pin definitions are described below. Siemens Building Technologies Fire Safety &...
Blinking blue Solid red Blinking green Blinking red Blinking green and red Siemens Building Technologies Fire Safety & Security Products Description Power is being supplied to the camera. The camera is booting up. The camera is trying to obtain an IP address.
Press the reset button continuously until the status LED on the front blinks in red and green simultaneously. Note that all settings will be reset to factory default. Siemens Building Technologies Fire Safety & Security Products Description of the equipment...
Set up the network camera behind a router. Utilize a static IP. Use PPPoE. Siemens Building Technologies Fire Safety & Security Products If you have external devices such as sensors and alarms, connect them to the general I/O terminal block.
Internet connection via a router Before setting up the network camera over the Internet, make sure you have a router, and follow the steps below. Siemens Building Technologies Fire Safety & Security Products Connect your network camera behind a router. The Internet environment is illustrated as below.
Internet connection via PPPoE (Point-to-Point over Ethernet) Choose this connection type if you are connected to the Internet via a DSL Line (see chapter 8.5.1: PPPoE setting). Siemens Building Technologies Fire Safety & Security Products Set up the network camera in the LAN (see chapter 8.5.2).
CCIC1410 Installation Wizard The initial setup of the CCIC1410 network camera is done with the CCIC1410 Installation Wizard. For the first use of the CCIC1410 Installation Wizard, just follow the steps of the Wizard Tool. The CCIC1410 Installation Wizard is a software that helps you installing your CCIC1410 camera.
Page 22
Click Next. The following window will appear. Select an installation directory for this application software. Click Install. The install system will install the CCIC1410 Installation Wizard to your computer, and a progress bar will be displayed on the dialog. 05.2009...
The CCIC1410 Installation Wizard is set up. Click Start > Programs > Siemens > CCIC1410 Install > CCIC1410 Installation Wizard . Use the shortcut on your desktop to open the CCIC1410 Installation Wizard. The user interface of the CCIC1410 Installation Wizard appears. CCIC1410 Installation Wizard...
Select a device for the configuration Siemens Building Technologies Fire Safety & Security Products Open the CCIC1410 Installation Wizard, see chapter 8.2. Select a device in the device list by clicking on it. The three buttons on the left (“Manual Setup”, “Firmware Upgrade”, and “Restore Default”) will not be enabled until at least one device is selected.
When one device is selected in the device list, the Manual Setup button will be enabled. CCIC1410 Installation Wizard will try to connect to the selected device. If the authentication fails, a dialog will pop up asking you for the correct password.
CCIC1410 Installation Wizard Fig. 2 8.4.2 Change host name The Hostname is used for the homepage title of the main page and is displayed as the title in the video window of the main page. The maximum string length is 40 characters or 20 characters in double-byte character systems like Chinese or Japanese.
“PPPoE username” and “PPPoE password” provided by your ISP, and then the server will be set to PPPoE mode rather than LAN mode when the setup is completed. If you do not have the account information, please contact your ISP. The PPPoE setting page appears. CCIC1410 Installation Wizard 05.2009...
CCIC1410 Installation Wizard 8.5.2 LAN setting Siemens Building Technologies Fire Safety & Security Products Fig. 4 PPPoE setting page Enter the account information. Click Next and follow the pages of the Installation Wizard. Open the system settings page (see chapter 8.4.1).
Page 29
DNS server for the device. Siemens Building Technologies Fire Safety & Security Products Network Settings page Enter the information for the LAN setting. Click Next and follow the pages of the Installation Wizard. CCIC1410 Installation Wizard 05.2009...
The Network Settings page appears. On the Network Settings page, click Next. Click Yes. The CCIC1410 Installation Wizard will set the video codec to MPEG-4, and the resolution will be set to 176x144 pixels. You can now configure the wireless connection.
Page 31
The device is connected directly to a host equipped with a wireless adapter in peer-to-peer mode. “Channel” While in Infrastructure mode, the channel will be set automatically to the same channel setting of the selected Access Point. While in Ad-Hoc mode, the CCIC1410 Installation Wizard 05.2009...
Page 32
CCIC1410 Installation Wizard Encrypt You can choose the desired encryption type in the pull-down menu. There are three options: None, WEP and WPA-PSK. – – Siemens Building Technologies Fire Safety & Security Products channel must be set to the same channel for each wireless adapter. The default channel setting depends on the regional settings.
Page 33
64 bits key length: 10 Hex digits or 5 characters. 128 bits key length: 26 Hex digits or 13 characters. Fig. 8 WPA-PSK setting page Click Next and follow the pages of the Installation Wizard. CCIC1410 Installation Wizard 05.2009...
CCIC1410 Installation Wizard Apply settings to selected device After configuring all the settings, the Apply Settings page will show up (Fig. 9). Click Apply to apply the changes to the selected device, or click Back to go back to the previous page and change the setting again.
Page 35
If your server supports the RTSP, a link will be displayed for you to access from QuickTime or other devices supporting RTSP (such as 3GPP Mobile Phone). You can connect to the server via this link. Siemens Building Technologies Fire Safety & Security Products Access Information page CCIC1410 Installation Wizard 05.2009...
Page 36
CCIC1410 Installation Wizard In the Access Information page, you can click on Advanced information to obtain further information. Fig. 11 – – – – – Siemens Building Technologies Fire Safety & Security Products Access Information page – Advanced information Network type:...
Page 37
Bookmark of your browser after adding the link to your favorites Export to desktop will generate an html file on your desktop. You can open this file using your browser and see the access information of this server. HTML file generated on the browser CCIC1410 Installation Wizard 05.2009...
Depending on your network environment, there are four transmission modes of MPEG4 streaming: Siemens Building Technologies Fire Safety & Security Products Open the CCIC1410 Homepage (see chapter 9.1). Choose the Client Settings menu. Choose the stream to be shown in the client. Click Save.
Enter the text that will be put in front of the video file name. Siemens Building Technologies Fire Safety & Security Products Open the CCIC1410 Homepage (see chapter 9.1). Choose the Client Settings menu. Specify the storing destination and file name prefix for the recorded MP4.
Page 40
CCIC1410 Installation Wizard Add date and time suffix to the file name Select this option to add date and time to the file name suffix. Siemens Building Technologies Fire Safety & Security Products 05.2009...
Configuration with the CCIC1410 Homepage The CCIC1410 Homepage helps you viewing your live videos. It is displayed in your web browser. Opening the CCIC1410 Homepage Using the CCIC1410 Installation Wizard Using your Web Browser NOTE For Mozilla Firefox or Netscape users, your browser will use Quick Time to stream the live video.
Configuration with the CCIC1410 Homepage User interface of the CCIC1410 Homepage There are three menus: Live Player Web Configuration Client Settings Siemens Building Technologies Fire Safety & Security Products 05.2009...
Tabs of the CCIC1410 Homepage Snapshot Capture and save still images. The captured images will be displayed in a pop-up window. Right-click the image and choose Save Picture As to save it in JPEG (*.jpg) or BMP (*.bmp) format. Language Choose a language for the displayed interface.
Configuration with the CCIC1410 Homepage The live video window of the CCIC1410 Homepage 9.4.1 Live video window of CCIC1410 Homepage with MPEG4 mode The following window is displayed when the video mode is set to MPEG4: Video title Title and time Siemens Building Technologies Fire Safety &...
Page 45
When the mute function is not activated, move the slider bar to adjust the volume at your local computer. Mute: Turns off the volume at your local computer. Click the Mute button to turn on the audio function. Configuration with the CCIC1410 Homepage 05.2009...
Configuration with the CCIC1410 Homepage 9.4.2 Live video window of CCIC1410 Homepage with MJPEG mode The following window is displayed when the video mode is set to MJPEG. Video title Title and time Siemens Building Technologies Fire Safety & Security Products...
Click this button to record video clips to your computer. Press the Stop recording button to end recording. When you quit the web browser, video recording stops accordingly. Open the CCIC1410 Homepage (see chapter 9.1). Choose the Configuration menu. On the left hand side, choose the menu item System.
(connected to Network), then to blue (privacy function is on). When pressing the privacy button again, the video and audio functionality is switched on again. Open the CCIC1410 Homepage (see chapter 9.1). Choose the Configuration menu. On the left hand side, choose the menu item System.
Page 49
Assign the IP address or domain name of the time server. Leaving the text box blank connects the network camera to the default time servers. Select whether to update the time with the NTP server on an hourly, daily, weekly, or monthly basis. Configuration with the CCIC1410 Homepage 05.2009...
Digital input Digital output Siemens Building Technologies Fire Safety & Security Products Open the CCIC1410 Homepage (see chapter 9.1). Choose the Configuration menu. On the left hand side, choose the menu item System. Define your digital input and digital output settings.
Viewers can only access the main page. Siemens Building Technologies Fire Safety & Security Products Open the CCIC1410 Homepage (see chapter 9.1). Choose the Configuration menu. On the left hand side, choose the menu item Security. Type in the password identically in both text boxes.
Here you can change user’s access rights or delete user accounts. Siemens Building Technologies Fire Safety & Security Products Open the CCIC1410 Homepage (see chapter 9.1). Choose the Configuration menu. On the left hand side, choose the menu item Security.
Network connection settings 9.7.1 Network type Siemens Building Technologies Fire Safety & Security Products Open the CCIC1410 Homepage (see chapter 9.1). Choose the Configuration menu. On the left hand side, choose the menu item Network. Define the settings. Click Save.
Page 54
Configuration with the CCIC1410 Homepage PPPoE Siemens Building Technologies Fire Safety & Security Products Enable UPnP port To access the network camera from the forwarding Internet, select this option to allow the network camera to open ports on the router automatically so that video streams can be sent out from a LAN.
Siemens Building Technologies Fire Safety & Security Products Open the CCIC1410 Homepage (see chapter 9.1). Choose the Configuration menu. On the left hand side, choose the menu item Network. Define the settings.
Configuration with the CCIC1410 Homepage 9.7.3 The FTP server allows the network camera to utilize the SIEMENS CCIC1410 Installation Wizard to upgrade the firmware. The FTP port is set to 21 by default. It can however be assigned any other port number between 1025 and 65535.
MD5 and thus provide better protection against unauthorized accesses. Siemens Building Technologies Fire Safety & Security Products Open the CCIC1410 Homepage (see chapter 9.1). Choose the Configuration menu. On the left hand side, choose the menu item Network. Define the settings.
Page 58
Configuration with the CCIC1410 Homepage The accessibility of the RTSP streaming for the three authentication modes is listed in the following table: O indicates that the authentication mode is supported by the RTSP player. X indicates that the authentication mode is NOT supported by the RTSP player.
SSID is 32 single-byte characters. Siemens Building Technologies Fire Safety & Security Products Open the CCIC1410 Homepage (see chapter 9.1). Choose the Configuration menu. On the left hand side, choose the menu item Wireless LAN. Define the settings, for more information see below.
Page 60
Configuration with the CCIC1410 Homepage Wireless mode: Click on the pull-down menu to select from the following options: Infrastructure: The network camera is connected to the WLAN via an Access Point (default setting). Ad-Hoc: The network camera is connected directly to a host equipped with a wireless adapter in a peer-to-peer environment.
Page 61
Enter a key in either hexadecimal or ASCII format. You can select different key lengths. Acceptable input lengths are as follows: 64 bits key length: 10 Hex digits or 5 characters. 128 bites key length: 26 Hex digits or 13 characters. Configuration with the CCIC1410 Homepage 05.2009...
Page 62
After wireless configurations are completed, click Save and the camera will reboot. Wait until the live. image is reloaded to your browser. For SIEMENS CCIC1410-LAW cameras, you have to unplug the power cable and Ethernet cable from the camera; then re-plug the power cable to the camera. The camera will switch to wireless mode.
List, Delete Allowed List, and Delete Denied List. Siemens Building Technologies Fire Safety & Security Products Open the CCIC1410 Homepage (see chapter 9.1). Choose the Configuration menu. On the left hand side, choose the menu item DDNS. Define the settings.
Page 64
Configuration with the CCIC1410 Homepage Allowed List and Denied List: There are two lists for permission control: the Allowed List and the Denied List. Only those clients whose IP addresses are in the Allowed List and not in the Denied List can access the network camera.
Select to display colourful or black/white video streams. Siemens Building Technologies Fire Safety & Security Products Open the CCIC1410 Homepage (see chapter 9.1). Choose the Configuration menu. On the left hand side, choose the menu item Audio and video. Define the settings.
Page 66
Configuration with the CCIC1410 Homepage Power line frequency: Select the appropriate power line frequency for your location to eliminate image flickering. Note that after the power line frequency is changed, it is required to disconnect and reconnect the power cord of the network camera in order for the new setting to take effect.
Page 67
You can resize and drag-drop the window, which should be at least twice the size of the object (height and width) you want to cover. Enter a descriptive window name and click Save for the settings to take effect. Select Enable privacy mask to enable this function. Configuration with the CCIC1410 Homepage 05.2009...
Page 68
Configuration with the CCIC1410 Homepage NOTE Up to 5 privacy mask windows can be set in the same screen. If you want to delete a window, click on the ‘x’ in the upper right-hand corner of the window to close the window.
Page 69
176x144 good 176x144 good 320x240 good 320x240 good 640x480 good Siemens Building Technologies Fire Safety & Security Products Configuration with the CCIC1410 Homepage Streaming protocol Image rate / ips JPEG JPEG JPEG JPEG JPEG JPEG JPEG JPEG JPEG JPEG...
Page 70
Configuration with the CCIC1410 Homepage Resolution Video quality 640x480 good 176x144 excellent 176x144 excellent 320x240 excellent 320x240 excellent 640x480 excellent 640x480 excellent 176x144 medium 176x144 medium 320x240 medium 320x240 medium 640x480 medium 640x480 medium 176x144 good 176x144 good 320x240 good...
Audio type: – – Siemens Building Technologies Fire Safety & Security Products Open the CCIC1410 Homepage (see chapter 9.1). Choose the Configuration menu. On the left hand side, choose the menu item Audio and video. Define the settings. Click Save.
– Siemens Building Technologies Fire Safety & Security Products Open the CCIC1410 Homepage (see chapter 9.1). Choose the Configuration menu. On the left hand side, choose the menu item Motion Detection. Click New to add a new motion detection window.
Page 73
A green bar indicates that even though motions are detected, the event will not be triggered because the image variations are still below the defined threshold. Siemens Building Technologies Fire Safety & Security Products Mark the checkbox Enable motion detection to enable this function. Configuration with the CCIC1410 Homepage 05.2009...
Siemens Building Technologies Fire Safety & Security Products Open the CCIC1410 Homepage (see chapter 9.1). Choose the Configuration menu. On the left hand side, choose the menu item Application. Choose the desired settings.
Page 75
An event is an action initiated by a user-defined trigger source; it is the causal arrangement of the following three elements: Trigger Event Schedule Action Siemens Building Technologies Fire Safety & Security Products Configuration with the CCIC1410 Homepage 05.2009...
Page 76
Configuration with the CCIC1410 Homepage Trigger: Also referred to as the cause or stimulus, defines when to trigger the event. The trigger source can be configured to use the network camera’s built-in motion detection mechanism or external digital input devices. There are four choices of...
Page 77
A total of five media settings can be configured. Media name: Enter a descriptive name for the media. Media Type: There are three choices of media types available: Snapshot Video clip System log Siemens Building Technologies Fire Safety & Security Products Configuration with the CCIC1410 Homepage 05.2009...
Page 78
Configuration with the CCIC1410 Homepage Media Type: Snapshot: – Select to send snapshots when a trigger is activated. Select whether to use snapshots from stream 1 or stream 2. The network camera has a buffer area; it temporarily holds data up to a certain limit.
In this page, you can specify where the notification messages will be sent when a trigger is activated. A total of five server settings can be configured. Siemens Building Technologies Fire Safety & Security Products Configuration with the CCIC1410 Homepage 05.2009...
Page 80
Configuration with the CCIC1410 Homepage Server name: Enter a descriptive name for the server. There are four server types available: Email – – HTTP – Alarm Sever – Server Type: E-mail: – Select to send the media via email when a trigger is activated.
Before utilizing this feature, it is recommended to install a Siemens Building Technologies Fire Safety & Security Products Server address: Server port: User name: Password: Remote folder name: Passive mode: URL: User name: Password: Alarm Server IP Address: Alarm Server Port Number: Configuration with the CCIC1410 Homepage 05.2009...
Siemens Building Technologies Fire Safety & Security Products Open the CCIC1410 Homepage (see chapter 9.1). Choose the Configuration menu. On the left hand side, choose the menu item System log.
Two settings can be excluded. Siemens Building Technologies Fire Safety & Security Products Open the CCIC1410 Homepage (see chapter 9.1). Choose the Configuration menu. On the left hand side, choose the menu item View parameters. The parameter list appears.
Export daylight saving time configuration file Siemens Building Technologies Fire Safety & Security Products Open the CCIC1410 Homepage (see chapter 9.1). Choose the Configuration menu. On the left hand side, choose the menu item Maintenance. In the Restore section, mark/unmark the checkboxes for Network Type and Daylight saving time.
Page 85
Fire Safety & Security Products In the example below, the DST begins each year at 2:00 a.m. on the last Sunday in March and ends at 3:00 a.m. on the last Sunday in October. Configuration with the CCIC1410 Homepage 05.2009...
Page 86
Configuration with the CCIC1410 Homepage Upload Daylight Saving Time Configuration File Siemens Building Technologies Fire Safety & Security Products In the Upload section, click Browse… and specify the XML file. If the incorrect date and time is assigned, you will see a warning message when uploading the file to the network camera.
Double click a device in the device list. The CCIC1410 Homepage appears. Choose the menu item Live Player Web. The Live Player shows the stream of the CCIC1410 network camera. Open the CCIC1410 Homepage (see chapter 9.1). Choose the menu item Live Player Web.
To access motion jpeg stream 1 using the cgi-command, type: http://<ipaddress>:<80>/ cgi-bin/<liveimage> See also chapter 9.7.2. Siemens Building Technologies Fire Safety & Security Products The live video will be displayed on your player. For more information on how to configure the RTSP access name, please refer to RTSP Streaming setting.
Intra image period Video quality (constant bit rate) Audio type (GSM-AMR) Siemens Building Technologies Fire Safety & Security Products As most players on 3GPP mobile phones do not support RTSP authentication, make sure the authentication of RTSP streaming is disabled.
Using the CCIC1410 Installation Wizard NOTE The CCIC1410 Installation Wizard allows you to upgrade several devices (of the same model) at the same time. If you select different models, then the Firmware Upgrade button will be disabled. Siemens Building Technologies Fire Safety &...
Page 91
Siemens Building Technologies Fire Safety & Security Products In the Selected devices information section, you will see tabs with IP addresses if more than one device was selected. Firmware version: The version number of the selected firmware. Use the Select firmware button to select the file that you want to upload to the selected device(s).
Page 92
Siemens Building Technologies Fire Safety & Security Products When you have selected a file, the CCIC1410 Installation Wizard will check whether the file you selected is correct. If it is the correct version, then the package information will display the information about the file and enable the Start upgrade button.
Page 93
Fig. 14 Siemens Building Technologies Fire Safety & Security Products Upgrade done Click OK to finish the upgrade. The upgrade is done. Upgrade firmware 05.2009...
DTS Siehe Daylight saving time Host name 26, Siehe network camera Change ~ 26 HTTP 39 fixed ~ 29 LAN setting 28 Siemens Building Technologies Fire Safety & Security Products Network camera name of ~ 47 Network setting See LAN setting PPPoE password 27...