Sign In
Upload
Manuals
Brands
otometrics Manuals
Measuring Instruments
AURICAL Aud
User Manuals: otometrics AURICAL Aud Audiometer
Manuals and User Guides for otometrics AURICAL Aud Audiometer. We have
2
otometrics AURICAL Aud Audiometer manuals available for free PDF download: Reference Manual, User Manual
otometrics AURICAL Aud Reference Manual (136 pages)
PC-controlled audiometer for testing a person's hearing
Brand:
otometrics
| Category:
Measuring Instruments
| Size: 3 MB
Table of Contents
Table of Contents
3
1 Introduction to AURICAL Aud
7
AURICAL Aud
7
Hi-Pro
8
AURICAL Speaker Unit
8
The Otosuite Audiometry Module
8
Noah
9
Intended Use
9
About this Manual
10
Installation and Assembly
10
Safety
10
Training
10
Typographical Conventions
10
Navigation
11
2 Navigating in the Otosuite Audiometry Module
13
The Audiometry Module Main Window
13
Menus and Toolbar Icons
13
File Menu
14
Edit Menu
14
View Menu
14
Measurement Menu
15
Tools Menu
16
The Patient Responder Indicator
16
The Masking Assistant
17
The Control Panels
19
Quick Select - Tone
20
Quick Select - Speech
21
Test Options
22
Monitor and Level
24
The Stimulus Bar
25
Test Controls
25
The Tone Stimulus Bar
26
The Speech Stimulus Bar
27
The Tone Test Screen
27
The Work Area in the Tone Screen
28
The Audiogram
28
Curves and Symbols Selection
30
Selecting a Symbol or Curve
30
Creating New Symbols
31
Compare Audiograms
32
Tone Feature Boxes
32
Tone Editing Options
34
Work-Flow Related Features
35
Selecting Orientation
35
Automatic Frequency/Level Shift When Storing
35
Stimulus Duration
36
Ear Shift Frequency and Level Setting
36
Saving Non-Stimulus Channel as Masking
36
The Speech Test Screen
36
Selecting Word or Phoneme Scoring
37
Selecting Speech Material
41
Scoring Words Using Integrated Otosuite Speech Material
43
Scoring Words Using External Sound Source
45
Scoring Phonemes Using Integrated Otosuite Speech Material
46
Scoring Phonemes Using External Sound Source
47
Saving Source Levels for Speech Material
48
Speech Testing - Tabular View
49
Creating and Editing the Speech Test Table
50
Speech Editing Options - Tabular View
51
Storing SNR for Speech Testing
52
Speech Testing - Graph View
52
Speech Editing Options - Graph View
54
Speech Feature Boxes
55
Terms and Abbreviations Used in Speech Testing
55
Special Tests
57
SISI (Short Increment Sensitivity Index)
57
Navigating in SISI
57
The Test Process - SISI
60
ABLB (Alternate Binaural Loudness Balance)
60
Navigating in ABLB
60
The Test Process
63
TEN (Threshold-Equalizing Noise)
63
Ambient Noise Assessor
64
Selecting the Freefit Device in Otosuite
64
Measuring Ambient Noise with AURICAL Freefit
64
Noise Level Indicators Stored with Measurements
67
Activating the Ambient Noise Assessor Automatically
68
Minimum HTL Per Transducer Type
69
Test Controls (Keyboard, Mouse)
69
PC Keyboard Controls
69
3 Preparing for Testing
71
Preparing the Test Environment
71
Preparing the Test Equipment
71
Listening Check
72
Preparing the Client
72
Hygienic Precautions
72
Inspecting the Client's Ear(S)
72
Proper Transducer Placement
72
4 Examples of Audiometric Testing
75
Testing the Older Child or Adult Patient
75
Assessing Pure Tone Threshold Using the Hughson/Westlake Procedure
75
Assessing Pure Tone or Speech most Comfortable Loudness Level (MCL)
76
Assessing Pure Tone or Speech Uncomfortable Loudness Level (UCL)
76
Assessing Speech Reception Threshold (SRT) Using the Hughson/Westlake Procedure
77
Assessing Word Recognition Score
77
Special Tests
78
Performing Tone Decay Using the Modified Carhart Method
78
Performing a Pure Tone Stenger
79
Performing Speech Stenger
79
Performing Weber
80
Performing Rinne
80
Performing Alternate Binaural Loudness Balancing (ABLB) Test
81
Performing Short Increment Sensitivity Index (SISI) Test
81
Testing with Sound Files
82
Playing Sound Files Without Word Lists
82
Playing Sound Files with Word Lists
82
Performing Sound-Field Speech Audiometry off Site
83
Enabling Portable Sound-Field Audiometry
83
Performing a Manual Calibration of AURICAL Aud Speakers
83
Using Manual Speaker Calibration Values
84
5 Unpacking and Installing
85
Requirements to the Location
85
Requirements to Noise in the Test Environment
85
Unpacking
86
Storing
86
Views of AURICAL Aud
86
AURICAL Aud
86
AURICAL Aud - with HI-PRO 2
87
AURICAL Speaker Unit
88
Connection Panels
88
AURICAL Aud Connection Panel
88
Built-In HI-PRO 2 Connection Panel
92
AURICAL Speaker Unit Connection Panel
92
Assembling AURICAL Aud
93
Desktop or Wall Installation
94
Connecting Accessories and PC to AURICAL Aud
95
Mounting AURICAL Aud on the Mounting Plate
95
AURICAL Speaker Unit Installation
95
Connecting Cables to the AURICAL Speaker Unit
96
Connecting Accessories and PC to AURICAL Aud
98
Mounting AURICAL Aud on the AURICAL Speaker Unit
99
Powering AURICAL Aud
99
6 Configuring the Audiometry Module
101
7 Communicating with the Device
103
Reconnecting to the Device
103
Updating Device Firmware
103
8 AURICAL Aud with HI-PRO
105
9 Tuning the AURICAL Aud Speaker for Use with Third-Party Applications
106
Microphone Placement for Use with Roomtune
106
Preparing to Use Roomtune
106
Using Roomtune in a New Environment
107
Using Roomtune to Keep AURICAL Aud Speakers in Tune
108
Cancelling Faulty Roomtune Data
109
Using Roomtune to Measure Sound Levels
109
Exiting Roomtune
110
10 Maintenance and Calibration
111
Service and Repair
111
Calibration
112
11 Troubleshooting
113
12 Standards and Safety
115
General Warning Notes
116
The Otosuite Audiometry Module
118
13 Technical Specifications
119
HI-PRO 2 (Built-In)
127
Notes on EMC (Electromagnetic Compatibility)
129
Index
133
Advertisement
otometrics AURICAL Aud User Manual (38 pages)
Brand:
otometrics
| Category:
Speaker System
| Size: 0 MB
Table of Contents
Table of Contents
3
Device Description
4
Intended Use
4
Unpacking
5
Installation
5
Connecting Accessories to AURICAL Aud
6
Powering the Device
8
Connecting AURICAL Aud to Otosuite
9
On-Screen Controls
9
PC Keyboard Controls
10
Toolbar Icons in the Audiometry Module
10
Proper Transducer Placement
12
The Masking Assistant
13
Performing Tone Audiometry
16
Performing Speech Audiometry
17
Service, Cleaning and Calibration
19
Other References
20
Technical Specifications
20
Definition of Symbols
34
Warning Notes
34
Manufacturer
37
Advertisement
Related Products
otometrics Aurical Hit
otometrics AccuScreen OAE
otometrics AccuScreen ABR
otometrics MADSEN Astera2
otometrics ABR Screener
otometrics Madsen AccuScreen PRO
otometrics Madsen Midimate 602
otometrics Madsen Xeta
otometrics Madsen ZODIAC 901
otometrics OTOsuite Hit module
otometrics Categories
Medical Equipment
Measuring Instruments
Headphone
Speaker System
Scanner
More otometrics Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL