Sign In
Upload
Manuals
Brands
Thermo Scientific Manuals
Laboratory Equipment
Matrix 1029
Thermo Scientific Matrix 1029 Manuals
Manuals and User Guides for Thermo Scientific Matrix 1029. We have
2
Thermo Scientific Matrix 1029 manuals available for free PDF download: User Manual, Operating And Maintenance Manual
Thermo Scientific Matrix 1029 Operating And Maintenance Manual (59 pages)
Forma Anaerobic System
Brand:
Thermo Scientific
| Category:
Laboratory Equipment
| Size: 0 MB
Table of Contents
Table of Contents
7
Installation and Start-Up
10
Location
11
Connect the Vacuum Source
12
Connect the Gas Supplies
13
Gas Recommendations
13
To Connect the Gas Supplies
13
Connection for Start-Up
14
Connection for Normal Operation
14
Connect the Foot Switch (Optional)
14
Installing the Gloves
14
Connect to Power
14
Install Equipment
15
Charcoal, Catalyst & Desiccant Wafers
15
Prepare the Chamber Relief Bubbler
16
Inspection before Start-Up
16
Start-Up Procedure
17
Automatic Operation of the Interchange
18
Manual Operation of the Interchange
20
Initial Settings
21
Set Incubator Temperature
21
Set Overtemp Safety Thermostat
21
Operation
22
Interchange Vacuum Gauge
23
Manual Chamber Fill Knob
23
Glove Chamber Relief Bubbler
23
Interchange Status Indicator Lights
23
Inner and Outer Door Indicator Lights
23
Start Cycle Button
24
Transfer Function Switches
24
Interchange Cycle Indicator Lights
24
Glove Chamber Negative Pressure Switch
25
Gas System Switch and Indicator Light
25
Light Switch and Indicator Light
25
Electrical Foot Switch (Optional)
25
Vacuum Pump Outlet
25
Catalyst Switch and Indicating Light
25
Power Switch and Indicator Light
26
Dial Thermometer
26
Variable/35°C Switch, Temp Control and Indicator Light
26
Temp Safety and Overtemp Indicator Light
26
Disposable Anaerobic Indicator Strips
27
Maintenance
28
Applying Preservative to Vinyl Front
28
Leak Detection
28
Checking the Interchange
29
Checking the Chamber
29
Removing the Gloves
29
Regenerating the Wafers
30
Replacing the Charcoal Filter
30
Gas Saving Hints
30
Service
33
Install the Add-On Module
33
Join the Glove Chambers
33
Reassemble the Unit
34
35°C Setpoint Controller Check
34
35°C Setpoint Calibration
34
Calibrate the 35°C Controller
34
Variable Setpoint Controller Check and Calibration
35
Replace Fluorescent Light Bulbs
35
Reverse Vacuum Solenoid Valve (In-House Vacuum)
35
Replace the Temperature Probe
36
Adjust the Pressure Switches
37
Adjust the Interchange Cycle
37
Replace Interchange Door Gaskets
38
Replace an Indicator Light
39
Replace the Circulation Fan Motor
39
Troubleshooting
40
Leak-Check Anaerobic Interchange
40
Leak-Check Anaerobic Glove Chamber
41
Adjustment and Part Installation
41
Outer Door Latch Alignment
41
Outer Door Hinge Alignment
42
Inner Door Latch Adjustment
42
Outer Door Switch Adjustment
43
Inner Door Switch Adjustment
44
Interchange Leaks - Troubleshooting Chart
44
General Troubleshooting Chart
45
Specifications
47
Parts List
49
Advertisement
Thermo Scientific Matrix 1029 User Manual (66 pages)
Electronic Pipette
Brand:
Thermo Scientific
| Category:
Laboratory Equipment
| Size: 1 MB
Table of Contents
Table of Contents
3
Congratulations
6
Before You Begin
6
Introduction
7
Thermo Scientific Matrix Single Channel Pipette
8
Thermo Scientific Matrix Multichannel Pipette
8
Pipette Overview
9
Components
9
General Description
10
Keypad
11
Operation Keys
11
Programming Keys
12
Special Function Key
13
Display
15
Pipette Specifications
16
Hazards And Precautions
17
Programming and Operation
18
Programming The Electronic Pipette
18
Open Programming Mode Or "Scratch Pad" (P-0)
18
Entering A Program In Open Programming Mode
18
Storing A Program
21
Program Recall
22
Adjusting Pipetting Speed
22
Reviewing The Program
22
Programming Examples
23
Sample Transfers
23
Incremental Pipetting
24
Serial Dilutions
24
Simple Dilutions
25
Supernatant Collection
25
Operating Procedures
26
Calibration
28
Volume Measurement
28
Pipette Calibration
29
Factory Calibration Step
29
Easy" Cal Mode
29
Calc" Mode
30
Calview
32
Calreset
32
Recommendations For Accurate Pipetting
32
Troubleshooting
34
Maintenance
36
Single Channel Maintenance
37
Single Channel Disassembly
37
Single Channel Cleaning And Autoclaving
39
Pipette Reassembly
39
Multichannel Maintenance
40
Multichannel Disassembly
40
Multichannel Cleaning And Autoclaving
43
Multichannel Maintenance And Reassembly
43
Installing/Replacing Batteries
49
Installing/Replacing Nimh Batteries
49
Installing/Replacing Lithium-Ion Battery (16 Ch)
53
Charging/Recharging Batteries
55
Charging/Recharging Nimh Batteries
55
Charging/Recharging Lithium-Ion Battery (16 Ch)
56
Technical Service
58
Instrument Warranty
58
Expert Pipette Service
59
On Site Pipette Service Options
60
Recommended Equipment Decontamination Methods
61
Tips And Reservoirs
63
Advertisement
Related Products
Thermo Scientific Phadia 100
Thermo Scientific Matrix 1020
Thermo Scientific Matrix 1021
Thermo Scientific Matrix 1022
Thermo Scientific Matrix 1024
Thermo Scientific 108004-00
Thermo Scientific GENESYS 10S Vis
Thermo Scientific 1025
Thermo Scientific BIOShield 1000A
Thermo Scientific 103261
Thermo Scientific Categories
Laboratory Equipment
Measuring Instruments
Freezer
Accessories
Refrigerator
More Thermo Scientific Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL