Sign In
Upload
Manuals
Brands
ZIEHL-ABEGG Manuals
DC Drives
ZETADYN 3BF
ZIEHL-ABEGG ZETADYN 3BF Frequency Drives Manuals
Manuals and User Guides for ZIEHL-ABEGG ZETADYN 3BF Frequency Drives. We have
3
ZIEHL-ABEGG ZETADYN 3BF Frequency Drives manuals available for free PDF download: Original Operating Instructions, Technical Information, Brief Instructions
ZIEHL-ABEGG ZETADYN 3BF Original Operating Instructions (204 pages)
Brand:
ZIEHL-ABEGG
| Category:
DC Drives
| Size: 3.82 MB
Table of Contents
Table of Contents
2
1 General Information
8
Validity
8
Structure of the Operating Instructions
8
Target Group
8
Structure of Operating Instructions
8
Exclusion of Liability
8
Copyright
9
Explanation of Symbols and Designators
9
2 Safety Instructions
9
General
9
Intended Use
9
Pictographs
9
Product Safety
10
Requirements Placed on the Personnel / Due Diligence
10
Commissioning
10
Working on Device/Hazards through Residual Voltage
10
Modifications / Interventions in the Device
11
Operator's Obligation of Diligence
11
Employment of External Personnel
11
3 Product Overview
12
Application
12
Functional Description
12
Service & Maintenance
12
Transport
12
Storage Duration
13
Disposal & Recycling
13
4 Mechanical Installation
13
General Notes
13
Switch Cabinet Installation
13
Dimensions / Minimum Clearances
14
5 Electrical Installation
16
EMC-Compatible Installation
16
Cables Motor / Brake Resistor
17
Cable Length
17
Contacting the Shielding on the Frequency Converter
18
Contacting the Shielding on the Motor
18
Contacting the Shielding on the Brake Resistor
19
Control Cables
19
Device Set-Up / Position of Connection Terminals
20
Wiring
21
Cable Laying ZETADYN 3C011 to ZETADYN 3C032
21
Cable Laying ZETADYN 3C040 up to ZETADYN 3C074
21
Movable EMC Cable Screw Glands
22
Protective Ground Connection
22
Mains Connection (X1)
23
Network Form
23
Cable Cross Section
23
Mains Fuse
23
Type of Cable
23
Connection
23
Line Reactor-Radio Interference Filter
24
Residual Current Operated Device (RCCB)
24
Control Transformer in the Mains Feed Line
25
Motor Connection (X2)
25
Cable Cross Section
25
Type of Cable
25
Cable Length
25
Connection
26
Motor Temperature Monitoring (X-MT)
27
Brake Resistor (X 2)
28
Digital Inputs (X-IN)
29
Connection with External Power Supply
30
Connection with Internal Power Supply
30
Technical Data
31
Terminal Assignment X-IN
31
Binary Traveling Speed Default
32
Digital Outputs X-OUT
32
Connection X-OUT
32
Digital Output X-BC:PWM
32
Connection PWM
33
Technical Data
33
Terminal Assignment X-OUT
33
DCP / CAN Interface (X-DCP, X-CAN)
34
Dcp
34
Canopenlift
34
Power Feedback Unit Connection
35
Encoder Connection Asynchronous Motors (X-ENC8 X-ENC15)
35
Technical Data X-ENC8, X-ENC9 and X-ENC15
36
Terminal Assignment X-ENC8
36
Pin Assignment X-ENC9 / X-ENC15
36
Encoder Connection to Terminal X-ENC8
36
Encoder Connection Synchronous Motors (X-ENC15)
37
Technical Data X-ENC15
37
Pin Assignment X-ENC15 for Absolute Value Encoder with Endat/Ssi Interface
38
Pin Assignment X-ENC15 for Absolute Value Encoder Type ERN1387 (Not for ZETADYN 3C-MRL)
38
Artificial Encoder (X-ENCO)
39
Technical Data X-ENCO
39
Connection X-ENCO
39
External 24V Power Supply (X-EXT)
39
Technical Data
39
Connection X-EXT
40
Motor Contactors
40
Activation of the Motor Contactors (X-K)
40
Technical Data Motor Contactors
41
Internal Monitoring of the Motor Contactors (X-CO)
41
Technical Data Internal Contactor Monitoring
41
External Monitoring of the Motor Contactors (X-K)
42
Technical Data Auxiliary Contacts
42
Assignment Connection Terminal X-K Without Integrated Brake Contactors
43
Assignment Connection Terminal X-K with Integrated Brake Contactors
43
Brakes
43
Brake Release Monitoring (X-BR)
43
Connection X-BR
44
Triggering of the Brakes
44
Integrated Brake Contactors (Optional)
45
Technical Data Brake Contactors
46
Emergency Power Suply
46
Assignment of Terminals X3 and X-K in Integrated Brake Actuation
47
Connection Suggestion ZETADYN 3CA (Asynchronous Motor)
49
Connection Suggestion ZETADYN 3CS (Synchronous Motor)
50
6 Accessories
53
Operating Terminal ZETAPAD
53
Mounting / Fastening
53
Dimensions
53
Connection
53
7 Operation and Parameterising
54
Possibilities for Operation and Configuration
54
Operating Terminal ZETAPAD
54
Remote Control Via ZETAMON Software
54
Remote Control Via the Elevator Controller Display
54
Menu Navigation
54
Control Key Functions
55
Menu and Parameter Navigation
55
The Different Operating Levels
55
Meaning of the Arrows Appearing in the Display
56
Entering Numerical Values
56
Continuous Change of a Parameter Value
56
Changing Individual Digits
56
8 Start-Up
57
Preconfigured Inverter
57
Switching on the Frequency Inverter
58
Parameterization of the Frequency Inverter
58
Automatic Operating-Curves Default
61
Setting the Switch-Off Points
62
Cut-Off Points for Travel Speed V_3
62
Cut-Off Points for Travel Speed V_2
62
Cut-Off Points for Travel Speed V_1
62
Carrying out the First Test Run
63
Optimisation of the Startup and Drive Behaviour
63
9 Serial Communication
65
DCP (Drive Control & Position)
65
Electrical Connection
65
The Various DCP Protocols
65
Configuring in DCP Mode
67
Activating the DCP Interface
67
Setting the DCP-Leveling Behavior
67
Canopenlift
68
Start-Up the CAN-Interface
68
Bus-Cable
68
Frequency Inverter
68
Information for Start-Up
68
Wiring
68
Activating the Interface
69
Electrical Connection
69
Operation Modes
69
Command- and Statusbits of the Recorder
70
Parameter
71
Network Management Status
71
Parameter Settings
71
10 Parameter List
72
Basic-Level
72
Startup Menu
72
Advanced-Level
76
LCD & Password Menu
76
Motor Name Plate Menu
77
Encoder & BC Menu
78
Installation Menu
79
Control System Menu
80
Monitoring Menu
85
Start Menu
87
Acceleration Menu
88
Travel Menu
88
Decelerating Menu
89
Stop Menu
90
Controller Menu
90
Parameter Set 2 Menu
91
Statistic Menu
92
Memory Card Menu
93
MMC-Recorder Menue
94
Encoder Adjustment Menu
95
Safety Gear Menu
96
HW-Ident. Menu
96
Power Section Menu
97
Menu Checks
97
CAN Menu
97
ZA-Intern Menu
98
INFO Menu
99
11 Travel Options
107
Normal Travel
107
Start-Up and Acceleration
107
Optimizing Start up Behavior
108
Damping the Start-Up Jerk
109
Start-Up Variations
109
Optimizing the Acceleration
110
Traveling Speed Defaults
111
Distance-Dependent Deceleration
111
Normal Stop During Path Dependent Deceleration
112
Arch Travel with Path-Dependent Deceleration
113
Time-Dependent Deceleration
114
Deceleration with Reached Traveling Speed
114
Deceleration When Traveling Speed Has Not Been Reached
115
Optimizing Deceleration
116
Crawl Path Optimization
117
Optimizing Stopping
118
Optimizing the Step Alignment
119
Direct Leveling
120
Readjustment
121
Operation in Idle
121
Fast-Start
122
Modulation
122
Monitoring Functions for Quickstart
123
12 Emergency Evacuation
124
Evacuation with 1-Phase Mains Supply 230V AC
124
Parameterisation
125
Evacuation with UPS
126
Evacuation through UPS with Optimum Power
126
Evacuation through UPS with Minimum Power
127
Parameterisation
127
Improving the Positioning
129
Parameterisation
129
Connection Diagram for UPS to ZETADYN 3
130
Emergency Evacuation by Opening the Brakes
131
Monitor Function
131
13 Error Diagnosis
132
Travel Abort and Acknowledgement During Malfunctions
132
Travel Abort
132
Acknowledgement
132
Light Emitting Diodes
132
Software Update
133
Readout the Error Memory
133
Delete Error Memory
134
Error List
135
Block Function
135
Masc-Funktion
135
Notes 0Xx
135
Error 1Xx
136
Error 2Xx
136
Error 3Xx
138
Error 4Xx
140
Error 5Xx
141
Error 7Xx
145
Error 8Xx
145
Error 9Xx
146
Information Texts
148
Operating Conditions of the Inverter
149
Frequent Startup Problems
150
Automatic Parameter Check (APC)
150
Automatic Parameter Diagnostics (APD)
150
14 Energy Saving
151
Stand-By Function Frequency Converter
151
Standby 1
151
Activation of Stand-By 1 Mode
151
Activation of Stand-By 2 Mode
151
Standby 2
151
Power Feedback Unit (PFU)
152
Activation of Stand-By Mode
152
Stand-By Operation of the Power Feedback Unit
152
Electrical Connection Stand-By Mode
153
Power Feedback Unit in Connection with Automatic Emergency Evacuation
153
15 Special Functions
155
Changing the Clock Frequency
155
Fixed Presetting of the Clock Frequency (Menu Power Sectionl/M_Pwm=Fix F_Pwm)
155
Automatic Adjustment if the Clock Frequency (Menu Power Sectionl/M_Pwm=Auto)
155
Encoder Offset-Alignment
155
Load-Free Alignment SSI-Encoder
156
Load-Free Alignment Endat-Encoder
159
Checking the Load-Free Alignment of the SSI- & Endat-Encoders
161
Rotary Encoder Calibration with Closed Brake
163
Alignment Absolute Encoder Type ERN1387
165
Error Messages During Encoder Offset Alignment
166
Safety Brake
167
Reset
169
Memory Card
170
Software Update
170
Software Update with the Zapad Operating Terminal
170
Software Update Without the ZETAPAD Operating Terminal
171
Error Flash Code During a Software Update
172
Saving Parameters
172
Loading Parameters
173
Saving Parameters Lists, Printer Lists and Error Lists
173
Performing Measurements
174
Saving Configurations
174
Loading Configurations
175
Checking the Motor Phases
176
Field Weakening
176
Encoder-Less Operation (Open-Loop)
177
Activate Operating Mode for Operation Without Encoder
177
Parameter for Open-Loop-Operation
178
Current-Control
179
Functions with Open-Loop-Operation
179
U/F-Characteristic Curve
179
Slip-Compensation
180
Improvements with Open-Loop-Operation
181
Optimizing Start up Behavior
181
Slip-Compensation
181
Tilting Protection
181
Operation with a 3-Phase 230 VAC Power Supply
182
Controlled Emergency Stop in Inclined Elevators
183
Travel Direction Counter
184
Parameters for the Travel Direction Counter
184
Parametrization of the Counter
184
Output Functions
185
Resetting the Travel Direction Counter
185
Self-Monitoring of the Brakes According to EN81-A3
185
Activation of the Self-Monitoring
185
Activation of the ZETADYN Lock in Case of a Malfunctioning Brake Circuit
186
Function Test of the Self-Monitoring
186
16 Enclosure
187
Technical Data ZETADYN 3C
187
Zetadyn 3C011
187
Zetadyn 3C040
187
EU Declaration of Conformity
189
Adjustment Card
191
Brake Resistor Allocation
192
Type Designation
193
Part no
194
Certificates
195
Index
201
Advertisement
ZIEHL-ABEGG ZETADYN 3BF Brief Instructions (10 pages)
ZETADYN 3 Series Additional information for CANopen Lift
Brand:
ZIEHL-ABEGG
| Category:
DC Drives
| Size: 1.27 MB
Table of Contents
Table of Contents
2
1 General Notes
3
Validity
3
Structure of the Operating Instructions
3
Exclusion of Liability
3
2 Safety Information
3
3 Start-Up
4
Information for Start-Up
4
Frequency Inverter
4
Bus-Cable
4
Wiring
4
Electrical Connection
5
Activating the Interface
5
Operation Mode
6
Command- and Statusbits of the Recorder
7
4 Parameter
7
Parameter Settings
7
Info Menu
8
Network Management Status
9
5 Error
9
Error Diagnosis in Canopen Lift
9
Error List
9
ZIEHL-ABEGG ZETADYN 3BF Technical Information (26 pages)
Brand:
ZIEHL-ABEGG
| Category:
Inverter
| Size: 4.82 MB
Advertisement
Advertisement
Related Products
ZIEHL-ABEGG ZETADYN 3BF009-1
ZIEHL-ABEGG 308140
ZIEHL-ABEGG 308007
ZIEHL-ABEGG 308251
ZIEHL-ABEGG 308320
ZIEHL-ABEGG 308302
ZIEHL-ABEGG ZETADYN 3-ZAdyn4C
ZIEHL-ABEGG 308008-UL
ZIEHL-ABEGG 308182
ZIEHL-ABEGG 308177
ZIEHL-ABEGG Categories
Fan
Engine
Control Unit
DC Drives
Controller
More ZIEHL-ABEGG Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL