Pneumatic Connection; Electrical Connection; Check Rotation Direction - Bosch TCE 4225 Original Instructions Manual

Table of Contents

Advertisement

en
30 | TCE 4225 | Initial commissioning
i
For safe and ergonomic use of the TCE 4225 it is
recommended to leave a minimum of 500 mm space
from surrounding walls.
Warning - tilting danger!
During the functioning of TCE 4225 conside-
rable forces are exerted.
The TCE 4225 has to be fixed in at least 3
points on the floor (screw holes see chap.
4.2).
i
In each screw hole are placed shock absorbers to
reduce vibrations to the minimum.
5. Pre-arrange a suitable lubricator in the lubricator
holder bulb.
4.3

Pneumatic connection

1. Connect the TCE 4225 to the compressed air supply
unit.
2. Adjust to a pressure between 8 and 12 bar.
« Pull the red knurled screw (pressure reducing val-
ve) fi rst upwards and then twist it to adjust ope-
rating pressure.
« Check pressure on the manometer.
|
1 695 105 431
2010-02-16
4.4

Electrical connection

1. Check the correspondence of the mains tension and
the tension shown on the identification tag.
2. Ask a qualified electrician to mount a connection
plug for single-phase or (depending on the tension
you have ordered ) three-phase current (see the
electrical connections diagram inside the electrical
panel).
i
The costs of arranging a mains protection device for
the plug are borne by the customer.
3. Protect the TCE 4225 according to specific national
rules.
4.5

Check rotation direction

!
For a correct functioning of TCE 4225 it is extremely
important that, when the locking flange pedal shown
in Fig. 2 (1) is pressed, the locking flange (Fig. 2)
rotates clockwise.
1
Fig. 2:
Check rotation direction.
Robert Bosch GmbH

Advertisement

Table of Contents
loading

Table of Contents