Sign In
Upload
Manuals
Brands
Vertiv Manuals
Power Supply
581126000
Vertiv 581126000 DC Power System Manuals
Manuals and User Guides for Vertiv 581126000 DC Power System. We have
1
Vertiv 581126000 DC Power System manual available for free PDF download: User Manual
Vertiv 581126000 User Manual (208 pages)
Brand:
Vertiv
| Category:
Power Supply
| Size: 4 MB
Table of Contents
Table of Contents
3
Admonishments Used in this Document
8
Important Safety Instructions
9
Safety Admonishments Definitions
9
General Safety
9
Voltages
9
AC Input Voltages
9
DC Output and Battery Voltages
9
Battery
10
Personal Protective Equipment (PPE)
11
Hazardous Voltage
11
Handling Equipment Containing Static Sensitive Components
11
Maintenance and Replacement Procedures
11
Static Warning
12
FCC Information
13
System Overview
15
Preface
15
System Description
15
Navigating the MCA
17
MCA Messages
20
System Operating Procedures
41
Rectifier Operating Procedures
41
Converter Operating Procedures
41
Winlink Software User Instructions
41
MCA Ethernet Card WEB Interface User Instructions
41
Battery Temperature Probe Concentrator Module (TXM)
41
Local Controls and Indicators
41
Location and Identification
41
MCA Display
43
MCA Front Panel Accessed Interface Pad
43
Low Voltage Disconnect NOR/INH Switch and INH Indicator (if Low Voltage Disconnect Load Contactor Is Furnished)
46
Manual Battery Disconnect Switch and Indicator (List RB, RC, RD Only)
47
External Alarms
48
Starting and Stopping System Operation
50
Rectifier Module Normal Starting Procedure
50
Rectifier Module Stopping Procedure (Local)
50
DC-DC Converter Module Normal Starting Procedure
51
DC-DC Converter Module Stopping Procedure (Local)
51
Initially Connecting Battery and System Output to the Controlled
51
Output Voltage Mode of Operation Selection
52
Placing the System into the Float Mode of Operation
52
Placing the System into the Test/Equalize Mode of Operation
52
Restarting Procedures When Rectifier Module (PCU) Is Automatically or Manually Inhibited, Shut Down, or Locked out
58
Rectifier Module High Voltage Shutdown and Lockout
58
Rectifier Module Emergency Shutdown and Fire Alarm Disconnect
58
Remote On/Off (TR)
58
Restarting a DC-DC Converter Following a High Voltage Shutdown
58
Low Voltage Disconnect Reconnect Procedure (WHEN FURNISHED and SET for MANUAL RECONNECT)
58
Reconnect
59
Battery Recharge Current Limit Feature
60
Description
60
Enabling and Disabling the Feature
61
Battery Charge Current Alarm Feature
61
Measuring Battery Charge/Discharge Current
61
Using the Alarm Relay Test Feature
61
Setting the Alarm Relay Test Feature Time Period
61
Performing an Alarm Relay Test
62
Setting MCA Audible Alarm Cutoff Reset Time Period
64
Setting Rectifier Module (PCU) / Converter Module Fan Speed Control (Normal and Variable Speed) Feature
65
Description
65
Enabling or Disabling the Rectifier Module / Converter Module Variable-Speed Fan Control Feature
65
Setting the Alternating Display Feature
66
Enabling or Disabling the Alternating Display Feature
66
Setting the MCA Load Share Alarm Feature
66
Enabling or Disabling the 'Load Share Alarm' Feature
67
Setting the MCA Emergency Stop Feature
67
Enabling or Disabling the 'MCA Emergency Stop' Feature
67
Setting the MCA Remote High Voltage Shutdown Feature
68
Enabling or Disabling the ' Remote High Voltage Shutdown ' Feature
68
Accessing the MCA Via the Interface Option
69
Accessing the MCA Remotely Via Winlink Software
69
Accessing the MCA Remotely Via a Web-Browser
69
Option Furnished)
69
Accessing the MCA Remotely Via SNMP (if Ethernet Interface Option with SNMP Interface Furnished)
69
To Display Remote Access Password
70
To Move Back to the Beginning of the MCA Logic Tree
70
To View Active Alarms
70
To View Measurement Parameters
71
Viewing System Current Capacity
71
Viewing Inventory Items
72
MCA "Power Down" Mode
72
MCA System Adjustments
73
Adjustment Location and Identification
73
Adjusting Float Output Voltage
74
Adjusting Test/Equalize Output Voltage
76
Adjusting High Voltage Shutdown
78
Adjusting System Current Limit
80
Adjusting System High Voltage Alarm 1
81
Adjusting System High Voltage Alarm 2
82
Adjusting System Battery on Discharge Alarm
83
Adjusting System 50% Battery on Discharge (very Low Voltage)
84
Alarm
84
Adjusting System Current Alarm
85
Adjusting Subsystem (if Connected) High Voltage Alarm
86
Adjusting Subsystem (if Connected) Low Voltage Alarm
87
Adjusting Subsystem (if Connected) Current Alarm
88
Adjusting Low Voltage Disconnect (if Installed) "Disconnect" Value
89
Circuits Installed
91
Calibrating System Output Voltage Reading
92
Calibrating Subsystem (if Connected) Output Voltage Reading
93
Returning System and Subsystem Output Voltage Reading Calibrations to Their Default Values
94
Slope
95
Maximum Voltage
96
Minimum Voltage
97
Calibrating Battery Charge Temperature Compensation Source
98
Adjusting Battery Ambient High Temperature Alarm (if Battery Charge Digital Temperature Compensation Probe Is Installed)
99
Adjusting Battery Ambient Low Temperature Alarm (if Battery Charge Digital Temperature Compensation Probe Is Installed)
100
Limit Setting
101
Setting the "Battery Charge Current Alarm" Value
102
Manually Initiated Timed Test/Equalize Feature
103
Automatic Test/Equalize Feature
103
Alarm Relay Test Feature
103
MCA Audible Alarm Cutoff Reset Time Period
103
Rectifier Module / Converter Module Fan Speed Control Feature
103
Alternating Display Feature
103
MCA Load Share Alarm Feature
103
MCA Emergency Stop Feature
103
MCA Remote High Voltage Shutdown Feature
103
System Maintenance
104
Admonishments
104
General Safety
104
Voltages
104
System Maintenance Procedures
105
Adding a Rectifier or DC-DC Converter Module to an Existing Shelf
118
Adding a Module Mounting Shelf to the Power System
120
Installing LVD Contactor Bypass Kits P/NS 514910 and 514912
125
Installing Kit Part No. 514910
125
Installing Kit Part No. 514912
127
System Troubleshooting and Repair
129
Contact Information
129
Admonishments
129
General Safety
129
Voltages
129
Circuit Cards
130
Rectifier Module Troubleshooting Procedures
130
Converter Module Troubleshooting Procedures
130
Troubleshooting Information
131
General
131
Adjustments
131
MCA Messages
131
Additional MCA Messages
132
Bypass Circuit Card Requirement
132
Updating the Inventory after Changes to the System Have Been Made
133
Replacement Information
134
Replacement Assemblies
134
Replacement Cables
134
Replacement Procedures
134
Replacing a Rectifier Module (PCU)
134
Replacing a Converter Module
134
MCA Replacement
134
Rectifier Shelf Interface Circuit Card Replacement
156
Quad Low Voltage Disconnect Circuit Card Replacement
160
Quad Shunt POD Circuit Card Replacement
163
Alarm Termination/Audible Alarm Circuit Card Replacement
166
Interconnect/Lvd Inhibit Circuit Card Replacement
169
List RD and RE Shunt POD Circuit Card Replacement
173
Alarm, Reference, and Control Fuse Replacement
175
Replacing a TPS/TLS-Type Fuse
178
Replacing a Bullet Nose Type Fuseholder
180
Replacing a TPH-Type Fuse
181
Replacing a Bullet Nose Type Circuit Breaker
183
And RE
185
Replacing a List RA, RB Battery Disconnect Contactor
200
Replacing a List RC, RD, RE Battery Disconnect Contactor
203
Adding a Battery Charge Digital Temperature Compensation Probe to a Previously Operated System
206
Removing a Battery Charge Digital Temperature Compensation Probe from a Previously Operated System
207
Advertisement
Advertisement
Related Products
Vertiv 581127000
Vertiv 588250400
Vertiv 588250300
Vertiv 582127000600-901
Vertiv 582127000901
Vertiv NetSure 588820200SK002
Vertiv NetSure 588820200SK003
Vertiv NetSure 588820200SK004
Vertiv NetSure 582136700SK001
Vertiv NetSure 582136700SK008
Vertiv Categories
UPS
Power Supply
Switch
Power distribution unit
Air Conditioner
More Vertiv Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL