Fan Blank; Hot-Swap Fan - HP ProLiant DL120 Gen9 Maintenance And Service Manual

Hide thumbs Also See for ProLiant DL120 Gen9:
Table of Contents

Advertisement

If one fan rotor fails, the system continues to operate without redundancy. This condition is indicated
o
by a flashing amber Health LED.
If two fan rotors fail, the system shuts down.
o
The minimum fan requirement to make this server bootable is three fans.
o

Fan blank

WARNING:
internal system components to cool before touching them.
To remove the component:
Power down the server (on page 29).
1.
Remove all power:
2.
Disconnect each power cord from the power source.
a.
Disconnect each power cord from the server.
b.
Disconnect all peripheral cables and power cords from the rear panel.
3.
Do one of the following:
4.
Extend the server from the rack (on page 30).
o
Remove the server from the rack (on page 30).
o
Remove the access panel
5.
Remove the air baffle (on page 31).
6.
Remove the fan blank.
7.
CAUTION:
all bays are populated with either a component or a blank.
To replace the component, reverse the removal procedure.

Hot-swap fan

To reduce the risk of personal injury from hot surfaces, allow the drives and the
("Access
panel" on page 36).
To prevent improper cooling and thermal damage, do not operate the server unless
Removal and replacement procedures 45