Sign In
Upload
Manuals
Brands
SICK Manuals
Measuring Instruments
DUSTHUNTER SP100 Ex-3K
SICK DUSTHUNTER SP100 Ex-3K Manuals
Manuals and User Guides for SICK DUSTHUNTER SP100 Ex-3K. We have
2
SICK DUSTHUNTER SP100 Ex-3K manuals available for free PDF download: Operating Instructions Manual
SICK DUSTHUNTER SP100 Ex-3K Operating Instructions Manual (140 pages)
Scattered Light Dust Measuring Device
Brand:
SICK
| Category:
Measuring Instruments
| Size: 5 MB
Table of Contents
Table of Contents
3
1 About this Document
9
Function of this Document
9
Scope of Application
9
Target Groups
9
Further Information
9
Symbols and Document Conventions
10
Warning Symbols
10
Warning Levels and Signal Words
10
Information Symbols
11
Data Integrity
11
2 For Your Safety
12
Basic Safety Information
12
Warning Information on the Device
16
Information on the Sender/Receiver Unit
16
Information on the MCUDH Ex-3K Control Unit
17
Intended Use
18
Responsibility of User
19
3 Product Description
21
Product Identification
21
Product Characteristics
22
Layout and Function
22
Functional Principle
23
Protection Concept
24
DUSTHUNTER SP100 Ex-3K Sender/Receiver Unit
25
MCUDH Ex-3K Control Unit
27
Conventional MCU Control Unit
29
Flange with Tube
31
Non-Return Valve
31
Connection Line and Plug Protection Guard
32
Weather Hood Housing
32
Function Check
33
Explosion Protection in Accordance with ATEX
35
Operation in the Ex-Zone
35
Application Illustration DUSTHUNTER SP100 Ex-3K
36
Interfaces
37
Standard Interfaces of the MCUDH Ex-3K Control Unit
37
Standard Interfaces of the MCU Control Unit
38
SOPAS ET User Interface
38
4 Project Planning
39
Device Configuration
39
Selecting the Sender/Receiver Unit
39
Selecting the Flange with Tube
40
Selecting the Control Unit
41
Installation Location
42
Project Planning for Measuring Channel
42
Space Requirements for System Components
43
Purge Gas Supply
45
Project Checklist
46
5 Transport and Storage
47
Transport
47
Storage
47
6 Assembly
48
Assembly Information
48
Proper Assembly
48
Preparing the Measuring Point
48
Scope of Delivery
48
Installation Sequence
49
Fitting the Flange with Tube
50
High-Temperature Version
51
Fitting the Weather Hood Housing
52
Fitting the Control Unit
53
7 Electrical Installation
54
Electrical Installation Safety Information
54
Connection Overview
54
Connection Plan
55
Information on Connection Lines
56
Connecting the Sender/Receiver Unit
56
Connecting the Control Unit
57
MCUDH Ex-3K Control Unit Component Layout
57
MCU Control Unit Component Layout
58
Work to be Done
59
Processor Boards Connections of Control Units
60
Connection Line to Control Unit
61
Installing the Purge Gas Supply
61
Connecting Remote-Display 100
61
Connection to the MCUDH Ex-3K Control Unit
61
Communication Options
62
8 Commissioning
65
Safety Information on Commissioning
65
Requirements for Commissioning
65
Inserting and Switching on
66
Adapting the Sender/Receiver Unit to the Duct Geometry
66
Fitting and Connecting the Sender/Receiver Unit
66
Recognizing the Safe Operating State
67
9 Configuring
68
Prerequisites
68
Sopas Et
68
Install SOPAS ET
68
Password for SOPAS ET Menus
68
Changing the Password for SOPAS ET Menus
69
Connecting to the MCUDH Ex-3K Control Unit
69
Connection Via RS485 Service Interface
69
Connecting to the MCUDH Ex-3K Control Unit Via Ethernet
70
Configuring the RS485 Modbus ASCII/RTU Interface Module
71
Connecting a Remote Ethernet Interface Module
72
Connecting to the MCU Control Unit
72
Connection to Device Via Ethernet
72
Configuring the Interface Module of the MCU Control Unit
73
Configuring the MCU Control Unit Ethernet Module
74
System Configuration
75
Application Parameters
75
Assigning the Control Unit to the Sender/Receiver Unit
76
Factory Settings
77
Setting the Function Check
78
Setting the Analog Outputs Parameters
79
Setting the Analog Inputs Parameters
81
Setting the Response Time
82
Calibration for Dust Concentration Measurement
82
Calibration for Dust Concentration Measurement", Page
82
Set
82
Changing Display Settings
84
Finding the DUSTHUNTER COM Port
86
10 Operation
87
Operating Concept
87
User Groups
87
Set
87
MCUDH Ex-3K Displays and Operating Elements
88
MCUDH Ex-3K Control Unit Buttons
89
MCU Control Unit Displays and Operating Elements
90
11 Menus
91
MCU and MCUDH Ex-3K Control Units Menu Tree
91
Menu Tree "Menu
91
Set
92
Configuring on the Control Unit Display
93
Configuring Analog Outputs and Inputs of the Control Unit
93
Assigning the Control Unit to the Sender/Receiver Unit
93
Entering the Regression Coefficients
93
Enter the Level 1 Password
93
12 Maintenance
94
Set the Sender/Receiver Unit to "Maintenance": Click "Maintenance Sensor
94
Safety Information
95
Data Backup
96
Data Backup in SOPAS ET
96
Maintenance Plan
97
Consumables and Spare Parts
97
Maintenance on the Sender/Receiver Unit
97
Cleaning the Optics of the Sender/Receiver Unit
98
Checking the Contamination Value
99
Non-Return Valve
100
Test Equipment for Linearity Test
100
Power Supply Without Control Unit
100
Units
100
Maintenance Work on the Sender/Receiver Unit
101
Checking Laser Alignment
102
Replacing the Protection Tube O-Ring
103
Replacing the Seal in the Cleaning Opening
103
Replacing the Sinter Filter
104
Replacing the Flange Seal
104
Replacing the Potential Equalization Screw
105
Replacing the Protection Tube
105
Replacing the Hood
106
Replacing the Copper Seal of the Non-Return Valve
106
Replacing the Non-Return Valve
107
Maintenance Activities for MCUDH Ex Control Unit
108
Replacing the Button Cell in the Control Unit
108
Replacing the Ex Power Supply Unit
109
Replacing the RS485 Interface Module
110
MCU Control Unit Maintenance Work
111
Replacing the Button Cell in the Control Unit
111
Replacing the Interface Module
111
13 Troubleshooting
112
Safety Information
112
Monitoring and Diagnostic System
113
Status Display Leds
113
Sender/Receiver Unit Malfunctions
114
Malfunctions
114
Warning and Malfunction Messages
114
Control Unit Malfunctions
116
Malfunctions
116
Warning and Malfunction Messages
116
Control Unit Troubleshooting Measures
118
Setting the Laser Alignment
118
Filter
119
MCUDH Ex Control Unit Troubleshooting Measures
120
Replacing the Fuse
120
MCU Control Unit Troubleshooting Measures
121
Replacing the Fuse
121
Sending in Devices
121
14 Decommissioning
122
Switch-Off States
122
Switching off and Dismantling
122
Return Delivery
123
Disposal
123
15 Technical Data
124
Dimensional Drawings and Part Numbers
128
Dhsp100Ex-3K Sender/Receiver Unit
128
Flange with Tube
129
MCUDH Ex-3K Control Unit
130
MCU Control Unit
131
16 Spare Parts
133
Consumable Parts
133
Consumable Parts, DUSTHUNTER SP100 Ex-3K
133
Consumable Parts, MCUDH Ex-3K / MCU Control Unit
133
Spare Parts
134
Spare Parts, DUSTHUNTER SP100 Ex-3K
134
Spare Parts, Control Unit
134
17 Accessories
135
Weather Hood Housing
135
Connection Technology
135
Sender/Receiver - Control Unit Line
135
Fastening Technology
135
Optional Accessories
136
Options for MCUDH Ex-3K Control Unit
136
Options for MCU Control Unit
136
Other Accessories
136
Device Check Accessories
136
18 Annex
137
Compliances
137
Electrical Protection
137
Approvals
137
Licenses
138
Advertisement
SICK DUSTHUNTER SP100 Ex-3K Operating Instructions Manual (134 pages)
Scattered Light Dust Measuring Device
Brand:
SICK
| Category:
Measuring Instruments
| Size: 5 MB
Table of Contents
Table of Contents
3
About this Document
9
Function of this Document
9
Scope of Application
9
Target Groups
9
Further Information
9
Symbols and Document Conventions
10
Warning Symbols
10
Warning Levels and Signal Words
10
Information Symbols
11
Data Integrity
11
For Your Safety
12
Basic Safety Information
12
Warning Information on the Device
15
Information on the Sender/Receiver Unit
15
Information on the MCUDH Ex-3K Control Unit
16
Intended Use
17
Responsibility of User
18
Product Description
20
Product Identification
20
Product Characteristics
21
Layout and Function
21
Functional Principle
22
Protection Concept
23
DUSTHUNTER SP100 Ex-3K Sender/Receiver Unit
24
MCUDH Ex-3K Control Unit
26
Conventional MCU Control Unit
28
Flange with Tube
30
Purge Gas Supply
30
Connecting Cable and Plug Protection Bracket
31
Weather Protection Hood
31
Function Check
32
Explosion Protection in Accordance with ATEX
34
Operation in Potentially Explosive Atmosphere
34
Application Illustration DUSTHUNTER SP100 Ex-3K
35
Interfaces
36
Standard Interfaces of the MCUDH Ex-3K Control Unit
36
Standard Interfaces of the MCU Control Unit
37
SOPAS et User Interface
37
Project Planning
38
Device Configuration
38
Selecting the Sender/Receiver Unit
38
Selecting the Flange with Tube
39
Selecting the Control Unit
40
Installation Location
41
Project Planning for Measuring Channel
41
Space Requirements for System Components
42
Purge Gas Supply
44
Project Checklist
46
Transport and Storage
47
Transport
47
Storage
47
Mounting
48
Mounting Information
48
Proper Mounting
48
Preparing the Measuring Point
48
Scope of Delivery
48
Installation Sequence
48
Fitting the Flange with Tube
49
Fitting the MCUDH Ex-3K Control Unit
50
Fitting the Optional Remote Display 100
50
High-Temperature Version
51
Fitting the Weather Protection Hood
52
Electrical Installation
53
Electrical Installation Safety Information
53
Connection Overview
53
Connection Plan
54
Information on Connecting Cables
55
Connecting the Sender/Receiver Unit
56
Connecting the Control Unit
56
MCUDH Ex-3K Control Unit Components
56
MCU Control Unit Components
57
Remote Display 100 Components
57
Work to be Done
58
Processor Boards Connections of Control Units
59
Connecting Cable to Control Unit
60
Installing the Purge Gas Supply
60
Connecting Remote Display 100
60
Connecting to the MCUDH Ex-3K Control Unit
60
MCHDH Communication Options
61
Commissioning
64
Safety Information on Commissioning
64
Requirements for Commissioning
64
Inserting and Switching on
65
Adapting the Sender/Receiver Unit to the Duct Geometry
65
Fitting and Connecting the Sender/Receiver Unit
65
Recognizing the Safe Operating State
66
Configuring
67
Prerequisites
67
Sopas et
67
Install SOPAS et
67
Password for SOPAS et
67
Changing the Password for SOPAS et Menus
67
Connecting to the MCUDH Ex-3K Control Unit
68
Connection Via RS485 Service Interface to USB
68
Connection MCUDH Ex-3K Via RS485 Ethernet
68
Connecting a Separate Ethernet Interface Module
68
Configuring the RS485 Modbus ASCII/RTU Interface Module
69
Connecting to the MCU Control Unit
70
Connection to the MCU Via Ethernet
70
Configuring the Interface Module of the MCU Control Unit
70
System Configuration
71
Configuring the MCU Control Unit Ethernet Module
71
Application Parameters
71
Assigning the Control Unit to the Sender/Receiver Unit
72
Factory Settings
73
Setting the Function Check
73
Setting the Analog Outputs Parameters
74
Setting the Analog Inputs Parameters
76
Setting the Response Time
77
Gravimetric Comparison Measurement / Calibration
77
Changing Display Settings
79
Finding the DUSTHUNTER COM Port
81
Operation
82
Operating Concept
82
User Groups
82
MCUDH Ex-3K Displays and Operating Elements
82
MCUDH Ex-3K Control Unit Buttons
83
MCU Control Unit Displays and Operating Elements
83
Menus
84
MCU and MCUDH Ex-3K Control Units Menu Structure
84
Configuration (Menu)
84
Configuring on the Control Unit Display
86
Configuring Analog Outputs and Inputs of the Control Unit
86
Assigning the Control Unit to the Sender/Receiver Unit
86
Entering the Regression Coefficients
86
Maintenance
87
Safety Information
88
Data Backup
89
Data Backup in SOPAS et
89
Maintenance Plan
90
Consumables and Spare Parts
90
Maintenance on the Sender/Receiver Unit
90
Cleaning the Optics of the Sender/Receiver Unit
91
Checking the Contamination Value
92
Non-Return Valve
93
Test Equipment for Linearity Test
93
Maintenance Work on the Sender/Receiver Unit
94
Checking Laser Alignment
95
Replacing the Protection Tube O-Ring
96
Replacing the Seal in the Cleaning Opening
96
Replacing the Sinter Filter
97
Replacing the Flange Seal
97
Replacing the Potential Equalization Screw
98
Replacing the Protection Tube
98
Replacing the Hood
99
Replacing the Copper Seal of the Non-Return Valve
99
Exchanging the Non-Return Valve
100
Maintenance Tasks for MCUDH Ex-3K Control Unit
101
Replacing the Button Cell in the Control Unit
101
Replacing the MCUDH Ex-3K Power Supply Unit
102
Replacing the RS485 Interface Module
103
MCU Control Unit Maintenance Work
104
Replacing the Button Cell in the Control Unit
104
Replacing the Interface Module
104
Troubleshooting
105
Safety Information
105
Monitoring and Diagnostic System
106
Status Display LED and Display
106
Sender/Receiver Unit Malfunctions
107
Malfunctions
107
Warning and Malfunction Messages
107
Control Unit Malfunctions
109
Malfunctions
109
Warning and Malfunction Messages
109
Sender/Receiver Unit Troubleshooting Measures
111
Setting the Laser Alignment
111
MCUDH Ex-3K Control Unit Troubleshooting Measures
113
Replacing the Fuse
113
MCU Control Unit Troubleshooting Measures
114
Replacing the Fuse
114
Sending in Devices
114
Decommissioning
115
Switch-Off States
115
Switching off and Dismantling
115
Return Delivery
116
Disposal
116
Technical Data
117
Dimensional Drawings and Part Numbers
122
DHSP100 Ex-3K Sender/Receiver Unit
122
Flange with Tube
123
MCUDH Ex-3K Control Unit
124
MCU Control Unit
125
Spare Parts
127
Consumable Parts
127
Consumable Parts DUSTHUNTER SP100 Ex-3K
127
Consumable Parts, MCUDH Ex-3K / MCU Control Unit
128
Spare Parts
128
Spare Parts DUSTHUNTER SP100 Ex-3K
128
Spare Parts, Control Unit
128
Accessories
129
Weather Protection Hood
129
Connection Technology
129
Sender/Receiver - Control Unit Cable
129
Fastening Technology
129
Optional Accessories
130
Options for MCUDH Ex-3K Control Unit
130
Other Accessories
130
Options for MCU Control Unit
130
Device Check Accessories
130
Advertisement
Related Products
SICK DUSTHUNTER SP100 Ex-2K
SICK SIM2000
SICK S710 E
SICK S100 Standard
SICK S100 Professional
SICK S10B-9011BA
SICK S10B-9011DA
SICK DUSTHUNTER T
SICK DUSTHUNTER T50
SICK DUSTHUNTER T100
SICK Categories
Accessories
Security Sensors
Measuring Instruments
Scanner
Barcode Reader
More SICK Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL