Hp 800-W/900-W Gold Ac Power Input Module - HP ProLiant DL120 Gen9 Maintenance And Service Manual

Hide thumbs Also See for ProLiant DL120 Gen9:
Table of Contents

Advertisement

Remove the power supply.
6.
To replace the component, reverse the removal procedure.

HP 800-W/900-W Gold AC Power Input Module

WARNING:
internal system components to cool before touching them.
CAUTION:
precautions before beginning any installation, removal, or replacement procedure. Improper
grounding can cause electrostatic discharge.
To remove the component:
Power down the server (on page 29).
1.
Access the product rear panel.
2.
To reduce the risk of personal injury from hot surfaces, allow the drives and the
To prevent damage to electrical components, take the appropriate anti-static
Removal and replacement procedures 73

Advertisement

Table of Contents
loading

Table of Contents