Sign In
Upload
Manuals
Brands
Sonel Manuals
Measuring Instruments
MRU-30
Sonel MRU-30 Manuals
Manuals and User Guides for Sonel MRU-30. We have
4
Sonel MRU-30 manuals available for free PDF download: User Manual, Operation Manual
Sonel MRU-30 User Manual (56 pages)
EARTH RESISTANCE METR
Brand:
Sonel
| Category:
Measuring Instruments
| Size: 3 MB
Table of Contents
Table of Contents
5
Safety
7
Turning the Meter on and Activating the Screen Backlight
8
Meter Configuration
8
Measurements
11
Measurement of AC+DC Interfering (Noise) Voltages
11
Earth Resistance Measurement with 2-Pole Method (R 2P)
12
Earth Resistance Measurement with 3-Pole Method (R 3P)
13
Earth Resistance Measurement with 4-Wire Method
17
Earth Resistance Measurement with 3-Pole Method with Additional Clamp (R E 3P+C)
20
Earth Resistance Measurement with Two-Clamp Method (2C)
24
Calibration of the Measurement Clamp C-3
26
Measurement of Resistance of Protective Conductors and Equipotential Bonding
28
Cont )
28
Calibration of the Test Leads for R
30
CONT Measurement
30
Earth Resistivity Measurement (Ρ)
31
Memory of Measurement Results
35
Storing the Measurement Results in the Memory
35
Viewing Memory Data
37
Deleting Memory Data
38
Deleting Cell Data
38
Deleting Bank Data
39
Deleting the Whole Memory
41
Data Transmission
42
Computer Connection Accessories
42
Data Transmission through USB Port
42
Firmware Update
43
Power Supply of the Meter
43
Monitoring the Power Supply Voltage
43
Charging the Rechargeable Battery Pack
44
General Principles of Using Ni-MH Batteries
45
Cleaning and Maintenance
45
Storage
45
Dismantling and Disposal
46
Technical Specifications
46
Basic Data
46
Additional Data
49
Influence of the Serial Interference Voltage U
49
Influence of the Auxiliary Electrodes on Earth Resistance Measurements for Methods R E 3P, R E 4P, R E
49
C, Ρ
49
Z on Earth Resistance Measurements for 3P+C, Ρ
49
Influence of the Interference Current I
49
R E 3P+C
49
Influence of Interference Current on the Result of the Earth Resistance Measurement for Two-Clamp Method (2C)
50
Influence of the Relation of the Resistance Measured with Clamp for the Multiple Earthing Branch to the Resultant Resistance
50
Additional Uncertainties in Accordance with IEC 61557-5
50
E 3P+C)
50
E 3P, R E 4P)
50
Accessories
51
Standard Accessories
51
Optional Accessories
51
Manufacturer
52
Laboratory Services
53
Advertisement
Sonel MRU-30 Operation Manual (56 pages)
Earth Resistance Meter
Brand:
Sonel
| Category:
Measuring Instruments
| Size: 2 MB
Table of Contents
Operating Manual
3
Table of Contents
5
1 Safety
7
2 Turning the Meter on and Activating Screen Backlit
8
3 Meter Configuration
8
4 Measurements
11
Measurement of AC+DC Interfering (Noise) Voltages
11
Measurement of Earth Connection and Equipotential Bonding (2P)
12
Measurement 3P
13
Measurement 4P
16
Measurement 3 P + Clamp
20
Two-Clamp Measurement
23
Calibration of the Measurement Clamp C-3
25
Measurement of Earth Connection and Equipotential Bonding (200Ma)
27
Calibration of the Test Leads for Rcont Measurement
29
Earth Resistivity Measurement
30
5 Memory of Measurement Results
34
Storing the Measurement Results in the Memory
34
Viewing Memory Data
36
Deleting Memory Data
36
Deleting Cell Data
36
Deleting Bank Data
38
Deleting the Whole Memory
39
6 Data Transmission
41
Computer Connection Accessories
41
Data Transmission through Usb Port
41
7 Firmware Update
42
8 Power Supply of the Meter
42
Monitoring the Power Supply Voltage
42
Charging the Rechargeable Battery Pack
43
General Principles of Using Ni-MH Batteries
44
9 Cleaning and Maintenance
45
10 Storage
45
11 Dismantling and Disposal
45
12 Technical Specifications
46
Basic Data
46
Additional Data
49
Influence of the Serial Interference Voltage U
49
Measurements for Functions 3P, 4P, 3P + Clamp, Ρ
49
Z on Earth Resistance
49
Functions 3P, 4P, 3P + Clamp, Ρ
49
Influence of the Interference Current I
49
Measurement 3P+Clamp
49
Influence of Interference Current on the Result of the Earth Resistance Measurement Using Double Clamps
50
Influence of the Relation of the Resistance Measured with Clamp for the Multiple Earthing Branch to the Resultant Resistance (3P + Clamp)
50
Additional Uncertainties in Accordance with IEC 61557-5 (3P, 4P)
50
13 Accessories
51
Standard Accessories
51
Additional Accessories
51
14 Manufacturer
52
15 Testing and Calibration Laboratory
53
Sonel MRU-30 User Manual (56 pages)
Earth resistance meter
Brand:
Sonel
| Category:
Measuring Instruments
| Size: 2 MB
Table of Contents
Table of Contents
5
1 Safety
7
2 Turning the Meter on and Activating Screen Backlit
8
3 Meter Configuration
8
4 Measurements
11
Measurement of AC+DC Interfering (Noise) Voltages
11
Earth Resistance Measurement with 2-Pole Method (R 2P)
12
Earth Resistance Measurement with 3-Pole Method (R 3P)
13
Earth Resistance Measurement with 4-Wire Method (R 4P)
17
Earth Resistance Measurement with 3-Pole Method with Additional Clamp (R E 3P+C)
20
Earth Resistance Measurement with Two-Clamp Method (2C)
24
Calibration of the Measurement Clamp C-3
26
Measurement of Resistance of Earth Connection and Equipotential Bonding (RCONT )
28
Calibration of the Test Leads for R
30
Earth Resistivity Measurement (Ρ)
31
5 Memory of Measurement Results
35
Storing the Measurement Results in the Memory
35
Viewing Memory Data
37
Deleting Memory Data
38
Deleting Cell Data
38
Deleting Bank Data
39
Deleting the Whole Memory
41
6 Data Transmission
42
Computer Connection Accessories
42
Data Transmission through USB Port
42
7 Firmware Update
43
8 Power Supply of the Meter
43
Monitoring the Power Supply Voltage
43
Charging the Rechargeable Battery Pack
44
General Principles of Using Ni-MH Batteries
45
9 Cleaning and Maintenance
45
10 Storage
45
11 Dismantling and Disposal
46
12 Technical Specifications
46
Basic Data
46
Additional Data
49
Influence of the Serial Interference Voltage U
49
E 3P, R E 4P, R E
49
Influence of the Auxiliary Electrodes on Earth Resistance Measurements for Methods
49
R E 3P, R E 4P, R E 3P+C, Ρ
49
Influence of the Interference Current I
49
Influence of Interference Current on the Result of the Earth Resistance Measurement for Two-Clamp Method (2C)
50
Influence of the Relation of the Resistance Measured with Clamp for the Multiple Earthing Branch to the Resultant Resistance (R E 3P+C)
50
Additional Uncertainties in Accordance with IEC 61557-5 (R 3P, R 4P)
50
13 Accessories
51
Standard Accessories
51
Optional Accessories
51
14 Manufacturer
52
15 Laboratory Services
53
Advertisement
Sonel MRU-30 Operation Manual (52 pages)
Earth Resistance Meter
Brand:
Sonel
| Category:
Measuring Instruments
| Size: 2 MB
Table of Contents
Operating Manual
3
Table of Contents
5
1 Safety
7
2 Turning the Meter on and Activating the Screen Backlight
8
3 Meter Configuration
8
4 Measurements
11
Before Testing First Measure the Presence of Ac or DC
11
Interference (Noise) Voltages
11
Measurement of Earth Connection and Equipotential Bonding (2P)
11
Measurement 3P
13
Measurement Method
16
Clamp Measurement Method
20
Two-Clamp Measurement Method
23
Calibration of the Measurement Clamp C-3
26
Measurement of Earth Connection and Equipotential Bonding (200Ma)
27
Earth Resistivity Measurement
30
5 Memory of Measurement Results
33
Storing the Measurement Results in the Memory
34
Viewing Memory Data
35
Deleting Memory Data
36
Deleting Cell Data
36
Deleting Bank Data
38
Deleting the Whole Memory
39
6 Data Transmission
40
Computer Connection Accessories
40
Data Transmission through Usb Port
41
7 Firmware Update
41
8 Power Supply of the Meter
42
Monitoring the Power Supply Voltage
42
Charging the Rechargeable Battery Pack
42
General Principles of Using Ni-MH Batteries
43
11 Dismantling and Disposal
44
9 Cleaning and Maintenance
44
10 Storage
44
12 Technical Specifications
45
Basic Data
45
Additional Data
47
Influence of the Serial Interference Voltage U
47
Measurements for Functions 3P, 4P, 3P + Clamp, Ρ
47
Z on Earth Resistance
47
Functions 3P, 4P, 3P + Clamp, Ρ
48
Influence of the Interference Current I
48
Measurement 3P+Clamp
48
Influence of Interference Current on the Result of the Earth Resistance Measurement Using Double Clamps
48
Influence of the Relation of the Resistance Measured with Clamp for the Multiple Earthing Branch to the Resultant Resistance (3P + Clamp)
48
Influence of the Auxiliary Electrodes on Earth Resistance Measurements for Functions 3P, 4P, 3P + Clamp, Ρ
48
Additional Uncertainties in Accordance with IEC 61557-5 (3P, 4P)
49
13 Accessories
49
Standard Accessories
49
Additional Accessories
49
14 Manufacturer
50
Advertisement
Related Products
Sonel MRU-20
Sonel MRU-200
Sonel MRU-200-GPS
Sonel MRU-21
Sonel MRU-120HD
Sonel MRU-10
Sonel MRU-120
Sonel MRU-11
Sonel MRU-12
Sonel MPI-502F
Sonel Categories
Measuring Instruments
Test Equipment
Thermal cameras
Laboratory Equipment
Adapter
More Sonel Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL