Sign In
Upload
Manuals
Brands
Riello Manuals
Burner
S023
User Manuals: Riello S023 Compact Gas Burner
Manuals and User Guides for Riello S023 Compact Gas Burner. We have
1
Riello S023 Compact Gas Burner manual available for free PDF download: Installation, Use And Maintenance Instructions
Riello S023 Installation, Use And Maintenance Instructions (88 pages)
Premix gas burners, Progressive two-stage or modulating operation with pilot flame ignition
Brand:
Riello
| Category:
Burner
| Size: 7.51 MB
Table of Contents
Table of Contents
3
1 Declarations
5
2 Information and General Warnings
7
Information about the Instruction Manual
7
Introduction
7
General Dangers
7
Other Symbols
7
Delivery of the System and the Instruction Manual
8
Guarantee and Responsibility
8
3 Safety and Prevention
9
Introduction
9
Personnel Training
9
4 Technical Description of the Burner
10
Models Available
10
Burner Categories - Countries of Destination
10
Technical Data
10
Electrical Data
11
Burner Weight
11
Maximum Dimensions
12
Burner Description
13
Electrical Panel Description
14
Burner Equipment
14
Firing Rates
15
Commercial Boilers
16
Test Boiler
16
Control Box for the Air/Fuel Ratio (REC 27
17
Operation Sequence of the Burner
19
List of Phases
20
Operator Panel Operation
20
Description of the Symbols on the Display
20
Description of the Buttons
21
Servomotor (SQM33
22
Calibration of the Thermal Relay
23
5 Installation
24
Notes on Safety for the Installation
24
Handling
24
Preliminary Checks
24
Operating Position
25
Preparing the Boiler
25
Boring the Boiler Plate
25
Blast Tube Length
25
Securing the Burner to the Boiler
26
Access to Head Internal Part
27
Filter Accessibility (Accessory)
27
Position of Electrode - Flame Sensor
28
Gas Butterfly Valve
28
Gas Line
29
Gas Train
30
Gas Train Installation
30
Gas Pressure
30
Electrical Wiring
32
Supply Cables and External Connections Passage
33
6 Start-Up, Calibration and Operation of the Burner
34
Notes on Safety for the First Start-Up
34
Adjustments Prior to Ignition
34
Burner Start-Up
34
Burner Adjustment
35
Ignition Pilot Adjustment
35
Air / Fuel Adjustment
35
Air Adjustment for Maximum Output
35
Air/Fuel Adjustment and Output Modulation System
35
Final Adjustment of the Pressure Switches
36
Air Pressure Switch
36
Maximum Gas Pressure Switch
36
Minimum Gas Pressure Switch
37
Pressure Switch for the Leak Detection Control
37
Air Pressure Switches with Intake Filter
37
Visualisation and Programming Mode
38
Normal Mode
38
Info Mode
39
Service Mode
40
Parameters Mode
40
Parameter Modification Procedure
41
Start-Up Procedure
43
Backup / Restore Procedure
45
Backup
45
Restore
46
List of Parameters
47
Operation
51
Motor Lockout
51
Ignition Failure
51
Burner Flame Goes out During Operation
51
Stopping of the Burner
52
Final Checks (with Burner Operating)
52
Monitoring System of the Combustion Head Temperature
52
7 Maintenance
53
Notes on Safety for the Maintenance
53
Maintenance Programme
53
Maintenance Frequency
53
Safety Test - with Gas Feeding Closed
53
Checking and Cleaning
53
Electrical Current to Flame Sensor
54
Measuring the Flame Signal
54
Flame Sensor
55
Checking the Gas Pressure on the Combustion Head
55
Safety Components
56
Opening the Burner
56
Closing the Burner
56
8 Faults - Probable Causes - Solutions
57
List of Error Codes
57
A Appendix - Accessories
64
B Appendix - Electrical Panel Layout
65
Advertisement
Advertisement
Related Products
Riello S024
Riello S025
Riello S022
Riello S045T2
Riello S046T2
Riello S032T
Riello S048T2
Riello S044T2
Riello S041T2
Riello S043T1
Riello Categories
Burner
Boiler
Indoor Fireplace
UPS
Water Heater
More Riello Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL