Chapter 5 System Settings and Display
5.3 System Settings > set power-synchronization
set power-synchronization
This command configures the way in which the shutdown function interacts with the external sensor.
■
Syntax
set power-synchronization [-rcil {enable|disable}] [-auto-power {enable | disable}]
[-resume-power {enable | disable}] [-cm {0 | 1 | all | none}] [-shutdown-time
[-preset { power-sync | pman | manual}] [-power-fail-signal { positive | negative }]
[-low-battery-signal { positive | negative }] [-ups-shutdown-signal { disable | positive | negative }]
■
Parameter
-rcil
-auto-power
-resume-power
-cm
Optional. This parameter specifies whether the power synchronization setting using the RCIL.
enable
Enabled.
disable
Disabled.
Optional. If "enable" is specified, the system power is turned on when a power supply is
detected. The default value is set to disable.
enable
Enabled.
disable
Disabled. (Default)
Optional. If "enable" is specified, the system power is turned on when a power supply is
detected after the ETERNUS DX is shut down due to a power outage. The default value is set to
disable.
enable
Enabled.
disable
Disabled. (Default)
Optional. This parameter specifies which controller module connects to the external sensor.
The connection method conforms to the PWC port (RS-232C standard). If omitted, the existing
setting is not changed.
0
Controller module #0
1
Controller module #1
all
Both controller module #0 and controller module #1
none
No connection. If selected, only "-auto-power" and "-resume-power" from the
parameters that follow can be selected.
ETERNUS CLI User's Guide
Copyright 2014 FUJITSU LIMITED
620
shutdown_time
]
P2X0-1210-05ENZ0