5 SETTINGS
Table 5–15: C70 FLEXLOGIC OPERANDS (Sheet 8 of 10)
OPERAND TYPE
OPERAND SYNTAX
ELEMENT
TRIP BUS 1 PKP
Trip bus
TRIP BUS 1 OP
TRIP BUS 2 to 6
ELEMENT:
VOLT DIF 1 STG1A PKP
Voltage differential
VOLT DIF 1 STG1B PKP
VOLT DIF 1 STG1C PKP
VOLT DIF 1 STG2A PKP
VOLT DIF 1 STG2B PKP
VOLT DIF 1 STG2C PKP
VOLT DIF 1 STG3A PKP
VOLT DIF 1 STG3B PKP
VOLT DIF 1 STG3C PKP
VOLT DIF 1 STG4A PKP
VOLT DIF 1 STG4B PKP
VOLT DIF 1 STG4C PKP
VOLT DIF 1 PKP A
VOLT DIF 1 PKP B
VOLT DIF 1 PKP C
VOLT DIF 1 PKP
VOLT DIF 1 DPO
VOLT DIF 1 STG1A OP
VOLT DIF 1 STG1B OP
VOLT DIF 1 STG1C OP
VOLT DIF 1 STG2A OP
VOLT DIF 1 STG2B OP
VOLT DIF 1 STG2C OP
VOLT DIF 1 STG3A OP
VOLT DIF 1 STG3B OP
VOLT DIF 1 STG3C OP
VOLT DIF 1 STG4A OP
VOLT DIF 1 STG4B OP
VOLT DIF 1 STG4C OP
VOLT DIF 1 OP A
VOLT DIF 1 OP B
VOLT DIF 1 OP C
VOLT DIF 1 OP
VOLT DIF 2 to 3
FIXED OPERANDS
Off
On
INPUTS/OUTPUTS:
Cont Ip 1
Contact inputs
Cont Ip 2
Cont Ip 1
Cont Ip 2
Cont Ip 96
Cont Ip 96
INPUTS/OUTPUTS:
Cont Op 1 Closed
Contact outputs
Cont Op 1 IOn
Cont Op 1 VOn
Cont Op 1 VOff
Cont Op 2 to 64
INPUTS/OUTPUTS
DIRECT INPUT 1 On
Direct inputs
DIRECT INPUT 32 On
INPUTS/OUTPUTS:
RemDPS Ip 1 BAD
Remote double-
RemDPS Ip 1 INTERM
point status inputs
RemDPS Ip 1 OFF
RemDPS Ip 1 ON
REMDPS Ip 2 to 5
INPUTS/OUTPUTS:
REMOTE INPUT 1 On
Remote inputs
REMOTE INPUT 2 On
REMOTE INPUT 3 On
REMOTE INPUT 32 On
GE Multilin
OPERAND DESCRIPTION
Asserted when the trip bus 1 element picks up
Asserted when the trip bus 1 element operates
Same set of operands as shown for TRIP BUS 1
Voltage differential element 1 picked up in phase A of stage 1
Voltage differential element 1 picked up in phase B of stage 1
Voltage differential element 1 picked up in phase C of stage 1
Voltage differential element 1 picked up in phase A of stage 2
Voltage differential element 1 picked up in phase B of stage 2
Voltage differential element 1 picked up in phase C of stage 2
Voltage differential element 1 picked up in phase A of stage 3
Voltage differential element 1 picked up in phase B of stage 3
Voltage differential element 1 picked up in phase C of stage 3
Voltage differential element 1 picked up in phase A of stage 4
Voltage differential element 1 picked up in phase B of stage 4
Voltage differential element 1 picked up in phase C of stage 4
Voltage differential element 1 picked up in phase A
Voltage differential element 1 picked up in phase B
Voltage differential element 1 picked up in phase C
Voltage differential element 1 picked up
Voltage differential element 1 dropped out
Voltage differential element 1 operated in phase A of stage 1
Voltage differential element 1 operated in phase B of stage 1
Voltage differential element 1 operated in phase C of stage 1
Voltage differential element 1 operated in phase A of stage 2
Voltage differential element 1 operated in phase B of stage 2
Voltage differential element 1 operated in phase C of stage 2
Voltage differential element 1 operated in phase A of stage 3
Voltage differential element 1 operated in phase B of stage 3
Voltage differential element 1 operated in phase C of stage 3
Voltage differential element 1 operated in phase A of stage 4
Voltage differential element 1 operated in phase B of stage 4
Voltage differential element 1 operated in phase C of stage 4
Voltage differential element 1 operated in phase A
Voltage differential element 1 operated in phase B
Voltage differential element 1 operated in phase C
Voltage differential element 1 operated
Same set of operands as shown for VOLT DIF 1
Logic = 0. Does nothing and may be used as a delimiter in an equation list;
used as 'Disable' by other features.
Logic = 1. Can be used as a test setting.
On
(will not appear unless ordered)
On
(will not appear unless ordered)
Off
(will not appear unless ordered)
Off
(will not appear unless ordered)
On
(will not appear unless ordered)
Off
(will not appear unless ordered)
Contact output is closed
Current is flowing through the contact
Voltage exists across the contact (present for contact outputs equipped with
monitoring)
Voltage exists across the contact (present for contact outputs equipped with
monitoring)
Same set of operands as shown for Cont Op 1
Flag is set, logic=1
Flag is set, logic=1
Asserted while the remote double-point status input is in the bad state
Asserted while the remote double-point status input is in the intermediate
state
Asserted while the remote double-point status input is off
Asserted while the remote double-point status input is on
Same set of operands as per REMDPS 1
Flag is set, logic=1
Flag is set, logic=1
Flag is set, logic=1
Flag is set, logic=1
C70 Capacitor Bank Protection and Control System
5.5 FLEXLOGIC