Liebert NXL
Vertiv Liebert NXL UPS System Manuals
Manuals and User Guides for Vertiv Liebert NXL UPS System. We have
5
Vertiv Liebert NXL UPS System manuals available for free PDF download: Installation Manual, Product Specification/Installation Sheet
Vertiv Liebert NXL Installation Manual (102 pages)
625-1100kVA, 1.0PF, 60Hz, Three-Phase, SingleModule & Multi-Module
Brand:
Vertiv
| Category:
UPS
| Size: 20 MB
Table of Contents
Table of Contents
3
Important Safety Instructions
9
1 Mechanical Installation
11
Introduction
11
Preliminary Checks
11
Environmental Considerations
11
UPS Room
11
Storing the UPS and Batteries for Delayed Installation
12
Positioning
12
Moving the Cabinets
12
Clearances
13
Raised-Floor Installations
13
Kick Plate Installation
13
Special Considerations for 1+N Parallel Systems
13
System Composition
14
Cable Entry
15
Figure 1 Cabinet Arrangement-Liebert NXL, Battery Cabinets, Maintenance Bypass Cabinet
15
2 Ups Electrical Installation
16
External Protective Devices
16
Power Cables
16
Sizing the Input Breaker Feeding a Liebert NXL UPS
18
Power Cable Connection Procedure
18
Figure 2 Cabinet Grounding Plates
19
Figure 3 Kick Plate and Filter Locations
19
Figure 4 Low-Voltage Cable Installation-Top Entry
20
Control Cable and Communication
21
Dry Contacts
21
Figure 5 External Interface Board Connections Layout
21
Table 1 UPS Input Dry Contacts
21
Multi-Module Communication
23
Table 5 Parallel from UPS Module Inter-Module Communication Board to Other Inter-Module
23
Remote Input Breaker (RIB)
24
Figure 6 Inter-Module Communication Board Wiring Diagram-Multi-Modules
24
Figure 7 Remote Input Breaker Diagram
25
Inverter Output Breaker
26
Table 6 RIB UV Coil, Aux. Contacts from UPS RIB CB Interface Board to Remote CB1
26
Figure 8 Remote Output Breaker Diagram
27
Table 7 Remote IOB Contacts from Remote Breaker to UPS IOB CB Interface Board
27
Digital LBS
28
Table 8 Wire Size, Length for Digital LBS Connection of UPS Inter-Module Communication
28
Configuring Neutral and Ground Connections
29
Four-Wire Input Connections
29
Figure 10 Grounding Diagram-Four-Wire Single-Module Systems
29
Three-Wire Input Connections
30
Figure 11 Grounding Diagram-Four-Wire Multi-Module Systems
30
Figure 12 Grounding Diagram-Three-Wire Single-Module Systems
31
Figure 13 Grounding Diagram-Three-Wire Multi-Module Systems
31
Preferred Grounding Configuration, Battery Systems
32
Multi-Module Systems
32
High-Resistance Ground Systems
32
3 Optional Equipment
33
Single-Module System Options
33
Battery Temperature Sensor
33
Matching Liebert NXL Battery Cabinet
33
Load Bus Synch
33
Remote Alarm Status Panel
33
Communication and Monitoring
33
Alber Monitoring System
33
4 Installation Drawings
34
Figure 14 Main Components, 625Kva Liebert NXL, N+1 Multi-Module Unit Without Static Bypass
34
Figure 15 Main Components, 625Kva Liebert NXL UPS, SMS and 1+N Multi-Module Unit with
35
Figure 16 Outline Drawing, 625Kva Liebert NXL, N+1 Multi-Module Unit Without Static Bypass
36
Figure 17 Outline Drawing, 625Kva Liebert NXL, SMS and 1+N Multi-Module Unit with Static by
37
Figure 18 Base Detail Drawing, 625Kva Liebert NXL, N+1 Multi-Module Unit Without Static by
38
Figure 19 Base Drawing, 625Kva Liebert NXL, SMS and 1+N Multi-Module Unit with Static by
39
Figure 20 Input Terminal Detail, 625Kva Liebert NXL, N+1 Multi-Module Unit Without Static by
40
Figure 21 Input Terminal Detail, 625Kva Liebert NXL, SMS and 1+N Multi-Module Unit with Static
41
Figure 22 Output Terminal Detail, 625Kva Liebert NXL, N+1 Multi-Module Unit Without Static Bypass
42
Figure 23 Output Terminal Detail, 625Kva Liebert NXL, SMS and 1+N Multi-Module Unit with
43
Figure 24 Shipping Split 625Kva Liebert NXL Without Static Bypass
44
Figure 25 Shipping Split 625Kva Liebert NXL Without Static Bypass (Continued)
46
Figure 26 Shipping Split, 625Kva Liebert NXL, SMS and 1+N Multi-Module Unit with Static by
48
Figure 27 Shipping Split, 625Kva Liebert NXL, SMS and 1+N Multi-Module Unit with Static Bypass
50
Figure 30 Outline Drawing Liebert NXL 800Kva UPS 1+N Multi-Module or SMS with Static by
52
Figure 31 Outline Drawing Liebert NXL 800Kva UPS 1+N Multi-Module or SMS with Static Bypass
53
Figure 32 Outline Drawing Liebert NXL 800Kva UPS N+1 Multi-Module Without Static Bypass
54
Figure 33 Outline Drawing Liebert NXL 800Kva UPS N+1 Multi-Module Without Static Bypass
55
Figure 34 Input Terminal Details Liebert NXL 800 Kva UPS, 1+N Multi-Module or SMS with Static
56
Bypass
57
Figure 35 Input Terminal Details Liebert NXL 800 Kva UPS, 1+N Multi-Module or SMS with Static
57
Figure 36 Power Wiring-Liebert NXL 800Kva, Single Module System or 1+N, Shipping Split
58
Figure 37 Interconnections between Inverter and Bypass-Liebert NXL 800Kva, Single Module
59
Bypass (Continued)
60
Figure 38 Control Wiring-Liebert NXL 800Kva, Single Module or 1+N System, Shipping Split
60
Table 9 Interconnects for 800Kva UPS Single or 1+N Module Unit
61
Figure 39 Power Wiring-Liebert NXL 800Kva, N+1 System, Shipping Split
62
Figure 40 Interconnections between Inverter and Bypass-Liebert NXL 800Kva, N+1, Shipping
63
Figure 41 Control Wiring-Liebert NXL N+1 800Kva, N+1 System, Shipping Split
64
Table 10 Interconnects for 800KVA UPS Multi-Module Unit
64
Figure 42 Liebert NXL 1100Kva Conduit Entry Points-Input Layout
66
Figure 43 Liebert NXL 1100Kva Conduit Entry Points-DC Layout
66
Figure 44 Liebert NXL 1100Kva Conduit Entry Points-N+1 Output Layout
67
Figure 45 Liebert NXL 1100Kva Conduit Entry Points-SMS/1+N Output Layout
68
Figure 46 Main Components, 1+N Multi-Module or SMS with Static Bypass, 1100Kva UPS
69
Figure 47 Conduit Landing, 1100Kva UPS 1+N Multi-Module or SMS with Static Bypass
70
Figure 48 Main Components, 1100Kva UPS N+1 Multi-Module Without Static Bypass
71
Figure 49 Outline Drawing 1100Kva UPS N+1 Multi-Module Without Static Bypass
72
Figure 50 Liebert 1100Kva, Multi-Module System, Shipping Split-Power Wiring
73
Figure 51 Liebert NXL 1100Kva, Multi-Module System, Shipping Split-Interconnections Be- Tween
74
Figure 52 Liebert NXL 1100Kva, Multi-Module System, Shipping Split-Control Wiring
75
Table 11 Interconnects for 1100Kva UPS Multi-Module Unit
76
Figure 53 Liebert NXL 1100Kva, Single Module System, Shipping Split-Power Wiring
78
Figure 54 Liebert NXL 1100Kva, Single Module System, Shipping Split-Interconnections Be- Tween
79
Figure 55 Control Wiring-Liebert NXL 1100Kva, Single Module System, Shipping Split
80
Table 12 Interconnects for 1100KVA UPS Single Module Unit
81
Figure 56 Conduit Landing Drawing 1100Kva UPS N+1 Multi-Module Without Static Bypass
82
Figure 57 Terminal Details 1100Kva UPS, N+1 Multi-Module Without Static Bypass
83
Figure 58 Busbar Terminal Details, 1100Kva UPS, N+1 Multi-Module Without Static Bypass
83
Figure 59 Terminal Details, 1100Kva UPS, 1+N Multi-Module or SMS with Static Bypass
84
Figure 60 Busbar Terminal Details, 1100Kva UPS, 1+N Multi-Module or SMS with Static Bypass
85
Figure 61 Base Detail Drawing 1100Kva UPS 1+ N Multi-Module or SMS with Static Bypass
86
Figure 62 Base Detail Drawing 1100Kva UPS N+1 Multi-Module Without Static Bypass
87
Figure 63 Auxiliary Wiring Cabinet- 625Kva Only
88
Figure 64 Optional Input Contact Isolator Board
89
Table 13 Input Contact Isolator Board Control Wiring Connections
89
Figure 65 Control Wiring, Programmable Relay Board
90
Table 14 Programmable Relay Board Pin out
90
Table 15 Liebert NXL UPS Specifications
91
Table 16 Current Ratings-Rectifier Input
93
Table 17 Current Ratings-Bypass Input
93
Table 18 Current Ratings-Output
93
Table 19 Current Ratings-Battery
93
Figure 66 Inverter Overload Data
94
Figure 67 Rectifier Overload Data
95
Figure 68 Bypass Overload Data
96
Table 20 Recommended Conduit and Cable Sizes
97
Table 21 Recommended Lug Sizes
98
Table 22 Recommended Torque Values
98
Advertisement
Vertiv Liebert NXL Installation Manual (87 pages)
Large System, 3-Phase UPS Battery System
Brand:
Vertiv
| Category:
UPS
| Size: 12 MB
Table of Contents
Table of Contents
4
Important Safety Instructions
10
1 Mechanical Installation
13
Introduction
13
Preliminary Checks
13
Environmental Considerations
13
Battery Room
13
1.3.2 Storage for Delayed Installation
13
Positioning
15
Moving the Cabinets
15
Figure 1 Shipping Bolts-Top-Terminal Battery Cabinet, Standard Width
16
Figure 2 Shipping Bolts-Top-Terminal Battery Cabinet, Reduced Width
16
1.4.2 Clearances
17
1.4.3 Raised Floor Mounting
17
System Composition
17
2 Battery Installation
18
Safety
18
Layout
19
Figure 3 Top-Terminal Battery System Configurations-Liebert® EXL
19
Figure 4 Top-Terminal Battery System Configurations Attached to UPS-Liebert® EXL™ S1
20
Figure 5 Top-Terminal Battery System Configurations-Liebert® NX™ 225-600Kva
21
Figure 6 Top-Terminal Battery System Configurations-Liebert® NXL
22
Figure 7 Top-Terminal Stand-Alone Battery System Configuration-Liebert® EXL™, Liebert® EXL™ S1
23
Figure 8 Top-Terminal Battery System Configuration-Battery Cabinets Not Attached to UPS or each
23
Figure 9 Front-Terminal Battery System Configurations-Liebert® EXL
24
Figure 10 Front-Terminal Battery System Configurations Attached to UPS-Liebert® EXL™ S1
25
Figure 11 Front-Terminal Battery System Configurations-Liebert® NX
26
Figure 12 Front-Terminal Battery System Configurations-Liebert® NXL
27
Control Cable Entry
28
DC Power Connections
28
2.4.1 Connected Battery Systems
28
2.4.2 Connected or Stand-Alone Arrangement
28
Figure 13 Front-Terminal Stand-Alone Battery System Configuration-Liebert® EXL™, Liebert® EXL™ S1
28
Figure 14 Front-Terminal Battery System Configuration-Battery Cabinets Not Attached to UPS or each
28
2.4.3 DC Power Connections-Liebert® EXL™ S1
29
2.4.4 Grounding
30
Control Connections
30
Figure 15 Control Cable Layout-Liebert® UPS to Liebert® Battery Cabinet
30
2.5.1 Liebert® EXL™ and Liebert® EXL™ S1-UPS Control Contacts with Battery Cabinet
31
Figure 16 TB1154 Location-Liebert® EXL
31
Table 1 Liebert® EXL™ and Liebert® EXL™ S1 UPS Control Contacts to Battery Interface Boards
31
2.5.2 Liebert® NX™-UPS Control Contacts with Battery Cabinet
32
Figure 17 TB1154 Location, BIB Connection-Liebert® EXL™ S1
32
Figure 18 TB3 Location-225-300Kva Liebert® NX™, SMS and 1+N Multi-Module Unit with Static
33
Table 2 Liebert® NX™UPS Control Contacts to Battery Interface Boards
33
Figure 19 TB3 Location-Liebert® NX™ 400-600Kva, SMS and 1+N Multi-Module Unit with Stat- IC
34
2.5.3 Liebert® NXL™-UPS Control Contacts with Battery Cabinet
35
Figure 20 Wiring External Interface Board in Liebert® NXL™ to Battery Interface Board in Battery
35
Alber® Monitoring System-Optional
36
External Battery Room Temperature Sensor-Optional
36
Figure 21 Battery Temperature Sensor Control Connection
37
Figure 22 Outline and Terminal Details, Optional Auxiliary Temperature Sensor for Liebert® EXL
38
3 Installation Drawings
39
Installation Drawings-Top Terminal Battery Cabinets
39
Figure 23 Top-Terminal Battery Cabinet Layout
39
Figure 24 Ground Strap Location for Connected Top-Terminal Battery Cabinets
40
Figure 25 Outline Drawing, Liebert® Top-Terminal, 47" (1194Mm) Wide Battery Cabinet (1194Mm)
41
Figure 27 Outline Drawing, Liebert® Top-Terminal, 55" (1400Mm) Wide Battery Cabinet for Lieb- Ert
43
Figure 28 Main Components, Top-Terminal, 55" (1400Mm) Wide Battery Cabinet for Liebert
44
Figure 29 Terminal Details, Top-Terminal, 55" (1400Mm) Wide Battery Cabinet for Liebert® EXL™, Liebert® EXL™ S1, Liebert® NX™ 225-600Kva and Liebert® NXL
45
Battery
46
Figure 31 Liebert® EXL™ S1 625-800Kva UPS Input/Output Cabinet 1 to Top-Terminal Battery
47
Figure 32 Liebert® EXL™ S1 1000-1200Kva UPS Input/Output Cabinet 1 to Top-Terminal Battery
48
Figure 33 Liebert® EXL™ S1 625-800Kva UPS Input/Output Cabinet 2 or 3 to Top-Terminal Bat
49
Figure 34 Liebert® EXL™ S1 1000-1200Kva UPS Input/Output Cabinet 2 or 3 to Top-Terminal
50
Figure 35 Busbar Shroud for Input/Output Cabinet 2 or 3, Top-Terminal or Front-Terminal Battery
51
Ebert
51
Installation Drawings-Front Terminal Battery Cabinets
52
Figure 36 Front-Terminal Battery Cabinet Layout
52
Figure 37 Front-Terminal Battery Cabinet Shipping Split
53
Figure 38 Outline Drawing Liebert® 63" (1600Mm) Wide, Front-Terminal Battery Cabinet for Lieb- Ert® EXL™, Liebert® EXL™ S1, Liebert® NX™ 225-600Kva and Liebert® NXL
54
Figure 39 Main Components, Liebert® 63" (1600Mm) Wide Front-Terminal Battery Cabinet for Li- Ebert
55
Figure 40 Terminal Details, Cable Entry Liebert® 63" (1600Mm) Wide Front-Terminal Battery Cab
56
Installation Drawings-Junction Cabinets
57
Figure 41 Busbar Connection between Battery Cabinet and Attached Junction Cabinet
57
Figure 42 Terminal Details-Liebert® Stand-Alone 17" 800-1200Kva Junction Cabinet
58
Figure 43 17" Junction Cabinet Junction Cabinet-Cable Entry
59
Figure 44 Terminal Details-Liebert® Stand-Alone 32" (813Mm) Junction Cabinet
60
Figure 45 Terminal Details-Liebert® 15-1/2" Attached Junction Cabinet, 500-750 Kva
61
Figure 46 Outline Drawing-Liebert® 15-1/2" Attached Junction Cabinet
62
Figure 47 17" Junction Cabinet Junction Cabinet
63
Figure 48 Liebert® Battery Cabinet Control Wiring
64
Figure 49 Attached Battery Cabinet Connections
65
Figure 50 Liebert® Top-Terminal, 55" (1400Mm) Battery Cabinet Interconnect Wiring to Liebert
66
Figure 51 Liebert® EXL™ S1 625-800Kva UPS Input/Output Cabinet 1 to Front-Terminal Battery
67
Figure 55 Terminal Details, 625/750 Liebert® NXL 1+N Multi-Module or SMS with Static Bypass
71
Figure 56 Terminal Details, Liebert® NXL™ 800Kva 1+N Multi-Module or SMS with Static Bypass
72
Installation Drawings-Alber® Battery Monitoring
73
Figure 57 Typical Alber Battery Monitoring Connections
73
Battery Monitoring Option
74
Cabinet
74
Figure 58 Alber Battery Monitoring Wiring to Multiple Battery Cabinets
74
Battery Monitoring Assembly Diagram
75
Cabinet
75
Figure 59 Alber
75
Table 3 Alber Battery Monitoring Assembly Connections
76
4 Specifications
77
Table 4 Liebert® NXL™ Battery Cabinet Specifications
77
Cabinet
77
Table 5 Liebert® NXL™ Junction Cabinet Specifications
78
Table 6 Electrical Values for Alber
78
Cabinet
78
Cabinet
79
Table 7 Battery Cabinet Weights and Breaker Frame Size
79
Cabinet
80
Recommended Lug Sizes
81
Vertiv Liebert NXL Installation Manual (58 pages)
250-400kVA, 60Hz, Three-Phase, Single-Module and Multi-Module Units
Brand:
Vertiv
| Category:
UPS
| Size: 5 MB
Table of Contents
Table of Contents
3
Important Safety Instructions
7
1 Single-Module and Multi-Module Mechanical Installation
9
Introduction
9
Preliminary Checks
9
Environmental Considerations
10
UPS Room
10
Storing the UPS and Batteries for Delayed Installation
10
Positioning
10
Moving the Cabinets
11
Clearances
11
Raised Floor Installations
11
Kick Plate Installation
11
Special Considerations for 1+N Parallel Systems
12
System Composition
12
Cable Entry
12
Cabinet
13
Figure 1 Cabinet Arrangement-Liebert NXL Single-Module, Battery Cabinets, Maintenance Bypass
13
Figure 2 Cabinet Arrangement-Liebert NXL 400Kva, 575-600V Multi-Module and Battery
13
2 Ups Electrical Installation
14
External Protective Devices
14
Power Cables
14
Sizing the Input Breaker Feeding a Liebert NXL UPS
15
Power Cable Connection Procedure
15
Figure 3 Cabinet Grounding Plates
17
Figure 4 Kick Plate and Filter Locations, Typical
17
Control Cable and Communication
18
Figure 5 External Interface Board Connections Layout
18
Dry Contacts
19
Table 1 UPS Input Dry Contacts
19
Table 2 UPS Control with Battery Cabinet or Module Battery Disconnect
19
Table 3 UPS Control Contacts with Global Maintenance Bypass
19
Multi-Module Communication
20
Communication Board in System
20
Table 4 UPS Control Contacts to Remote Status Panel
20
Table 5 Parallel from UPS Module Inter-Module Communication Board to Other Inter-Module
20
Digital LBS
21
Figure 6 Inter-Module Communication Board Wiring Diagram-Multi-Modules
21
Figure 7 Inter-Module Communication Board Wiring Diagram-Digital LBS
21
Table 6 Wire Size, Length for Digital LBS Connection of UPS Inter-Module Communication
21
Configuring Neutral and Ground Connections
22
Four-Wire Input Connections
22
Three-Wire Input Connections
22
Preferred Grounding Configuration, Battery Systems
22
Multi-Module Systems
23
High Resistance Ground Systems
23
Grounding Diagrams, Single- and Multi-Module Systems
23
Figure 8 Grounding Diagram, Three-Wire Single-Module System
23
Figure 9 Grounding Diagram, Four-Wire Single-Module System
23
Figure 10 Grounding Diagram, Three-Wire Multi-Module System
24
Figure 11 Grounding Diagram, Four-Wire Multi-Module System
25
3 Optional Equipment
26
Single-Module System Options
26
Matching Maintenance Bypass Cabinet
26
Battery Temperature Sensor
26
Load Bus Synch
26
Remote Alarm Panel
26
Communication and Monitoring
26
Alber Monitoring System
26
Programmable Relay Board
26
Figure 12 Control Wiring, Programmable Relay Board
27
Input Contact Isolator Board
28
Figure 13 Programmable Relay Board Dialog Box
28
Figure 14 Input Contact Isolator Dialog Box
29
Figure 15 Optional Input Contact Isolator Board
30
Table 8 Input Contact Isolator Board Pre-Assigned Values
30
Table 9 Input Contact Isolator Board Control Wiring Connections
30
4 Installation Drawings
31
Figure 16 Outline Drawing, 250Kva, 480V Liebert NXL
31
Figure 17 Outline Drawing, 250Kva, 575/600V; and 300Kva, 480/575/600V Liebert NXL
32
Figure 18 Outline Drawing, 400Kva, 480V Liebert NXL
33
Figure 19 Outline Drawing, 400Kva, 575V/600V Liebert NXL
34
Figure 20 Outline Drawing, 400Kva, 575V/600V Liebert NXL with DC I/O Cabinet
35
Figure 21 Main Components, 250Kva, 480V Liebert NXL
36
Figure 22 Main Components, 250Kva, 575/600V, and 300Kva, 480/575/600V Liebert NXL
37
Figure 23 Main Components, 400Kva, 480V Liebert NXL
38
Figure 24 Main Components, 400Kva, 575V/600V Liebert NXL
39
Figure 25 Main Components, 400Kva, 575V/600V Liebert NXL with DC I/O Cabinet
40
Figure 26 Input/Output Conduit Detail Drawing, 250-300Kva, All Voltages, Liebert NXL
41
Figure 27 Input/Output Terminal Detail, 400Kva, 480V Liebert NXL
42
Figure 28 Input/Output Terminal Detail, 400Kva, 575V/600V Liebert NXL
43
Figure 29 Input/Output Terminal Detail, 400Kva, 575V/600V Liebert NXL with DC I/O Cabinet
44
Figure 30 Top Cable Entry Routing and Installation Order
45
Figure 31 Bottom Cable Entry Routing and Installation Order
46
Figure 32 Single-Input Busbar Arrangement-250-400Kva Units
47
Figure 33 Low-Voltage Cable Entry-250-400Kva Units
47
5 Specifications
48
Table 10 Liebert NXL UPS Specifications
48
Table 11 Current Ratings-Rectifier Input
50
Table 12 Current Ratings-Bypass Input
50
Table 13 Current Ratings-Output
50
Table 14 Current Ratings-Battery
51
Table 15 Recommended Conduit and Cable Sizes
51
Figure 34 Inverter Overload Data
53
Figure 35 Bypass Overload Data
54
Table 16 Recommended Lug Sizes
55
Table 17 Recommended Torque Values
55
Advertisement
Vertiv Liebert NXL Installation Manual (24 pages)
Power-Tie Controls
Brand:
Vertiv
| Category:
Control Unit
| Size: 1 MB
Table of Contents
Contacting Vertiv for Support
2
Table of Contents
3
Important Safety Instructions
5
1 0 Mechanical Installation
6
Introduction
6
Preliminary Checks
6
2 0 Control Connections and Communication
7
Control Cable and Communication
7
Breaker Interface Board
7
Figure 1 External Interface Board Connections Layout
7
Figure 3 Voltage and Current Sensing Terminal
8
Figure
9
Programmable Relay Board
9
Control Wiring, Programmable Relay Board
9
Table 1 Programmable Relay Board Pinout
9
Table 1
9
Programmable Relay Board Dialog Box
10
Inter-Module Control Wiring
11
(Optional)
11
Table 2 Cable Group #22A - from SIB Breaker Interface Board (BIB) to SIB Breaker
11
Table 4 Cable Group #23A - from Tie Breaker Interface Board (BIB) to Tie Breaker
11
Table 6 Cable Group #24A - from MBB Breaker Interface Board (BIB) to MBB Breaker
11
(Optional)
12
Liebert NXL Power-Tie Inter-Module Communication Board
12
Table 10 Cable Group #26A - from LBB Breaker Interface Board (BIB) to LBB Breaker
12
Table 8 Cable Group #25A - from MIB Breaker Interface Board (BIB) to MIB Breaker
12
Table 12 Cable Group #27B - Redundant Parallel from SCC/UPS Inter-Module Communication
13
Table 13 Cable Group #28A - Parallel from Liebert NXL Power-Tie Inter-Module Communication Board to Next Liebert NXL Power-Tie Inter-Module Communication Board
13
Table 14 Cable Group #28B - Redundant Parallel Liebert NXL Power-Tie Inter-Module Communication Board to Next Liebert NXL Power-Tie Inter-Module Communication
13
Table 15 Cable Group #29A - from MBB Breaker Interface Board to SKRU Interface
13
Table 16 Cable Group #29B - from MBB Breaker Interface Board to SKRU Interface
13
Table 17 Cable Group #32 - from Liebert NXL Power-Tie Control Terminal Block to Voltage and
14
3 0 Installation Drawings
15
Figure 6 Control Wiring Layout for Liebert NXL Power-Tie
15
Figure 7 Liebert NXL Power-Tie System #1 Layout
16
Vertiv | Liebert
16
Board
16
Liebert NXL Power-Tie System #2 or #3 Layout
17
Figure 9 Liebert NXL Power-Tie Control Wiring for Single System
18
4 Specifications
19
VERTIV Liebert NXL Product Specification/Installation Sheet (4 pages)
Battery Interface Box installation
Brand:
VERTIV
| Category:
UPS
| Size: 0 MB
Table of Contents
Save These Instructions
1
Placement and Cable Entry
1
Control Connection
1
Dimensions and Layout
2
Control Wiring Routing
2
External Battery Room Temperature Sensor—Optional
3
DC Sense Connections—Optional
3
DC Breaker Undervoltage Release (Uvr) Contacts
3
Can Communication Connections
3
Motor Operator Connections
3
Table 1 Cable Groups
4
Table 2 Battery Interface Box Specifications
4
Advertisement
Related Products
Vertiv Liebert iCOM
Vertiv Liebert MBSM
Vertiv Liebert CW
Vertiv Liebert NX
Vertiv Liebert NXL SCCi
Vertiv Liebert NXL Series
Vertiv Liebert APS series
Vertiv Liebert LDMF
Vertiv Liebert SRC-G Series
Vertiv Liebert AHU Series
Vertiv Categories
UPS
Power Supply
Switch
Power distribution unit
Air Conditioner
More Vertiv Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL