Kenwood TM-V71A Service Manual page 58

144/430 (440) mhz fm dual bander
Hide thumbs Also See for TM-V71A:
Table of Contents

Advertisement

TM-V71A/V71E
Item
Condition
3) Frequency: 435.000MHz E,M4
Frequency: 444.000MHz K
SSG output: –53dBm (501µV)
AF V.M: 0dB
4) SSG DEV: OFF
• Band B
5) Frequency: 145.250MHz E,M4
Frequency: 146.250MHz K
SSG output: –53dBm (501µV)
AF V.M: 0dB
6) SSG DEV: OFF
7) Frequency: 435.000MHz E,M4
Frequency: 444.000MHz K
SSG output: –53dBm (501µV)
AF V.M: 0dB
8) SSG DEV: OFF
14. Squelch
1) Frequency: 145.250MHz E,M4
Check
Frequency: 146.250MHz K
Band A
SSG output: OFF
• 144MHz band
Set to the point where noise
will be muted by turning the
SQL knob (Band A).
2) SSG output: –126dBm (0.11µV)
SSG MOD: 1kHz
SSG DEV: 3kHz
AF output: 0.63V/8Ω
• 430MHz band 3) Frequency: 435.250MHz E,M4
Frequency: 444.250MHz K
SSG output: OFF
Set to the point where noise
will be muted by turning the
SQL knob (Band A).
4) SSG output: –126dBm (0.11µV)
SSG MOD: 1kHz
SSG DEV: 3kHz
AF output: 0.63V/8Ω
Band B
5) Frequency: 145.250MHz E,M4
• 144MHz band
Frequency: 146.250MHz K
SSG output: OFF
Set to the point where noise
will be muted by turning the
SQL knob (Band B).
6) SSG output: –126dBm (0.11µV)
SSG MOD: 1kHz
SSG DEV: 3kHz
AF output: 0.63V/8Ω
58
ADJUSTMENT
Measurement
Test-
Unit
Terminal
Unit
equipment
SSG
Oscilloscope
Distortion
meter
AF V.M
Dummy load
SSG
Rear
ANT
Oscilloscope
panel
EXT.SP
Adjustment
Specifi cations / Remarks
Parts
Method
Check
–43dB or less
Check
–43dB or less
Check
–43dB or less
Check
SQL knob (Band A) position:
8:00~11:00
BUSY icon disappear.
Squelch open.
BUSY icon appears and
S-meter display does not
appear.
SQL knob (Band A) position:
8:00~11:00
BUSY lights off
Squelch open.
BUSY icon appears and
S-meter display does not
appear
SQL knob (Band B) position:
8:00~11:00
BUSY icon disappear.
Squelch open.
BUSY icon appears and
S-meter display does not
appear

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tm-v71e

Table of Contents