User Manuals: Protec 6100 Fire Alarm Panel
Manuals and User Guides for Protec 6100 Fire Alarm Panel. We have
3
Protec 6100 Fire Alarm Panel manuals available for free PDF download: Installation And Commissioning Manual, User Manual, Pc Programming Manual
Protec 6100 Installation And Commissioning Manual (52 pages)
SINGLE LOOP DIGITAL ADDRESSABLE FIRE ALARM CONTROL PANEL
Brand:
Protec
| Category:
Control Panel
| Size: 3 MB
Table of Contents
Appendix
2
Table of Contents
3
Important Notes - Please Read Carefully
5
Standards, Directives and Regulations Information
6
1 Items Supplied with the 6100
7
2 Items and Information Required Prior to Commissioning
7
Site Information Required to Commission the 6100
7
Items Required to Commission the 6100 Using the Windows Software
7
3 Introduction and Key Features
8
6100 Cabling Requirements
9
General
9
Mains Input Rating Label
9
Mains Wiring
9
Alarm Circuit Wiring
9
Fire Link Wiring
10
Addressable Loop Wiring and Devices
10
5 Insulation Testing of Cabling Prior to Connection
12
6 Installing the 6100
13
Unpacking
13
Removal of the Door
13
Disconnection of the Fire Brigade Panel (FBP) Connections
14
Removal of the Control PCB Housing
15
Preparing the Mounting Position and Cable Entries
16
Installing the Standby Batteries
16
Connecting the Standby Batteries
17
Refitting the Control PCB Housing
18
Connecting the Addressable Loop Wiring
18
Connecting the Conventional Alarm Circuit Wiring
18
Connecting the Fire Link Wiring
19
Connecting the Auxiliary Wiring
19
Connecting the Mains Cabling
20
Connecting the Fire Brigade Panel Controller
21
Re-Fitting the Door
21
Switching the Mains Power on
21
7 Commissioning the 6100
22
Terminology
22
Loop Device Input Group, Output Group and Zone Programming
22
Non Latching Loop Devices
22
Loop Device Class Programming
23
Loop Device Sensitivity Programming
24
Loop Sounder Volume Programming
24
Talking Sounder Programming Considerations
25
Fire Link Operation
26
Global Fire Contact Operation
27
Global Fault Contact Operation
27
Remote Alarm Input Operation
27
Class Change Input Operation
27
Conventional Alarm Output Operation
28
Output Group Type
28
Output Group Delays (T1 and T2)
28
Programming the Coverage Volume of Visual Alarm Devices (Vads)
30
Logging and Mapping Loop Devices
30
Programming Loop Device Address Data
32
Exchanging Loop Devices
34
Disabling / Enabling a Loop Device
35
Loop Device Remote Visual Address Verification ( RVAV )
36
Editing Device Location Text
37
Editing Zone Text
37
Clearing the Historic Fire Event Log
38
Clearing the Historic General Event Log
38
Displaying Loop Device Data
39
Displaying Panel Diagnostic Data
41
Displaying Panel Manufacturing Details
42
Connecting the 6100 to a PC
43
Restarting the 6100
43
8 Programming the System Using the Windows Software Suite
44
9 General System Operation
44
Panel Initialisation
44
Loop Initialisation
44
Added Loop Devices
44
10 0 6100 Technical Specification
45
Appendix 1 List of 6100 Spares and Accessories
46
6100 Control Pcb Housing
47
Appendix 3 Loop Devices Supported by the 6100
48
Appendix 4 6100 Event Descriptions
49
Advertisement
Protec 6100 User Manual (34 pages)
SINGLE LOOP DIGITAL ADDRESSABLE FIRE ALARM CONTROL PANEL
Brand:
Protec
| Category:
Control Panel
| Size: 1 MB
Table of Contents
Table of Contents
3
1 Introduction
5
2 User Responsibilities
6
Requirements of the Premises Management Named Person
6
3 Routine Testing of the System
7
Daily Inspection
7
Weekly Test
7
Monthly Test
7
Periodic Inspection
7
Annual Test
8
Yearly Test
8
6100 Access Levels
9
Access Level 1 ( General User )
9
Access Level 2 ( Authorised / Trained User )
9
6100 Indications and Controls
10
Multifunction Display
10
General Indications
10
Multifunction Zone Status Indications ( Row 2, First 16 Zones Only )
10
Code Entry and Menu Navigation Keys
10
Sound Alarms, Silence Alarms, Reset Panel and Mute Buzzer Keys
10
6100 Fire Indications
11
General Fire Indicator Illuminated
11
Multifunction Zone Indicator Flashing Red
11
6100 Fault Indications
11
Zone Faults
11
System Faults
11
Alarm Fault
11
Supply Fault
12
Aux. Supply Fault
12
Repeat Panel Fault
12
Fire Link Fault
12
6100 Disablement Indications
12
Zone Disablement
12
Alarm Disablement
12
Fire Link Disablement
12
9 Miscellaneous Indications
12
Power on Indication
12
10 System Delays
13
11 Coincidence Operation
13
6100 Response to an Alarm
14
Automatic Detection
14
Manual Detection
14
Coincidence Activation
14
Silencing the Alarms
14
Resetting the 6100 after an Alarm
14
New Zone in Alarm
14
Activating the Alarms Manually
14
6100 Status Displays
15
The System Normal Display
15
The Fault, Disablement and Test Display
15
The Fire Alarm Display
16
6100 User Menus
17
Entering the 6100 Menu System
17
User Menu Structure
17
Viewing Faults and Disablements
18
Clearing System Faults
19
Testing the Front Panel Indications
19
Setting a Zone into Walk Test Mode
20
Disabling a Zone
20
Disabling Alarm and Fire Link Outputs
21
Setting the Date and Time
21
Viewing the Alarm Counter
22
Viewing the Fire Event Log
22
Viewing the General Event Log
23
Exiting the Menus
23
6100 Fire Brigade Panel Operation (Australian Markets)
24
Enable Key
24
Silence Buzzer Button
24
Silence Alarms Button
24
Reset Button
24
Disable Button
24
16 Appendix 1 - 6100 System Set up Record
25
17 Appendix 2 - 6100 Event Log
28
18 Appendix 3 - 6100 Operation Quick Reference Guide
33
Entering Access Level 2
33
Returning to Access Level 1
33
Muting the Internal Buzzer and Accepting Current Faults
33
Sounding the Alarms
33
Silencing the Alarms
33
Resetting the 6100
33
Testing the Indicators and Internal Buzzer
33
Setting the Date and Time
33
Protec 6100 Pc Programming Manual (32 pages)
SINGLE LOOP DIGITAL ADDRESSABLE FIRE ALARM CONTROL PANEL
Brand:
Protec
| Category:
Control Panel
| Size: 1 MB
Table of Contents
Table of Contents
3
1 Important Notes - Please Read Carefully
5
2 Glossary of Terms
6
3 Introduction
8
4 Information Required Prior to Commissioning
9
Site Specific Information Required to Commission the 6100
9
5 Items Required to Commission the 6100 Using a Pc
9
PC / Laptop Requirements
9
Software and Hardware Requirements
9
6 Loading the 6100 Commissioning Software Onto a Pc
10
7 Connecting and Disconnecting the 6100 from the Pc
10
Connecting the PC to the 6100
11
Disconnecting the PC from the 6100
11
8 Overview of 6100 Commissioning Software Environment
12
The File Menu
13
The Edit Menu
13
The View Menu
14
The Panel Menu
14
The Help Menu
14
9 Creating a Site File
15
Creating a Blank Site File
15
Creating a Site File Using the Loop Commissioning Booklet
15
Creating a Site File by Logging and Mapping Devices Directly on the 6100
16
10 Programming Loop Device Data
16
Allocating a Zone Number to a Loop Input Device
16
Allocating an Input Group to a Loop Input Device
16
Allocating an Output Group to a Loop Output Device
16
Allocating an Output Group to the Conventional Alarm Outputs
16
Programming Loop Sounder Volume Levels
17
Allocating a Class to a Loop Device
17
Setting a Loop Input Device to be Latching or Non-Latching
17
Setting Automatic Detector Sensitivities
18
Programming Display Group Data
18
Programming Repeat Group Data
18
11 Programming Cause and Effect Sequences ( Matrix )
19
Setting up the Output Group Activation Tone
19
Setting up Output Group Delays
19
Programming the Output Group Type
20
Sound Alarms, Remote Alarm and Class Change Programming
20
Setting up Coincidence Operation
21
12 Entering Device, Zone and Panel Text
22
13 Programming Panel Configuration Data
23
Programming the Panel Access Codes
23
Programming the Global Fire and Fault Contact Operation
23
Programming the Fire Link Delay
24
Programming the Fire Link Search Time
24
Programming a First Knock Fire Link Delay Time
24
Programming the Walk Test Timeout
24
Programming Talking Sounder Options
25
Programming the Pulsing Alarm Timeout and Tone
25
Programming the System Pulsing Alarm Times
25
Programming Day and Night Sensitivity Times
26
Programming Remote Alarm Operation
26
Programming Class Change Operation
26
Programming Loop Beacon Operation
26
Overriding System Delays on a Second Knock Coincidence Activation
27
Pulsing the First Display Group into Alarm
27
Programming Loop Devices to 'Flash When Polled
27
Programming Dual Fire Link Outputs
27
14 Viewing Historic Event Logs
28
15 Uploading and Downloading Site Files to the 6100
28
Uploading a Site File from the 6100
28
Downloading a Site File to the 6100
28
Updating the 6100 Operating System
28
16 The Help Menu
28
Generating an Emergency Code ( Ecode )
28
Checking for Updates to the Commissioning Software
29
Downloading Online Documentation
29
Advertisement
Advertisement
Related Products
Protec Algo-Tec 6400
Protec Prodigy 640 DC
Protec Algo-Tec 6300
Protec Algo-Tec 6500
Protec Algo-Tec 6600
Protec 6000/LOOP/REPEATER
Protec 61-986-H2
Protec 61-986-H4
Protec 61-986-H1
Protec 61-986-H3
Protec Categories
Medical Equipment
Diagnostic Equipment
Control Panel
Security Sensors
Fire Alarms
More Protec Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL