Sign In
Upload
Manuals
Brands
SystemAir Manuals
Air Handlers
Danvent TIME
SystemAir Danvent TIME Manuals
Manuals and User Guides for SystemAir Danvent TIME. We have
3
SystemAir Danvent TIME manuals available for free PDF download: Annex For The User Manual, User Manual
SystemAir Danvent TIME User Manual (60 pages)
Air Handling Units with control system
Brand:
SystemAir
| Category:
Air Handlers
| Size: 2 MB
Table of Contents
Table of Contents
3
Manufacturer
10
B. Name Of Machines
10
C. Declaration Of Conformity - Example
11
D. General Descriptions, Dangers And Warnings
12
D.1 Overview Via Pictograms on the Inspection Side of the Unit
12
D.1.1 Where Are Pictograms Placed on the Units
13
D.1.2 CE Label - Example for DV Unit
14
D.1.3 CE Label - Example for TIME Unit
14
D.1.4 Pictogram on a Door for a Fan in a DV Unit
14
D.1.5 Pictogram on a Door for a Fan in a TIME Unit
14
D.1.6 Pictograms for All Available Functions in the Units
15
D.1.7 Pictograms about Warnings and Dangers on the Units
16
D.2 Data about the Unit According to Cards and Labels in and on the Unit
17
D.2.1 Machine Card with Unique Data on Every Unit
17
D.2.2 Label with Data about the Cabinet
18
D.2.3 Flowchart - Example of the Label Placed on or with the Cabinet
18
D.2.4 Symbols in the Flowchart and Explanation about the Symbols
19
D.2.5 Example of Label Placed on or with the Cabinet - Terminal Plan for External
20
Components
20
D.3 Hand Terminal (Optional for DV Units - Always Standard for TIME Units)
20
D.4 Dimensions of the Units - Selected Examples
21
D.5 Ordinary Automatically Operation - Only Manual Operation by New Parameters
22
D.6 Warnings about Dangers
22
Drawings, Diagrams, Guides and Instructions for the Use, Maintenance and Repair
22
Unintended Use And Misuse - Inappropriate Applications For The Machine
23
23
H.1 Air Handling Unit in Operation
23
Employees In Charge Of Operation/Control/Maintenance
23
F1. Employees That Take Care Of Ordinary Operation
23
Intended Use And Range Of Applications
23
Instructions for Unloading on the Site as Well as Installation and Connection
24
I.1. Unloading on the Site
24
I.1.1 Unloading by Fork-Lift Truck
24
I.1.2 Unloading by Crane
24
I.1.3 Transport of Unit Without Base Frame on the Site
24
I.1.4 Lifting a Unit with Straps
24
I.1.5 Lifting a Unit with Preinstalled Brackets on the Base Frame for Lifting
25
I.1.6 Roof Unit with Bitumen Roof
25
I.1.7 Roof Unit with Steel Roof
25
I.1.8 Pre-Assembly Storage
26
I.1.9 Tilt Less than 30˚ During Transportation of the Section with Cooling Compressor - DVU or DVU-C
26
I.2. Installation - Mechanical
26
I.2.1 Free Area in Front of and above the Unit
26
I.2.2 Supporting Surface
26
I.2.3 Adjustable Feet under Legs or Base Frame and Transport of Sections
26
I.2.4 Base Frame Assembly
26
I.2.5 Base Frames for Outdoor Units
27
I.2.6 Installation on the Site of Unit Sections at the Base Frame When Sections Are Delivered on Pallets
27
I.2.7 Joining the AHU Sections
29
I.2.8 Fitting the Ductwork
30
I.2.9 Risk of Stack Effect by Vertical Ducts and Wind Pressure on Louvers
30
I.2.10 Refitting of Guards
30
I.3. Installation - Electrical
31
I.3.1 Description
31
I.3.2 Wiring Diagrams
31
I.3.2.1 TIME Units - Labels on the Cabinet Next to the Supply Fan
31
I.3.2.2 DV Units - Labels on or with the Cabinet
31
I.3.3 Installation of Mains Power Supply
31
I.3.3.1 Necessary Mains Power Supply for TIME Units with Ec Motors and Without DVU
31
I.3.3.2 Necessary Mains Power Supply for DV Units with Cabinet/Control System
32
I.3.3.3 Necessary Overvoltage Protection Device, that Leads Lightning Overvoltage to an Earth Lead on a Safe Way
32
I.3.4 Electrical Connection of Components and Functions
32
I.3.4.1 Connection of the Systemair Control Panel to the Corrigo E28 Controller - Software Version 3.3
32
I.4 Installation - Pipes for Water - Hot and Chilled, Valves and Drains
33
I.4.1 Description
33
I.4.2 Pipe Connections
33
I.4.3 Possibility of Extracting Components from the Unit
33
I.4.4 Pipe Connections to Batteries
33
I.4.4.1 Heating Coils
33
I.4.4.2 Cooling Coils
34
I.4.4.3 Rigid Bearings for Valves, Circulation Pumps and Pipe System
34
I.4.4.3.1 Pipe Connection to Heating Coils
34
I.4.4.3.2 Pipe Connection to Cooling Coils for Chilled Water
35
I.4.4.3.3 Valve Motor and Valve for Heating
35
I.4.4.3.4 Valve Motor and Valve for Cooling
35
I.4.5 Draining Condensate Water
35
I.4.6 Draining Condensate Water from Plate Heat Exchanger
36
I.4.7 Draining Condensate Water from Cooling Battery
36
Installation and Assembly Instructions for Reduction of Noise and Vibration Emissions
36
Instructions for Putting into Service, Adjustments, Use and Commissioning
37
K.1 Print-Outs on Paper
37
K.2 Electronic Media
37
K.3 Documentation Is Available for Download from Https://Techdoc.systemair.dk
38
K.4 Start-Up by Installer
38
K.4.1 Checklist, Relevant Values
38
K.4.1.1 Checklist Prior to Start-Up
38
K.4.1.2 Switch on Power
38
K.5 Adjustments and Use
38
K.6 Description of Functions
38
K.6.1 Remote Control
38
K.6.1.1 Communication WEB-Master (TCP/IP Exoline) to PC and Android Telephone
38
K.6.1.2 Communication to BMS Systems with MODBUS
39
K.6.1.3 Communication to BMS Systems with LON
39
K.6.1.4 Communication to BMS Systems Via Bacnet
39
K.6.2 Extended Operation and External Start/Stop (for Example by Presence Detectors)
39
K.6.3 Valve and Valve Motor for Heating Coil
39
K.6.4 Valve and Valve Motor for Cooling Coil
39
K.6.5 DX Cooling
39
K.6.6 Circulation Pump, Heating
39
K.6.7 Fire Alarm Function
40
K.6.7.1 External Fire Signal that Indicate Block or Run
40
K.6.7.2 External Fire Signal
40
K.6.7.3 Two Fire Thermostats
40
K.6.7.4 One Smoke Detector in Extract Air
40
K.6.8 E Tool - Configuration Tool
40
K.6.9 Electrical Heater Battery
40
K.6.9.1 Control of Heating Capacity Connected to Unit with Systemair Control System
40
K.6.9.2 Control of Heating Capacity Connected to Unit Without Systemair Control System
40
K.6.10 Speed Control of Fans
41
K.6.10.1 TIME Control System - EC Motors
41
K.6.10.2 DV Control System - Frequency Converters Inside the Unit Are IP 20
41
K.6.10.3 Pressure Transmitters
41
K.6.10.4 CO2-Dependent Air Flow
41
K.6.10.5 Humidity Dependent Air Flow
41
K.6.11 Cabinet
41
K.6.11.1 Integrated Cabinets in TIME Units
41
K.6.11.2 Integrated Cabinet in DV Units with Control System
41
K.6.11.3 Cabinet Placed on the DV Unit with Control System
41
K.6.13 Damper Motors
42
K.6.14 Filter Guards
42
K.6.15 Room Temperature Sensors
42
K.6.16 Frost Protection
42
K.6.17 Systemair Control Panel - SCP
42
K.6.18 Cooling Recovery
42
K.6.19 Free Cooling
42
K.6.20 Alarm Signal
43
K.6.21 Heat Recovery
43
K.6.22 Frost Protection - Plate Heat Exchanger
43
K.7 Commissioning
43
Information about the Residual Risks that Remain Despite the Inherent Safe Design Measures, Safeguarding and Complementary Protective Measures Adopted
43
L.1 Unit Casing
43
L.1.1. Design of the Machine to Make Transport Safe
43
L.2 Common for All Unit Sections
43
L.2.1 Risk Caused by Surfaces, Edges and Corners
43
L.3 Common for All Unit Sections by Insufficient Lighting
44
L.3.1 Risk Caused by Insufficient Lighting Inside Sections
44
L.4 Dampers Type DVA - DVB - DVM - DVP - Bypass Dampers in DVQ
44
L.4.1 Risk Caused by Maintenance and Cleaning of Dampers
44
L.5 Attenuators Type DVD
44
L.5.1 Risk Caused by Maintenance and Cleaning of Attenuators
44
L.6 Filters Type DVG - DVF
44
L.6.1 Risk Caused by Missing Change of Filters
44
L.6.2 Risk Caused by the Execution of Filter Change
45
L.7 Plug Fans Type DVE
45
L.7.1 Risk Caused by Lightning Strike
45
L.7.2. Risk Caused by Permanent Magnet Motor
45
L.7.3 Risk of Rotating Impeller Caused by Stack Effect (Chimney Effect)
45
L.8 Batteries for Heating and Cooling Type DVR - DVH - DVK, Cooling Compressor
46
L.8.1 Extreme Temperatures - Heating
46
L.8.2 Extreme Temperatures - Cooling
46
L.9 Cooling Compressor Units Type DVU - DVU-C
46
L.9.1 Risk of High Temperature
46
L.9.2 Risk Caused by Lightning Strike
46
Instructions on the Protective Measures to be Taken by All Service Technicians During Repair and Maintenance
46
The Essential Characteristics of Tools Which May be Fitted to the Machinery
47
The Conditions of Stability During Use, Transportation, Assembly, Dismantling When out of Service
47
O.1 Installed Reliable to Avoid Units to be Tilted or Moved by the any Storm
47
O.2 Transport of Section with Cooling Compressor Unit
47
O.3 Disposal of the Cooling Compressor System - Type DVU and DVU-C
47
O.4 Generel Disassembly - Sharp Edges
47
P. Instructions For Machinery Where These Are Regularly To Be Transported
48
The Operating Method to be Followed in the Event of Breakdown. Safe Restart
48
Adjustment And Maintenance Operations
48
R.1 Shutdown of the Unit to a Safe State
48
R.2 Recommended Maintenance Intervals
49
R.3. Filters - Sizes and Numbers
50
R.3.1 Bag Filters
51
R.3.2 Panel Filters
51
R.4. Changing the Internal Battery in the Controller
51
R.5 Other Functions to Maintain
52
R.5.1 the Unit
52
R.5.2 Dampers
52
R.5.3 Rotary Heat Exchanger DVC
53
R.5.3.1 Rotor
53
R.5.3.2 Motor and Belt Drive
53
R.5.4 Cross Flow and Counter Flow Exchanger
53
R.5.4.1 By-Pass Damper
54
R.5.4.2 Condensate Water Drain
54
R.5.5 Run-Around Heat Exchanger DVR
54
R.5.5.1 Pump and Pressure Expansion
54
R.5.5.2 Condensate Water Drain
54
R.5.6 Heating Coil DVH, Cooling Coil DVK and Change over Coil DVHK
55
R.5.6.1 Heating Battery
55
R.5.6.2 Cooling Battery
55
R.5.6.3 Electeric Heating Battery
55
R.5.7 Plug Fans DVE
55
R.5.7.1 Motor
55
R.5.8 Silencer DVD
55
R.5.9 Outdoor Air Section DVY
56
R.5.10 Cooling Compressor Units DVU and DVU-C
56
R.5.10.1 Cooling Compressor Circuit
57
R.5.10.2 Built-In Control System
57
R.5.10.3 Maintenance of Built-In Control System
57
Instructions Designed to Enable Adjustment and Maintenance to be Carried out Safely, Including the Protective Measures that Should be Taken During These Operations
57
S.1. Protective Measures and Additional Protective Measures
57
S.1.1 Necessary Protection Measures Prior to Start-Up
58
S.1.1.1 Design of Protection Measures
58
S.1.1.2 Configuration of Frequency Converters with Installed Guard
58
S.1.2 Safe Adjustment and Maintenance
58
S.1.3 Personal Protective Equipment for Maintenance Staff - Health and Safety
58
The Specifications of the Spare Parts to be Used, When These Affect the Health and Safety of Operators
59
T.1 Spare Parts - Mechanical
59
T.2 Spare Parts - Electrical
59
Information On Airborne Noise Emissions Exceeding 70 Db(A)
59
Annex 1 Declaration Of Conformity With Unique Production Number
59
Advertisement
SystemAir Danvent TIME User Manual (36 pages)
Air Handling Units
Brand:
SystemAir
| Category:
Air Handlers
| Size: 1 MB
Table of Contents
Description of the Air Handling Units
3
Table of Contents
4
Intended Use, Noise and Vibration
4
Protection and Safety Measures
5
1 Manufacturer
8
Manufacturer, Supplier Data
8
Name of Machines
8
2 Declaration of Conformity
9
Electrical Connection
10
3 Description of the Air Handling Units - 8 Models
10
Common for All Air Handling Unit Models
10
Specific Data about each Model of the Air Handling Unit - 8 Models
10
DV Unit Without Switchboard/Control System
10
TIME Unit - Indoor Model
10
TIME Unit - Outdoor Model
11
DV Unit with Switchboard/Control System - Delivered in Several Sections
11
DV Unit with Switchboard/Control System - Delivered as One Section on Base Frame
12
DV Unit with Switchboard and Control Components, Without Controller - Delivered in Several Sections
12
DV Unit with Switchboard and Control Components, Without Controller - Delivered as One Section on Base Frame
13
DVU - Section (Cooling Unit)
14
4 Intended Use, Noise and Vibration
20
Intended Use and Range of Applications
20
Unintended Use and Misuse - Inappropriate Applications for the Machine
20
Air Handling Unit in Operation
20
Maintenance, Repair, Dismantling and Disposal
20
Protective Measures
20
Sharp Edges
20
Filters
20
Disposal Measures
20
DVU - Cooling System
21
Sharp Edges
21
Use/Operation of the Machine
21
Prohibited Use of the Machine
21
Noise and Vibration
21
5 Protection and Safety Measures
22
Protection Measures and Additional Protection Measures
22
Necessary Protection Measures Prior to Start-Up
22
Design of Protection Measures
22
Configuration of Frequency Converters with Inspection Doors Closed
22
Safe Adjustment and Maintenance
22
Safety Precautions During Adjustment and Maintenance
22
Personal Protective Equipment for Maintenance Staff - Health and Safety
22
6 Electrical Installation
23
Description
23
Wiring Diagrams
23
Wiring Diagrams for Time Units
23
Wiring Diagrams for DV Units with Switchboard/Control System
23
Wiring Diagram for DV Units with Switchboard and Control Components but Without the Intelligent Controller
23
Installation of Mains Power Supply
24
Necessary Mains Power Supply for TIME Units
24
Necessary Mains Power Supply for DV Units with Switchboard/Control System
24
Electrical Connection of Components and Functions
24
Repeater
24
Extended Operation
24
Valve and Valve Motor for Heating Coil
25
Valve and Valve Motor for Cooling Coil
25
DX Cooling
25
Circulation Pump, Heating
25
Fire Protection Function
25
Communication with BMS Systems
26
E Tool Programme
26
Electrical Heater Battery
26
Frequency Converter
26
Pressure Transmitters
27
Switchboard
27
Temperature Sensors
27
Damper Motors
27
Filter Guards
27
Room Temperature Sensors
27
Frost Protection
28
Systemair Control Panel
28
Cooling Recovery
28
Free Cooling
28
Alarm Signal
28
Heat Recovery
28
Frost Protection - Plate Heat Exchanger
28
7 Plumbing
29
Description
29
Pipe Connections
29
Possibility of Extracting Components from the Unit
29
Pipe Connections to Batteries
29
Heating Coils
29
Cooling Coils
29
Rigid Bearings for Valves, Circulation Pumps and Pipe System
29
Draining Condensate Water
30
Draining Condensate Water from Plate Heat Exchanger
30
Draining Condensate Water from Cooling Battery
31
8 Accompanying Documents
31
Print-Outs on Paper
31
DV Unit Without Switchboard
31
TIME and DV Units with Switchboard/Control System
31
DV Units with Switchboard and Control Components - Without Controller
32
Electronic Media
32
9 Start-Up
33
Checklist, Relevant Values
33
Checklist Prior to Start-Up
33
Switch on Power
33
Enter Relevant Values in the Controller
33
DVU - Wiring Diagram for Internal Controller
34
Menu for Internal Controller in the DVU
35
SystemAir Danvent TIME Annex For The User Manual (76 pages)
Air handling units With control system
Brand:
SystemAir
| Category:
Air Handlers
| Size: 3 MB
Table of Contents
Table of Contents
3
Annex 4. Assemble Base Frames - Height 150 MM for Units Sizes 10-40
9
Base Frame Length 2420 - 4590 [MM] Unit Size 50-150
15
Base Frame Length 4590 - 6200 [MM] Unit Size 50-150
16
Annex 6. Assemble Base Frames - Height 250 MM for Units Sizes 10-40
17
Base Frame Length 720 - 2420 [MM] Unit Size 10-40
18
Base Frame Length 2420 - 4590 [MM] Unit Size 10-40
19
Base Frame Length 4590 - 6200 [MM] Unit Size 10-40
20
Annex 8. Installation of Steel Roof in the Sizes 10-150
21
Overview
21
Mount Rails. Units of Size 10, 15, 20, and 25
22
Roof Overhang Along The Long Sides Of The Unit
23
Calculation Of The Overhang At The Ends Of The Unit. Mount Overhang Profile - G1
23
Foam Bands Between Rails And Roof Plates - Mount Roof Plates
26
Foam Bands Between Roof Plates
26
Mount Roof Plates - Some Of Them Are Overlapping By 2 Ribs
26
Mount Overhang Profile - G5 On The Other End Of The Unit
26
Mount Side Profiles And Corners Along The Edges Of The Roof To Protect Persons
27
Apply Sealing On Plate Joints To Ensure Water Resistance
27
Annex 9. Speed Control for Rotor and Assembly of Divided Rotor
29
Speed Control
29
Selection of Correct Signal Via the 4 DIP Switch Levers
29
Indication of Operation Mode Via Red and Green LED as Well as Test of Motor
30
Copy of the Label with Information about Connection of Cables
31
Assemble The Systemair Casing For Dv60, Dv80, Dv100, Dv120 Og Dv150
32
Assemble Divided Rotor For DV 60, DV 80, DV 100, DV 120 Og DV 150
36
Assemble Divided Rotor For DV 190 Og DV 240
47
Installation Of Motor That Turns Rotor And Sensor For Rotation
59
Annex 10. Internal Controller in the Cooling Compressor Units
62
DVU - Section (Cooling Unit)
62
DVU-Internal Controller For The Cooling Compressor System
63
Background Illumination Of The Display
63
Potentiometer On The Internal Controller For The Cooling Compressor System
63
Selection Of Menu
63
Change Parameters
63
Menu - Drawing Of The Menu To Guide The User
64
The Start Display
64
Settings
64
Automatic Resets Of The High Pressure Switch
64
Polarity
64
Hotgas - Setting Of Period
64
Limiter
64
Service
64
Manual Operation
64
Running Hours And Hotgas Activations
64
Alarm Log
65
Modified Software In Danfoss Frequency Converter For The Compressor
65
Maintenance
65
Cooling Capacity and Absorbed Power Consumption in Kw for Compressor - EER Factor
66
Power Consumption For The Fans
66
Data Plate
66
DVU-C - Section - Cooling Unit With Cooling Recovery
67
Annex 11. Menu for Internal Controller in Cooling Compressor
68
Annex 12. Connection of Fan Motor and Set-Up for Frekv. Conv
69
Connection Of Fan Motor
69
Set-Up For Danfoss Fc101 For DV-Units With Ac Motors
70
Setup Danfoss Fc101 for DV‐Units
70
AC-Fan Operation Without Thermistor For Danfoss Fc101
72
Set-Up Danfoss Fc101 For DV-Units With Pm Motors
73
Advertisement
Advertisement
Related Products
SystemAir Danvent DV
SystemAir Danvent DV-15
SystemAir Danvent DV-20
SystemAir Danvent DV-30
SystemAir Danvent DV-40
SystemAir DANVENT DV50
SystemAir DANVENT DV80
SystemAir DANVENT DV190
SystemAir DANVENT DV240
SystemAir DVV-XS
SystemAir Categories
Fan
Air Handlers
Ventilation Hood
Air Conditioner
Fire and Smoke Dampers
More SystemAir Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL