GE C70 Instruction Manual page 591

Capacitor bank protection and control system ur series
Hide thumbs Also See for C70:
Table of Contents

Advertisement

APPENDIX B
Table B–10: MODBUS MEMORY MAP (Sheet 63 of 65)
ADDR
REGISTER NAME
D35E
IEC 61850 GGIO2.CF.SPCSO63.ctlModel Value
D35F
IEC 61850 GGIO2.CF.SPCSO64.ctlModel Value
Remote Device Status (Read Only) (16 modules)
D360
Remote Device 1 StNum
D362
Remote Device 1 SqNum
D364
...Repeated for Remote Device 2
D368
...Repeated for Remote Device 3
D36C
...Repeated for Remote Device 4
D370
...Repeated for Remote Device 5
D374
...Repeated for Remote Device 6
D378
...Repeated for Remote Device 7
D37C
...Repeated for Remote Device 8
D380
...Repeated for Remote Device 9
D384
...Repeated for Remote Device 10
D388
...Repeated for Remote Device 11
D38C
...Repeated for Remote Device 12
D390
...Repeated for Remote Device 13
D394
...Repeated for Remote Device 14
D398
...Repeated for Remote Device 15
D39C
...Repeated for Remote Device 16
Contact Outputs (Read/Write Setting) (64 modules)
D3E0
Contact Output 1 Name
D3E6
Contact Output 1 Operation
D3E8
Contact Output 1 Seal In
D3EA
Latching Output 1 Reset
D3EC
Contact Output 1 Events
D3ED
Latching Output 1 Type
D3EE
Reserved
D3EF
...Repeated for Contact Output 2
D3FE
...Repeated for Contact Output 3
D40D
...Repeated for Contact Output 4
D41C
...Repeated for Contact Output 5
D42B
...Repeated for Contact Output 6
D43A
...Repeated for Contact Output 7
D449
...Repeated for Contact Output 8
D458
...Repeated for Contact Output 9
D467
...Repeated for Contact Output 10
D476
...Repeated for Contact Output 11
D485
...Repeated for Contact Output 12
D494
...Repeated for Contact Output 13
D4A3
...Repeated for Contact Output 14
D4B2
...Repeated for Contact Output 15
D4C1
...Repeated for Contact Output 16
D4D0
...Repeated for Contact Output 17
D4DF
...Repeated for Contact Output 18
D4EE
...Repeated for Contact Output 19
D4FD
...Repeated for Contact Output 20
D50C
...Repeated for Contact Output 21
D51B
...Repeated for Contact Output 22
D52A
...Repeated for Contact Output 23
D539
...Repeated for Contact Output 24
D548
...Repeated for Contact Output 25
D557
...Repeated for Contact Output 26
GE Multilin
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
C70 Capacitor Bank Protection and Control System
RANGE
UNITS
STEP
0 to 2
---
1
0 to 2
---
1
---
1
---
1
---
---
---
---
1
---
1
---
1
0 to 1
---
1
0 to 1
---
1
---
---
---
B.4 MEMORY MAPPING
FORMAT
DEFAULT
F001
1
F001
1
F003
0
F003
0
F205
"Cont Op 1"
F300
0
F300
0
F300
0
F102
1 (Enabled)
F090
0 (Operate-
dominant)
F001
0
B-71
B

Advertisement

Table of Contents
loading

Table of Contents