Chapter 5 System Settings and Display
5.3 System Settings > show power-synchronization
show power-synchronization
This command displays the settings that control how the shutdown function interacts with the external
sensor.
■
Syntax
show power-synchronization
■
Parameter
No parameters.
■
Output
RCIL
Auto Power
Resume Power
Controller Module #0
Controller Module #1
Waiting Time to Shutdown
Type
Power Fail Signal
Low Battery Signal
UPS Shutdown Signal
The setting of the power control function that uses an RCIL interface
The setting to turn the system power on when power is supplied
The setting to turn the system power on when power is supplied after the ETERNUS DX is
shutdown due to a power outage
Indicates whether the CM#0 is connected to the power synchronized device.
Indicates whether the CM#1 is connected to the power synchronized device.
The time that starts the ETERNUS DX shutdown when a power outage signal is received from
an external sensor device
The reset interface (Power Synchronized Unit, PMAN, or manual). In this output, the preset
interface is displayed if the same setup as the preset is set by manual setup.
The signal polarity that controls the input power outage signal when a power supply fails and
power is not provided
The signal polarity that controls the battery voltage low signal when the battery usage of a
UPS is low
The signal polarity that controls the UPS output stop signal when the shutdown is complete
ETERNUS CLI User's Guide
Copyright 2014 FUJITSU LIMITED
618
P2X0-1210-05ENZ0