Sign In
Upload
Manuals
Brands
RKI Instruments Manuals
Measuring Instruments
GX-3R
RKI Instruments GX-3R Manuals
Manuals and User Guides for RKI Instruments GX-3R. We have
6
RKI Instruments GX-3R manuals available for free PDF download: Operator's Manual, Quick Reference Manual
RKI Instruments GX-3R Operator's Manual (128 pages)
Brand:
RKI Instruments
| Category:
Measuring Instruments
| Size: 1 MB
Table of Contents
Table of Contents
3
Chapter 1: Introduction
7
Overview
7
About the GX-3R
7
Specifications
8
About this Manual
10
Chapter 2: Description
11
Overview
11
Instrument Description
11
Case
11
Lcd
11
Control Buttons
12
Alarm Leds
12
Buzzer
12
Vibrator
12
Sensors
13
Filters
13
Infrared Communications Port
14
Charging Socket and Battery Pack
14
Included Accessories
15
Alligator Clip
15
Rubber Boot
15
Wrist Strap
15
Single-Unit AC Charger
16
Calibration Cup
16
Other Accessories
16
12 VDC Charger
16
Multi-Unit AC Charger
16
Belt Clip
17
Sdm-3R
17
Aspirator Adapter
17
Irda Cable
17
Chapter 3: Operation
18
Overview
18
Start up
18
Turning on the GX-3R
18
Performing a Demand Zero
24
Turning off the GX-3R
24
Measuring Mode Operation
25
Monitoring an Area
25
Combustible Gas Detection
26
Oxygen-Enriched Atmospheres
27
H 2 -Compensated CO Detection
27
Interference Information
28
Aspirator Adapter Sampling
28
Alarms
29
Alarm Indications
29
Responding to Alarms
31
Data Logging
35
Chapter 4: Display Mode
36
Tips for Using Display Mode
37
Peak Screen (PEAK)
37
STEL Screen (STEL)
38
TWA Screen (TWA)
38
Combustible Sensor Target Gas Conversion (LIST)
38
Changing the User ID (USER ID)
40
Changing the Station ID (STN ID)
41
Last Successful Calibration Date (CAL DATA)
42
Last Successful Bump Test Date (BUMP DATA)
43
Date, Time, and Temperature Screen (TEMP)
43
Viewing Alarm Settings Screen (ALARM--PT)
44
Chapter 5: User Mode and Calibration
45
Overview
45
Entering User Mode
48
Tips for Using User Mode
49
Performing a Bump Test (BUMP)
49
Performing a Calibration (GAS CAL)
56
Setting Calibration Parameters (CAL SET)
66
Setting Bump Test Parameters (BUMP SET)
68
Alarm Settings (ALARM--PT)
72
Updating the Lunch Break Setting (LUNCH)
74
Setting the Confirmation Beep and Non-Compliance Indicator (BEEP)
75
Updating the Backlight Time (BL TIME)
77
Turning the Key Tone On/Off (KEY TONE)
77
Display Mode Items (DISP SET)
78
Zero Suppression (ZERO SUP)
78
Zero Follower (ZERO.FLWR)
78
Setting the Date/Time (DATE)
79
Turning the Password On/Off (PASSWORD)
79
Viewing the ROM/SUM (ROM/SUM)
80
Entering Measuring Mode (START)
81
Chapter 6: Maintenance
82
Overview
82
Troubleshooting
82
Instrument Cleaning
83
Recharging the Batteries
83
Replacing the Buzzer Cover
85
Replacing the Sensor Filters
85
Replacing the Hydrophobic Dust Filter
87
Replacing a Sensor
88
Replacing the Battery Board
90
Chapter 7: Storage
93
Chapter 8: General Parts List
94
Appendix A: Maintenance Mode
96
Overview
96
Entering Maintenance Mode
98
Tips for Using Maintenance Mode
99
Performing a Calibration (GAS CAL)
99
Performing a Gas Test (GAS TEST)
99
Sensor/Battery Replacement Date (SEN DATE)
101
Performing a Bump Test (BUMP)
102
Setting Alarms to Latching or Self-Resetting (LATCHING)
103
Turning the Demand Zero Function On/Off (dem ZERO)
103
Turning the Auto Zero Function On/Off (AUTOZERO)
104
Turning the ID Display Function On/Off (ID DISP)
104
Turning the Zero Suppression On/Off (ZERO SUP)
105
Turning the Zero Follower On/Off (ZERO.FLWR)
105
User Mode Zero Suppression (ZSUP.DISP)
105
User Mode Zero Follower (ZFLW.DISP)
105
Setting the Date/Time (DATE)
105
Turning the Password On/Off (PASSWORD)
106
Viewing the ROM/SUM (ROM/SUM)
107
Performing a Default (M.DEFAULT)
107
Entering Measuring Mode (START)
108
Appendix B: Gas Select Mode
109
Overview
109
Entering Gas Select Mode
110
Tips for Using Gas Select Mode
110
Changing the Gas Combination (GAS COMB)
111
Saving the Alarm Points (SAVE-AP)
114
Turning Calibration Max Span On/Off (MAX SPAN)
114
Stealth and Vibrator Settings (STEALTH)
115
LEL Definition (CHG LEL)
116
Exiting Gas Select Mode (START)
117
Appendix C: Interference Information
118
ESR-A13I-H2S, H S Detection
118
ESR-A13P-CO, CO Detection
120
ESR-A1CP-COH, H 2 -Compensated CO Detection
122
ESR-A1DP-COHS, CO Detection
124
ESR-A1DP-COHS, H 2 S Detection
126
Advertisement
RKI Instruments GX-3R Operator's Manual (122 pages)
Brand:
RKI Instruments
| Category:
Measuring Instruments
| Size: 0 MB
Table of Contents
Table of Contents
3
Chapter 1: Introduction
7
Overview
7
About the GX-3R
7
Specifications
8
About this Manual
10
Chapter 2: Description
11
Overview
11
Instrument Description
11
Case
11
Lcd
11
Control Buttons
12
Alarm Leds
12
Buzzer
12
Vibrator
12
Sensors
12
Filters
13
Infrared Communications Port
14
Charging Socket and Battery Pack
14
Included Accessories
15
Alligator Clip
15
Rubber Boot
15
Wrist Strap
15
Single-Unit AC Charger
15
Calibration Cup
16
Other Accessories
16
12 VDC Charger
16
Multi-Unit AC Charger
16
Belt Clip
16
Sdm-3R
16
Irda Cable
17
Rp-3R
17
Chapter 3: Operation
18
Overview
18
Start up
18
Turning on the GX-3R
18
Performing a Demand Zero
23
Turning off the GX-3R
23
Measuring Mode Operation
24
Monitoring an Area
24
Combustible Gas Detection
25
Oxygen-Enriched Atmospheres
26
H 2 -Compensated CO Detection
26
Interference Information
26
Alarms
27
Alarm Indications
27
Responding to Alarms
29
Data Logging
32
Chapter 4: Display Mode
33
Tips for Using Display Mode
34
Peak Screen (PEAK)
34
STEL Screen (STEL)
35
TWA Screen (TWA)
35
Combustible Sensor Target Gas Conversion (LIST)
35
Changing the User ID (USER ID)
37
Changing the Station ID (STN ID)
38
Last Successful Calibration Date (CAL DATA)
39
Last Successful Bump Test Date (BUMP DATA)
40
Date, Time, and Temperature Screen (TEMP)
40
Viewing Alarm Settings Screen (ALARM--PT)
41
Chapter 5: User Mode and Calibration
42
Overview
42
Entering User Mode
45
Tips for Using User Mode
46
Performing a Bump Test (BUMP)
46
Performing a Calibration (GAS CAL)
52
Setting Calibration Parameters (CAL SET)
62
Setting Bump Test Parameters (BUMP SET)
64
Alarm Settings (ALARM--PT)
68
Updating the Lunch Break Setting (LUNCH)
71
Setting the Confirmation Beep and Non-Compliance Indicator (BEEP)
72
Updating the Backlight Time (BL TIME)
74
Turning the Key Tone On/Off (KEY TONE)
74
Display Mode Items (DISP SET)
75
Zero Suppression (ZERO SUP)
75
Zero Follower (ZERO.FLWR)
75
Setting the Date/Time (DATE)
76
Turning the Password On/Off (PASSWORD)
76
Viewing the ROM/SUM (ROM/SUM)
77
Entering Measuring Mode (START)
78
Chapter 6: Maintenance
79
Overview
79
Troubleshooting
79
Instrument Cleaning
80
Recharging the Batteries
80
Replacing the Buzzer Cover
81
Replacing the Sensor Filters
82
Replacing the Hydrophobic Dust Filter
84
Replacing a Sensor
85
Chapter 7: Storage
87
Chapter 8: General Parts List
88
Appendix A: Maintenance Mode
90
Overview
90
Entering Maintenance Mode
92
Tips for Using Maintenance Mode
93
Performing a Calibration (GAS CAL)
93
Performing a Gas Test (GAS TEST)
93
Sensor/Battery Replacement Date (SEN DATE)
95
Performing a Bump Test (BUMP)
96
Setting Alarms to Latching or Self-Resetting (LATCHING)
97
Turning the Demand Zero Function On/Off (dem ZERO)
97
Turning the Auto Zero Function On/Off (AUTOZERO)
98
Turning the ID Display Function On/Off (ID DISP)
98
Turning the Zero Suppression On/Off (ZERO SUP)
99
Turning the Zero Follower On/Off (ZERO.FLWR)
99
User Mode Zero Suppression (ZSUP.DISP)
99
User Mode Zero Follower (ZFLW.DISP)
99
Setting the Date/Time (DATE)
99
Turning the Password On/Off (PASSWORD)
100
Viewing the ROM/SUM (ROM/SUM)
101
Performing a Default (M.DEFAULT)
101
Entering Measuring Mode (START)
102
Appendix B: Gas Select Mode
103
Overview
103
Entering Gas Select Mode
104
Tips for Using Gas Select Mode
104
Changing the Gas Combination (GAS COMB)
105
Saving the Alarm Points (SAVE-AP)
107
Turning Calibration Max Span On/Off (MAX SPAN)
108
Stealth and Vibrator Settings (STEALTH)
109
LEL Definition (CHG LEL)
109
Exiting Gas Select Mode (START)
111
Appendix C: Interference Information
112
ESR-A13I-H2S, H S Detection
112
ESR-A13P-CO, CO Detection
114
ESR-A1CP-COH, H -Compensated CO Detection
116
ESR-A1DP-COHS, CO Detection
118
ESR-A1DP-COHS, H 2 S Detection
120
RKI Instruments GX-3R Operator's Manual (106 pages)
gas monitor
Brand:
RKI Instruments
| Category:
Measuring Instruments
| Size: 0 MB
Table of Contents
Table of Contents
3
Chapter 1: Introduction
6
Overview
6
About the GX-3R
6
Specifications
7
About this Manual
8
Chapter 2: Description
9
Overview
9
Instrument Description
9
Case
9
Lcd
9
Control Buttons
10
Alarm Leds
10
Buzzer
10
Vibrator
10
Sensors
10
Filters
11
Infrared Communications Port
12
Charging Socket and Battery Pack
12
Included Accessories
13
Alligator Clip
13
Rubber Boot
13
Wrist Strap
13
Single-Unit Charging Cable
13
Calibration Cup
14
Other Accessories
14
Multi-Unit Charger
14
Belt Clip
14
Sdm-3R
14
Irda Cable
14
Chapter 3: Measuring Mode
15
Overview
15
Start up
15
Turning on the GX-3R
15
Performing a Demand Zero
20
Turning off the GX-3R
20
Measuring Mode Operation
21
Monitoring an Area
21
Combustible Gas Detection
22
Alarms
23
Alarm Indications
23
Responding to Alarms
25
Data Logging
27
Chapter 4: Display Mode
29
Tips for Using Display Mode
30
Peak Screen (PEAK)
30
STEL Screen (STEL)
31
TWA Screen (TWA)
31
Changing the Combustible Gas Sensor's Gas (LIST)
32
Changing the User ID (USER ID)
33
Changing the Station ID (STN ID)
34
Last Successful Calibration Date (CAL DATA)
35
Last Successful Bump Test Date (BUMP DATA)
36
Date, Time, and Temperature Screen (TEMP)
37
Viewing Alarm Settings Screen (ALARM--PT)
37
Chapter 5: User Mode and Calibration
39
Overview
39
Entering User Mode
42
Tips for Using User Mode
43
Performing a Bump Test (BUMP)
43
Performing a Calibration (GAS CAL)
47
Setting Calibration Parameters (CAL SET)
56
Setting Bump Test Parameters (BUMP SET)
58
Alarm Settings (ALARM--PT)
62
Updating the Lunch Break Setting (LUNCH)
65
Setting the Confirmation Beep and Non-Compliance Indicator (BEEP)
66
Updating the Backlight Time (BL TIME)
68
Turning the Key Tone On/Off (KEY TONE)
68
Display Mode Items (DISP SET)
69
Zero Suppression (ZERO SUP)
69
Zero Follower (ZERO.FLWR)
69
Setting the Date/Time (DATE)
70
Turning the Password On/Off (PASSWORD)
70
Viewing the ROM/SUM (ROM/SUM)
71
Entering Measuring Mode (START)
72
Chapter 6: Maintenance
73
Overview
73
Troubleshooting
73
Recharging the Batteries
74
Replacing the Buzzer Cover
75
Replacing the Filters
75
Replacing the Hydrophobic Dust Filter
77
Replacing a Sensor
78
Chapter 7: General Parts List
80
Appendix A: Maintenance Mode
82
Overview
82
Entering Maintenance Mode
83
Tips for Using Maintenance Mode
84
Performing a Calibration (GAS CAL)
85
Performing a Gas Test (GAS TEST)
85
Sensor/Battery Replacement Date (SEN DATE)
87
Performing a Bump Test (BUMP)
88
Setting Alarms to Latching or Self-Resetting (LATCHING)
89
Turning the Demand Zero Function On/Off (dem ZERO)
89
Turning the Auto Zero Function On/Off (AUTOZERO)
90
Turning the ID Display Function On/Off (ID DISP)
90
Turning the Zero Suppression On/Off (ZERO SUP)
91
Turning the Zero Follower On/Off (ZERO.FLWR)
91
User Mode Zero Suppression (ZSUP.DISP)
91
User Mode Zero Follower (ZFLW.DISP)
91
Setting the Date/Time (DATE)
91
Turning the Password On/Off (PASSWORD)
92
Viewing the ROM/SUM (ROM/SUM)
93
Performing a Default (M.DEFAULT)
94
Entering Measuring Mode (START)
95
Appendix B: Gas Select Mode
96
Overview
96
Entering Gas Select Mode
97
Tips for Using Gas Select Mode
97
Changing the Gas Combination (GAS COMB)
98
Saving the Alarm Points (SET R AP)
100
Turning Calibration Max Span On/Off (MAX SPAN)
102
Stealth and Vibrator Settings (STEALTH)
102
LEL Definition (CHG LEL)
103
Exiting Gas Select Mode (START)
105
Advertisement
RKI Instruments GX-3R Operator's Manual (102 pages)
Brand:
RKI Instruments
| Category:
Gas Detectors
| Size: 0 MB
Table of Contents
Table of Contents
3
Chapter 1: Introduction
6
Overview
6
About the GX-3R
6
Specifications
7
About this Manual
9
Chapter 2: Description
10
Overview
10
Instrument Description
10
Included Accessories
14
Other Accessories
15
Chapter 3: Operation
17
Overview
17
Start up
17
Turning on the GX-3R
17
Performing a Demand Zero
23
Turning off the GX-3R
24
Measuring Mode Operation
25
Monitoring an Area
25
Combustible Gas Detection
26
Oxygen-Enriched Atmospheres
27
H 2 -Compensated CO Detection
27
Interference Information
27
Aspirator Adapter Sampling
28
Alarms
29
Alarm Indications
29
Responding to Alarms
31
Data Logging
36
Chapter 4: Display Mode
37
Tips for Using Display Mode
38
Peak Screen (PEAK)
38
STEL Screen (STEL)
39
TWA Screen (TWA)
39
Combustible Sensor Target Gas Conversion (LIST)
39
Changing the User ID (USER ID)
42
Changing the Station ID (STN ID)
43
Last Successful Calibration Date (CAL DATA)
43
Last Successful Bump Test Date (BUMP DATA)
44
Date, Time, and Temperature Screen (TEMP)
45
Viewing Alarm Settings Screen (ALARM--PT)
45
Chapter 5: User Mode and Calibration
47
Overview
47
Entering User Mode
50
Tips for Using User Mode
51
Performing a Bump Test (BUMP)
51
Performing a Calibration (GAS CAL)
58
Chapter 6: Maintenance
71
Overview
71
Troubleshooting
71
Instrument Cleaning
72
Recharging the Batteries
73
Replacing the Buzzer Cover
74
Replacing the Sensor Filters
75
Replacing the Hydrophobic Dust Filter
77
Replacing a Sensor
78
Replacing the Battery Board
80
Chapter 7: Storage
84
Chapter 8: General Parts List
85
Appendix A: Maintenance Mode
88
Overview
88
Entering Maintenance Mode
90
Tips for Using Maintenance Mode
91
Appendix B: Gas Select Mode
92
Overview
92
Entering Gas Select Mode
92
Tips for Using Gas Select Mode
93
Appendix C: Interference Information
94
ESR-A13I-H2S, H S Detection
94
ESR-A13P-CO, CO Detection
95
ESR-A1CP-COH, H 2 -Compensated CO Detection
97
ESR-A1DP-COHS, CO Detection
98
Esr-A1Dp-Cohs, H
100
RKI Instruments GX-3R Quick Reference Manual (52 pages)
Brand:
RKI Instruments
| Category:
Gas Detectors
| Size: 18 MB
Table of Contents
Normal Operation
5
Fresh Air
5
Display Mode
10
User Mode
12
Maintenance Mode
15
Maintenance
24
Sensor Replacement
26
Control Buttons
38
Start-Up Procedure
39
Display Mode
42
RKI Instruments GX-3R Operator's Manual (12 pages)
Pump for GX-3R and GX-3R Pro
Brand:
RKI Instruments
| Category:
Water Pump
| Size: 0 MB
Table of Contents
Product Warranty
2
Table of Contents
3
Overview
4
Specifications
4
Description
5
Pump Unit
5
Rubber Sample Nipple
6
Optional Hose & Probe
6
Normal Operation
6
Switching Flow Rates
10
Alarms
10
Maintenance
11
Replacing the Battery
11
Replacing the Hydrophobic Disk Filter and Wire Mesh Disk
11
Parts List
12
Advertisement
Related Products
RKI Instruments GX-2003
RKI Instruments GX-8000
RKI Instruments GP-03
RKI Instruments GX-2001
RKI Instruments GD-K77D
RKI Instruments GD-K77D-NT
RKI Instruments GD-70D4 Series
RKI Instruments GX-Force
RKI Instruments GX-3R Pro
RKI Instruments GX-86A
RKI Instruments Categories
Transmitter
Security Sensors
Gas Detectors
Measuring Instruments
Monitor
More RKI Instruments Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL