SCIEX 5500 Series Mass Spectrometer Manuals
Manuals and User Guides for SCIEX 5500 Series Mass Spectrometer. We have
1
SCIEX 5500 Series Mass Spectrometer manual available for free PDF download: System User's Manual
SCIEX 5500 Series System User's Manual (195 pages)
Brand:
SCIEX
| Category:
Laboratory Equipment
| Size: 3 MB
Table of Contents
Table of Contents
3
Chapter 1 Operational Precautions and Limitations
8
General Safety Information
8
Regulatory Compliance
8
Australia and New Zealand
8
Canada
9
Europe
9
United States
9
International
10
Electrical Precautions
10
AC Mains Supply
10
Protective Earth Conductor
11
Chemical Precautions
11
System Safe Fluids
12
Ventilation Precautions
13
Environmental Precautions
14
Electromagnetic Environment
14
Decommissioning and Disposal
15
Qualified Personnel
16
Laboratory Conditions
16
Operating Conditions
16
Performance Specifications
16
Equipment Use and Modification
17
Contact Us
17
Technical Support
18
Documentation Symbols and Conventions
18
Related Documentation
19
Chapter 2 Principles of Operation
20
System Overview
20
Hardware Overview
21
Theory of Operation-Hardware
24
Analyst Software Overview
26
Theory of Operation-Analyst Software
33
Chapter 3 Operating Instructions Sample Workflows
36
Chapter 4 Operating Instructions Hardware
45
Start up the System
45
Reset the Mass Spectrometer
46
Shut down and Vent the System
46
Adjust the Integrated Syringe Pump Position
47
Plumb the Diverter Valve
51
Plumb the Diverter Valve in Injector Mode
52
Plumb the Diverter Valve in Diverter Mode
53
Chapter 5 Operating Instructions Hardware Profiles and Projects
55
Hardware Profiles
55
Create a Hardware Profile
55
Add Devices to a Hardware Profile
59
Troubleshoot Hardware Profile Activation
61
Projects and Subprojects
62
Create Projects and Subprojects
62
Create Subprojects
63
Copy Subprojects
63
Switch between Projects and Subprojects
64
Installed Project Folders
64
Back up the API Instrument Folder
65
Recover the API Instrument Folder
65
Chapter 6 Tune and Calibrate
66
Verify Instrument Performance
66
About the Verifying or Adjusting Performance Dialog
67
Results Summary
67
Chapter 7 Automatic Optimization
69
About Automatic Optimization
70
Types of Sample Introduction
70
Automatically Optimize for an Analyte Using Infusion
71
Confirm the Presence of Compounds
71
Perform Automatic MS and MS/MS Optimization Using Infusion with a Known Precursor Ion and an Unknown Product Ion
73
Review the Optimization Results
76
Automatically Optimize for an Analyte Using FIA
77
Chapter 8 Operating Instructions Acquisition Methods
84
Create an Acquisition Method Using the Acquisition Method Editor
84
Configure the Integrated Syringe Pump
85
Add an Experiment
85
Add a Period
86
Copy an Experiment into a Period
86
Copy an Experiment Within a Period
86
Scan Techniques
87
Quadrupole-Mode Scan Types
87
LIT-Mode Scan Types
88
About Spectral Data Acquisition
89
Chapter 9 Operating Instructions Analyze and Process Quantitative Data
90
Quantitative Analysis
90
Quantitation Methods
90
About Results Tables
91
Quantitation Methods and Results Tables
91
Create a Method Using the Quantitation Method Editor
91
Create a Results Table Using the Quantitation Wizard
93
Create a Standard Query (Optional)
94
Results Table Right-Click Menu
97
Peak Review and Manual Integration of Peaks
98
Review Peaks
98
Manually Integrate Peaks
103
Peak Review Right-Click Menu
104
Calibration Curves
105
View Calibration Curves
105
Overlay Calibration Curves
107
Calibration Curve Right-Click Menu
107
Sample Statistics
108
View the Statistics for Standards and Qcs
108
Compare Results between Batches
109
Chapter 10 Operating Instructions Analyze and Explore Data
110
Open Data Files
110
Navigate between Samples in a Data File
110
View Experimental Conditions
111
Show Data in Tables
112
Show ADC Data
114
Show Basic Quantitative Data
115
Chromatograms
116
Show Tics from a Spectrum
117
Show a Spectrum from a TIC
117
About Generating Xics
118
Generate an XIC Using a Selected Range
119
Generate an XIC Using the Maximum Peak
119
Generate an XIC Using Base Peak Masses
120
Extract Ion by Selecting Masses
120
Generate Bpcs
121
Generate Xwcs
123
Generate DAD Data
123
Generate Twcs
124
Adjust the Threshold
124
Chromatogram Panes
125
Spectra Panes
126
Graphical Data Processing
126
Graphs
127
Manage Data
127
Zoom in on the Y-Axis
129
Zoom in on the X-Axis
129
Chapter 11 Reporter Software
130
Analyst Reporter User Interface
131
Generate Reports
133
Chapter 12 Operating Instructions Batches
135
Set Queue Options
135
Create and Submit a Batch
136
Add Sets and Samples to a Batch
136
Equilibrate the System
139
Submit a Sample or Set of Samples
140
Change Sample Order
140
Acquire Data
140
Set Sample Locations in the Batch Editor
141
Select Vial Positions Using the Locations Tab (Optional)
142
Set Quantitation Details in the Batch Editor (Optional)
143
Stop Sample Acquisition
143
Import Batch Files
144
Build a Batch as a Text File
144
Import a Batch from a Text File
144
Batch Editor Right-Click Menu
145
Queue States and Device Status
146
Queue States
146
View Instrument and Device Status Icons
147
Queue Right-Click Menu
148
Chapter 13 Service and Maintenance Information
150
Recommended Maintenance Schedule
150
Clean the Surfaces
152
Clean the Front-End
152
Symptoms of Contamination
153
Required Materials
153
Cleaning Best Practices
154
Prepare the Mass Spectrometer
155
Clean the Curtain Plate
156
Clean the Front of the Orifice Plate
157
Put the Mass Spectrometer Back in Service
157
Inspect the Roughing Pump Oil Level
158
Empty the Source Exhaust Drain Bottle
158
Storage and Handling
160
Chapter 14 Mass Spectrometer Troubleshooting
161
Appendix A Operating Instructions Manual Compound Optimization
164
About Manual Compound Optimization
164
About Scan Types
165
Manually Optimize an Analyte
165
Confirm the Presence of Compounds
165
Optimize MS-Specific Parameters
167
Determine the Product Ions for Optimization
168
Optimize Collision Cell Exit Potential for each Product Ion
170
Manually Optimize the Ion Source and Gas Parameters
171
Prepare the Ion Source
171
Optimize the Ion Source Parameters
171
Advanced Parameters
172
Optimize AF2
172
About Collision Energy Spread (CES)
173
Appendix B 5500 Series System Parameters
174
Appendix C Calibration Ions and Solutions
177
Appendix D Toolbar Icons
180
Appendix E Glossary of Symbols
189
Appendix F Glossary of Warnings
194
Advertisement
Advertisement
Related Products
SCIEX TripleTOF 5600 Plus
SCIEX TripleTOF 5600
SCIEX 3200 QTRAP
SCIEX 3200 Series
Sciex 6500 series
Sciex 6500+ series
SCIEX 6500PLUS Series
SCIEX API 3200
SCIEX C100HT
Sciex NanoSpray
SCIEX Categories
Laboratory Equipment
Portable Generator
Medical Equipment
Control Unit
Analytical Instruments
More SCIEX Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL