Sign In
Upload
Manuals
Brands
Reznor Manuals
Furnace
RPB
User Manuals: Reznor RPB Outdoor Packaged Unit
Manuals and User Guides for Reznor RPB Outdoor Packaged Unit. We have
4
Reznor RPB Outdoor Packaged Unit manuals available for free PDF download: Installation, Operation And Maintenance Manual, Manual, Quick Start Manual, Installation
Reznor RPB Installation, Operation And Maintenance Manual (48 pages)
OUTDOOR PACKAGED DUCT FURNACE AND BLOWER
Brand:
Reznor
| Category:
Furnace
| Size: 4 MB
Table of Contents
Table of Contents
2
General Information
3
References
3
Important Safety Information
4
Warranty
4
Installation Codes
5
Dimensions
5
Weights
6
Clearances
6
Location
6
Hazards of Chlorine
7
Combustion Air Requirements
7
Curb Cap Base
7
Installation
7
Uncrating/Unpacking
7
Shipped-Separate Parts
7
Mounting Support Structure
8
Bottom Duct Connections
8
Optional Curb (Option CJ1 or CJ2) Assembly
9
Field-Supplied Support Structure
11
Mounting
12
Duct Connections
12
Requirements and Suggestions for Connecting and Installing Ducts
12
100% Outside Air Hood (Option AS2)
14
Screened Air Hood for 30% Outside Air Opening
14
Evaporative Cooling Module (Option AS3, AS4, AS5, or AS8)
14
Discharge Air Temperature Sensor Installation
14
Piping Connections
16
Gas Supply Pressure
16
Gas Supply Piping
17
Supply Piping Connections
17
Electrical Connections
19
Control Wiring
20
Controls
22
Thermostat
22
Remote Console
22
Combustion Air Proving Switch
22
Blower Fan Control
22
Limit Control
23
Reverse Flow Limit Control
23
High Ambient Limit Control
23
Airflow Proving Switch (Makeup Air with Option BW1)
23
Variable Frequency Drive
23
Combination Gas Valve
23
Optional Two-Stage Control (Heating Only Application)
23
Optional Two-Stage Control (Makeup Air Application)
24
Optional Ductstat with Capillary Tubing (Option AG3)
24
Optional Ductstat with Electronic Remote Setpoint Module (Option AG15)
25
Optional Electronic Modulation
25
Electronic Modulation between 50% and 100% Firing Rate (Option AG7, AG8, or AG9)
25
Computer-Controlled Electronic Modulation between 50% and 100% Firing Rate (Option AG21)
26
Electronic Modulation between 20-28% and 100% Firing Rate (Option AG39)
26
Electronic Modulation between 20-28% and 100% Firing Rate (Option AG40)
27
Pilot and Ignition Systems
29
Burners and Carryover System
29
Dampers and Damper Controls
30
Pressure Null Switch
30
Dirty Filter Switch
30
Operation
31
Pre-Startup Checklist
31
Startup
31
Post-Startup Checklist
32
Adjustments
32
Belts, Blowers, and Drives
32
Checking and Adjusting Belt Tension
32
Adjusting Blower Speed
33
Reversing Blower Rotation
33
Blower Motor Load and Amp Adjustment
33
Pressure Null Switch Adjustment
34
Measure and Adjust Manifold (Outlet) Gas Pressure
35
High Elevation (>2,000 Feet/609 Meters) Installations
36
Conversion to LP (Propane)
36
Dirty Filter Switch Adjustment
37
Burner Air Shutter Adjustment
38
Damper Linkage Adjustment
38
Maintenance
39
Service Checklist
39
Maintenance Procedures
39
Combination Gas Valve Maintenance
39
Burner Rack Maintenance
40
Cleaning Pilot and Burners
41
Spark Ignition System Maintenance
42
Heat Exchanger Cleaning
43
Troubleshooting
45
Installation Record (to be Completed by Installer)
48
Advertisement
Reznor RPB Manual (40 pages)
PACKAGED DUCT FURNACE AND BLOWER
Brand:
Reznor
| Category:
Furnace
| Size: 1 MB
Table of Contents
Table of Contents
2
General
2
Hazard Labels and Notices
2
General Installation Information
3
Warranty
3
Installation Codes
3
Furnace Location
3
General Recommendations
3
Combustion Air Requirements
3
Uncrating and Preparation
3
Uncrating and Inspecting
3
Preparing the Furnace for Installation
4
Dimensions and Clearances
4
Dimensions
4
Clearances
5
Mounting
5
Weights
5
Rigging and Lifting
5
Mounting Base and Methods
6
Mechanical
8
Gas Piping and Pressures
8
High Elevation (>2,000 Feet/609 Meters) Installations
12
Conversion to LP (Propane)
12
Venting
12
Unit Inlet Air
13
Supply Air Discharge
22
Blowers, Belts, and Drives
24
Electrical Supply and Connections
26
General
26
Supply Voltage and Supply Wiring
26
Wiring Diagrams
27
Thermostat, Other Optional Controls, and Control Wiring
27
Electrical Operating Components
28
Controls
29
Gas Controls
29
Pilot and Ignition Systems
33
Burners and Carryover System
34
Burner Air Adjustment
34
Check Installation and Startup
34
Check the Installation Prior to Startup
34
Startup
35
Check Installation after Startup
35
Maintenance and Service
36
Maintenance Schedule
36
Maintenance Procedures
36
Troubleshooting
38
Installation Record (to be Completed by Installer)
40
Reznor RPB Quick Start Manual (4 pages)
DOOR LATCH REPLACEMENT KIT INSTALLATION FOR AIR HANDLERS
Brand:
Reznor
| Category:
Air Handlers
| Size: 0 MB
Advertisement
Reznor RPB Installation (4 pages)
Brand:
Reznor
| Category:
Engine
| Size: 0 MB
Advertisement
Related Products
Reznor RPB Series
Reznor RP
Reznor RP 125
Reznor RP 150
Reznor RP 175
Reznor RP 200
Reznor RP 225
Reznor RP 250
Reznor RP 300
Reznor RP 350
Reznor Categories
Heater
Gas Heater
Furnace
Air Handlers
Electric Heater
More Reznor Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL