Sign In
Upload
Manuals
Brands
Seneca Manuals
Data Loggers
Z-LOGGER
Seneca Z-LOGGER Data Loggers Manuals
Manuals and User Guides for Seneca Z-LOGGER Data Loggers. We have
2
Seneca Z-LOGGER Data Loggers manuals available for free PDF download: User Manual
Seneca Z-LOGGER User Manual (186 pages)
Multi-protocol Datalogger/RTU with GSM/GPRS modem and embedded I/O; Multi-protocol Datalogger/RTU with embedded I/O;
Brand:
Seneca
| Category:
Data Loggers
| Size: 4 MB
Table of Contents
Italiano
3
Table of Contents
3
Seneca Z-Gprs2 / Z-Logger
9
1 Informazioni Preliminari
9
2 Caratteristiche
11
3 Specifiche
13
4 Connessioni
16
5 Led DI Segnalazione
18
Led Z-Gprs2
18
Led Z-Logger
19
6 Nozioni DI Base
21
7 Sim Card Supportate (solo Z-Gprs2)
22
8 Segnale Gsm (solo Z-Gprs2)
23
9 La Connessione Gprs (solo Z-Gprs2)
25
10 Coordinate Gps
25
11 Batterie DI Backup
26
Coordinate Gps Via Rete Gprs (solo Z-Gprs2)
26
Acquisizione Dei Dati
27
12 Il Datalogger
27
Invio Dei Dati del Datalogger
27
Orologio Interno
27
Il Logger Modbus Rtu E Modbus Tcp-Ip
28
Log Dell'I/O Embedded
28
File DI Log
30
Gestione Degli Errori del Log Modbus
30
Nome del File DI Log
30
Configurazione del Logger
31
Configurazione Dell'invio Dei Log
32
Configurazione Dei Registri Modbus da Loggare
33
Configurazione del Log Seriale Su Protocollo Modbus Rtu Emodbus Tcp-Ip
33
Campi Configurabili Dei File DI Log
34
Sms DI Log
36
Salvataggio Dei Contatori/Totalizzatori
37
Salvataggio Dei Log Su Microsd Card
37
Tempi DI Invio Via Gprs Dei File DI Log (solo Z-Gprs2)
37
Funzione DI Ridondanza del Canale DI Comunicazione Ethernet/Gprs (solo Z-Gprs2)
38
Gestione Degli Errori DI Connessione Ed Invio Dati Ai Server Ftp E Smtp
38
Contenuto del File "Syslog.csv
39
13 Log DI Sistema (Log Degli Eventi E Degli Allarmi) Su Micro Sd
39
Test Della Configurazione Per L'invio Dei Log Via Ftp
39
Test Della Configurazione Per L'invio Delle E-Mail
39
Contatto "Amministratore
40
Contatto "Operatore
40
Contatto "Utente
40
Invio del File "Syslog.csv
40
14 La Rubrica Contatti E I Gruppi DI Invio
40
Gruppi DI Invio
41
15 Comandi Supportati (solo Z-Gprs2)
42
Elenco Dei Comandi Sms Supportati
42
Impostare L'alfabeto Caratteri Sms del Telefono
42
Comandi Sms "Fast" (solo Z-Gprs2)
46
Password Comandi (solo Z-Gprs2)
49
16 Timer
50
Timer Calendario
50
Timer Periodici
50
Informazioni DI Base Sull'invio Delle E-Mail
52
Server DI Posta in Uscita (Smtp)
52
17 Utilizzo Delle E-Mail
52
Autenticazione Smtp: User Name E Password
53
Connessione Protetta al Server Smtp (solo Z-Gprs2)
53
Parametri Dei Principali Server Smtp Senza Connessione Protetta
54
Parametri Dei Principali Server Smtp con Connessione Protetta Via Gprs (solo Z-Gprs2)
55
Allarme Su Alto E Massimo
56
18 Allarmi Su Ingressi Analogici
56
Filtraggio Degli Ingressi Analogici
56
Allarme Su Basso E Minimo
57
Filtro Per Allarme
57
Tempo DI Inibizione Dell'allarme
58
19 Allarmi Su Ingressi Digitali
59
Filtraggio Sugli Ingressi Digitali
59
Tempo DI Inibizione Dell'allarme
60
20 Allarmi Su Totalizzatori/Contatori
61
Tempo DI Inibizione Dell'allarme
61
21 Allarme Blackout Tensione DI Rete
62
Tempo DI Inibizione Dell'allarme
62
22 Allarme Su Incremento Dei Totalizzatori
63
23 Allarme Su Perdite DI un Impianto
64
26 Allarmi Ausiliari Digitali / Analogici Su Periferiche Modbus Rtu / Modbus Tcp-Ip
66
24 Allarme Su Contaore
66
25 Allarme Su Anomalia Funzionamento Pannelli Solari
66
27 Azione Su Evento
68
Connessione Locale Alla Porta Ethernet
70
28 Funzionalita' Server Via Porta Ethernet
70
Servizio Server Via Porta Ethernet: Web Server
70
Misure Real Time Sul Webserver
73
Comandi Ftp Supportati
77
Ftp Server
77
Modbus Tcp-Ip Server
80
Struttura Dei Registri Modbus Real Time Log
82
29 Accesso a Z-Gprs2 / Z-Logger da Internet (solo Tramite Porta Ethernet)
83
30 Aggiornamento del Firmware
85
Aggiornamento Via Usb (Tramite Software Easy Z-Gprs2/Z- Logger / Easy Setup)
85
Aggiornamento Via Microsd Card (Senza Uso DI Pc)
86
31 Attivare la Porta DI Debug
87
32 Comandi Disponibili Tramite Software DI Configurazione
88
33 Software Easy Setup Ed Easy Z-Gprs2/Z-Logger, Installazione Dei Driver Usb
88
34 Il Kit-Usb
90
35 Soluzione Ai Problemi
91
English
95
Seneca Z-Gprs2 / Z-Logger
100
1 Preliminary Information
100
2 Characteristics
102
3 Specifications
104
4 Connections
107
5 Signal Leds
110
Z-Gprs2 Leds
110
Z-Logger Leds
111
6 Basic Notions
113
7 Supported Sim Cards (Z-Gprs2 Only)
114
8 Gsm Signal (Z-Gprs2 Only)
115
9 Gprs Connection (Zgprs2 Only)
117
10 Gps Coordinates
118
Gps Coordinates Via Gprs Network (Z-Gprs2 Only)
118
11 Backup Batteries
119
Data Acquisition
120
12 Datalogger
120
Internal Clock
120
Sending Datalogger Data
120
Embedded I/O Log
121
Modbus Rtu and Modbus Tcp-Ip Loggers
121
Log File
123
Log File Name
123
Modbus Log Error Management
123
Logger Setup
125
Setting up Log Delivery
125
Serial Log Setup on Modbus Rtu and Modbus Tcp-Ip Protocol
126
Log File Settable Fields
127
Setting Modbus Registers to be Logged
127
Log Sms
129
Log Save on Microsd Card
130
Saving Counters/Totalizers
130
Ftp and Smtp Server Data Connection and Send Error Management
131
Log File Send Time Via Gprs (Z-Gprs2 Only)
131
Configuration Test for Email Send
132
Configuration Test for Log Send Via Ftp
132
Ethernet/Gprs Communication Channel Redundant Function (Z-Gprs2 Only)
132
13 System Log (Event and Alarm Log) on Micro Sd
132
Syslog.csv" File Content
133
Syslog.csv" File Send
133
Administrator" Contact
134
14 Contact Address Book and Delivery Groups
134
Delivery Groups
134
Operator" Contact
134
User" Contact
134
List of Supported Sms Commands
136
Set the Telephone Sms Character Alphabet
136
15 Supported Commands (Z-Gprs2 Only)
136
Fast" Sms Commands (Z-Gprs2 Only)
140
Command Password (Z-Gprs2 Only)
143
Zero Cost" Ring Commands (Z-Gprs2 Only)
143
Calendar Timers
144
Periodic Timers
144
16 Timers
144
Basic Information on Sending Emails
146
17 Email Use
146
Outgoing Mail Server (Smtp)
146
Main Smtp Server Settings Without Protected Connection
147
Smtp Authentication: User Name and Password
147
Smtp Server Protected Connection (Z-Gprs2 Only)
147
Main Smtp Server Parameters with Gprs Protected Connection (Z-Gprs2 Only)
149
Alarm on High and Maximum
150
18 Alarms on Analog Inputs
150
Analog Input Filter
150
Alarm Filter
151
Alarm on Low and Minimum
151
Alarm Inhibition Time
152
19 Alarms on Digital Inputs
153
Digital Input Filter
153
Alarm Inhibition Time
154
Alarm Inhibition Time
155
20 Totalizer/Counter Alarms
155
Alarm Inhibition Time
156
21 Blackout Alarm
156
22 Alarm on Totalizer Increase
157
23 Alarm on Plant Loss
158
24 Hour Counter Alarm
160
25 Alarm on Solar Panel Malfunction
160
26 Auxiliary Digital/Analog Alarms on Modbus Rtu / Modbus Tcp-Ip Peripherals
160
27 Action on Event
161
Local Connection to the Ethernet Port
163
28 Server Function Via Ethernet Port
163
Server Service Via Ethernet Port: Web Server
163
Real Time Readings on Webserver
166
Ftp Server
170
Supported Ftp Commands
170
Modbus Tcp-Ip Server
173
Modbus Real-Time Log Register Format
175
29 Z-Gprs2 / Z-Logger Access Via Internet (Only Via Ethernet Port)
177
30 Firmware Update
179
Update Via Microsd Card (Without Using a Pc)
179
Update Via Usb (Using Easy Z-Gprs2/Z-Logger / Easy Setup Software)
179
31 Debug Port Enable
181
32 Commands Available through the Configuration Software
182
33 Easy Setup Ed Easy Z-Gprs2/Z-Logger Software, Usb Driver Installation
182
34 Usb Kit
184
35 Troubleshooting
185
Advertisement
Seneca Z-LOGGER User Manual (177 pages)
Multi-protocol Datalogger/RTU with GSM/GPRS modem and embedded I/O / Multi-protocol Datalogger/RTU with embedded I/O
Brand:
Seneca
| Category:
Data Loggers
| Size: 4 MB
Table of Contents
Table of Contents
3
Seneca Z-Gprs2 / Z-Logger
11
Preliminary Information
11
1 Characteristics
13
Z-GPRS2 Model Characteristics
13
Z-LOGGER Model Characteristics
14
Technical Specifications
14
Digital Inputs
14
Digital Outputs
15
Analog Inputs
15
Communication Ports
15
Storage Units
16
Power Supply
16
Environmental Conditions
16
Regulations
16
Case Specifications
17
Insulation
17
2 Connections
18
Power Supply Connections
18
Analog Input Connections
18
Auxiliary Voltage Connections
18
Serial Communication RS485 Ports Connections
19
Digital Outputs Connections
20
Digital Inputs Connections
20
3 Signal Leds
21
Z-GPRS2 Leds
21
Z-Logger Leds
22
4 Devices Overview
24
5 Switch On, Switch off and Forced Switch off of Z-Gprs2/Z-Logger
25
6 Supported Sim Cards (Z-Gprs2 Only)
26
7 Gsm Signal (Z-Gprs2 Only)
27
8 Backup Battery
29
9 Usb Driver Installation on Microsoft Windows™ Operating Systems
29
Installing the USB Driver on Windows XP™, Windows Vista™ , Windows 7™, Windows 8™ and Windows 8.1
30
10 Seal (Seneca Advanced Language)
30
SEAL Overview
31
Program Execution in the Graph Panel
32
How SEAL Works
32
11 The Seal Menu Bar
36
Menu File
36
Menu Edit
36
Menu Project Project Settings
37
Groups, Profiles and Users
38
Menu Project: Users
44
Menu Project: User - Add User
45
Menu Project: User Groups
45
Menu RTU: Connection
46
Menu RTU Test Monitor
47
Menu RTU: FW Update
52
Menu RTU: Open Project from RTU
53
Menu RTU: Convert Phonebook CSV
53
Menu Build: Generate
53
Menu Build: Generate and Send to RTU
54
Menu Window: Build Output
55
Menu Window: Edit Form
55
Menu Window: Logs
55
Menu Window: Default Layout
56
Menu Window: Tile Horizontal
56
Menu Window: Tile Vertical
56
Menu Help
56
12 The Seal Icon Menu
56
GSM/GPRS Modem
57
Ethernet Services
59
Real Time Clock
68
Cloud
72
Modbus RTU and Modbus TCP-IP Master Window
76
Data Logger Window
84
Application Window
89
System Management Configuration Window
98
Analog Input Configuration Window
99
Digital Input Configuration Window
102
Digital Input Configuration Window
103
Digital Output Configuration Window
107
13 Event Blocks
108
Event Block SYS_POW_DOWN: System Management Power down
108
Event Block SYS_LOW_BAT: System Management Battery Control
109
Event Block AIN_MAX: Analog Input Maximum Threshold Event
109
Event Block AIN_HIGH: Analog Input High Threshold Event
109
Event Block AIN_LOW: Analog Input Low Threshold Event
109
Event Block AIN_LOW: Analog Input Low Threshold Event
110
Event Block RTC_DAYLIGHT: Daylight Event
110
Event Block RTC_DAWN: Sunrise Event
110
Event Block RTC_DUSK: Sunset Event
110
Event Block RTC_SYNC: Time Synchronization Error Event
111
Event Block DIN_ON: Not Filtered Digital Input on Event
111
Event Block DIN_ALM: Filtered Digital Input Event
111
Event Block DIN_TOT_ALM: Total Counter Event
111
Event Block DIN_CNT_ALM: Partial Counter Event
112
Event Block DIN_WORK_ALM: Work Time Event
112
Event Block DIN_DELTA_ALM: Delta Counter Event
112
Event Block DIN_TOT_RESET: Total Counter Reset Event
112
Event Block DIN_CNT_RESET: Partial Counter Reset Event
113
14 Variable Blocks
113
Variable Block SYS_POW: Main Power Variable
113
Variable Block SYS_VBAT: Main Power Variable
113
Variable Block AIN_VAL : Analog Input Datalogger Sampled Value
114
Variable Block AIN_AVG : Analog Input Datalogger Average Value
114
Variable Block AIN_MIN : Analog Input Datalogger Minimum Value
114
Variable Block AIN_MAX : Analog Input Datalogger Maximum Value
115
Variable Block DIN_STS: Digital Input Value Sampled Variable
115
Variable Block DIN_TOT: Total Counter Value Sampled Variable
116
Variable Block DIN_CNT: Partial Counter Value Sampled Variable
116
Variable Block DOUT_STS: Digital Output Value Sampled Variable
116
Variable Block GSM_DBM: GSM Signal Field Value Sampled Variable
117
Variable Block MODBUS IN/OUT: Modbus Value Variable
117
15 Blocks Functions
118
Function Block BIT: STATE BITS TEST FUNCTION
118
Function Block BIT_AND: and REGISTERS STATE BITS TEST FUNCTION
119
Function Block BIT_AND: or REGISTERS STATE BITS TEST FUNCTION
121
Function Block CMP: ANALOG DIFFERENCE COMPARE FUNCTION
122
Function Block THR: ANALOG THRESHOLD COMPARE with HYSTERESIS FUNCTION
123
Function Block CPY: ANALOG VARIABLE COPY to ANOTHER VARIABLE with TRIGGER FUNCTION
124
Function Block LST: SCALED ANALOG INPUTS LESS than COMPARE FUNCTION
125
Function Block GRT: SCALED ANALOG INPUTS GREATER than COMPARE FUNCTION
126
Function Block POW: ANALOG INPUTS MULTIPLICATION GREATER than COMPARE FUNCTION
127
Function Block AVG: ANALOG AVERAGE GREATER than COMPARE FUNCTION
128
Function Block DEV: ANALOG AVERAGE ABSOLUTE DIFFERENCE GREATER than COMPARE FUNCTION
129
Function Block MAD: ANALOG AVERAGE ABSOLUTE DIFFERENCE COMPARE with CHANNEL DETECT
130
Function
130
16 Blocks Controls
132
Control Block EC: EVENT LOGIC CONTROL
132
Control Block EC Setup Configuration
135
Control Block MSG: Event Notify Message
138
Control Block CAL: Calendar Block Control
139
Control Block TRG: Timed Trigger Block Control
141
Control Block TMR: Timer Control Block Control
143
17 Blocks Actions Douts
146
Action Block DOUTS RESET: Reset Digitals Output 1 and Output 2 Action
146
Action Block DOUTS SET: Set Digitals Output 1 and Output 2 Action
147
Action Block DOUTS TOGGLE: Toggle Digitals Output 1 and Output 2 Action
147
Action Block DOUTS RES1_SET2: Reset Digital Output 1 and Set Digital Output 2 Action
148
Action Block DOUTS SET1_RES2: Set Digital Output 1 and Reset Digital Output 2 Action
148
Action Block DOUT RESET: Reset Digital Output Action
149
Action Block DOUT SET: Set Digital Output Action
149
Action Block DOUT TOGGLE: Toggle Digital Output Action
150
Action Block PULSE_RESET: Pulse Reset Output Action
150
Action Block PULSE_SET: Pulse Set Output Action
151
Action Block PULSE_TOGGLE: Pulse Toggle Output Action
151
18 Blocks Actions Modbus
152
Action Block BIT_CLR: Modbus Register Bit Clear Action
152
Action Block BIT_SET: Modbus Register Bit Set Action
152
Action Block DEC: Modbus Register Decrement Action
153
Action Block INC: Modbus Register Increment Action
153
Action Block RES: Modbus Register Reset Action
154
Action Block COPY: Modbus Register Copy Action
154
19 Local Firmware Update
154
Firmware Update Via USB
155
Firmware Update Via Microsd Card (Without Using a PC)
155
20 Remote Firmware Update
156
Remote Firmware Update by Ethernet Connection (FTP Server Activated)
156
Remote Firmware Update by Ethernet Connection (Modbus TCP-IP Server Activated)
156
Remote Firmware Update by GPRS Connection
157
21 Local Configuration Update
159
Local Configuration Update by SD Card
159
22 Remote Configuration Update
159
Remote Configuration Update by Ethernet Connection (FTP Server Enabled)
159
Remote Configuration Update by Ethernet Connection (Modbus TCP-IP Server Enabled)
160
Remote Configuration Update by GPRS Connection
161
23 Extended Phonebook into Microsd for Ring Command
162
Creation of an Extended Phonebook File
162
Update of an Extended Phonebook File Via Ethernet
163
Update of an Extended Phonebook File Via Gprs
163
24 Supported Sms Commands (Only Z-Gprs2)
163
Set the Telephone Sms Character Alphabet
163
List of Supported Sms Commands
164
25 Supported Modbus Tcp-Ip Commands (Only by Ethernet)
169
26 Seal Program Examples
170
Send Alert SMS on Digital Input 1 and Copy Alert State on Output 1
170
Temperature Control with Logger and Alerts
172
Remote Inputs to Remote Outputs Copy by Ethernet Connection
174
Advertisement
Related Products
Seneca Z-LOGGER3
Seneca Z-LOGGER-SEAL
Seneca Z-UMTS
Seneca Z-GPRS3
Seneca Z-GPRS2-SEAL
Seneca Z-LTE
Seneca Z-GPRS2
Seneca Z-8R-10A
Seneca Z-LTE-WW
Seneca Z-LINK2-LO
Seneca Categories
Media Converter
Gateway
Control Unit
I/O Systems
Measuring Instruments
More Seneca Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL