otometrics AURICAL Aud User Manual
Hide thumbs Also See for AURICAL Aud:

Advertisement

AURICAL Aud
User Guide
Doc. No. 7-50-1270-EN/07
Part No. 7-50-12700-EN

Advertisement

Table of Contents
loading

Summary of Contents for otometrics AURICAL Aud

  • Page 1 AURICAL Aud User Guide Doc. No. 7-50-1270-EN/07 Part No. 7-50-12700-EN...
  • Page 2 Copyright notice © 2012, 2017 GN Otometrics A/S. All rights reserved. ® Otometrics, the Otometrics Icon, AURICAL, MADSEN, ICS and HORTMANN are registered trademarks of GN Otometrics A/S in the U.S.A. and/or other countries. Version release date 2017-03-12 (153432) Technical support Please contact your supplier. Otometrics - AURICAL Aud...
  • Page 3: Table Of Contents

    Device description Intended use Unpacking Installation Connecting accessories to AURICAL Aud Powering the device Connecting AURICAL Aud to OTOsuite On-screen controls PC keyboard controls 10 Toolbar icons in the Audiometry Module 11 Proper transducer placement 12 The Masking Assistant 13 Performing tone audiometry...
  • Page 4: Device Description

    AURICAL AudHI-PRO 2 with speaker unit with speaker unit AURICAL Aud is a PC-controlled audiometer for testing a person's hearing.The audiometer is operated from the OTOsuite Audiometry Module PC software. • With AURICAL Aud you can perform all standard audiometric tests, tone and speech audiometry and special tests.
  • Page 5: Unpacking

    3 Unpacking Use: The AURICAL speaker unit is intended to present audio signals. The AURICAL speaker unit is for use with AURICAL Aud and the Audiometry module, with AURICAL FreeFit and the OTOsuite PMM module and the OTOsuite Counseling and Sim- ulations module.
  • Page 6: Connecting Accessories To Aurical Aud

    It is a general rule for all electrical equipment used in the proximity of the client that: • The connected equipment must comply with IEC 60601-1 and/or IEC 60601-1-1 except for the PC, and equipment connected to the line in and the line out sockets of AURICAL Aud. Otometrics - AURICAL Aud...
  • Page 7 When you connect other electrical equipment to AURICAL Aud, remember that equipment that does not • comply with the same safety standards as AURICAL Aud can lead to a general reduction in the system's safety level. Connection panel - HI-PRO 2 The HI-PRO 2 connection panel contains the sockets for hearing...
  • Page 8: Powering The Device

    To connect AURICAL Aud to the mains supply, plug the mains plug into the wall mains outlet. To disconnect AURICAL Aud from the mains supply, pull the mains plug out of the wall mains outlet. Do not position the unit so that it is difficult to pull the mains plug out of the wall mains.
  • Page 9: Connecting Aurical Aud To Otosuite

    When you use AURICAL Aud for the first time, run the Configuration Wizard to set up the connection between AURICAL Aud and OTOsuite. After you have configured OTOsuite for the first time, if AURICAL Aud is turned on when you open the Control Panel in OTOsuite, then AURICAL Aud will connect to OTOsuite automatically.
  • Page 10: Pc Keyboard Controls

    Note The actual position of the keys may depend on your keyboard • type. Toolbar icons in the Audiometry Module The icons available in the toolbar depend on the test function that you have selected. Otometrics - AURICAL Aud...
  • Page 11 Enable or disable the Masking Assistant. Masking Assistant The Masking Assistant causes an unmasked threshold to flash repeatedly if masking is recommended. The graph shows up to 20,000 Hz. AURICAL Aud presents stimulus up to Standard / All / High 12,500 Hz. frequencies •...
  • Page 12: Proper Transducer Placement

    Insert earphones have greater attenuation between ears especially at the low frequencies; this reduces the need for masking. 2. It is best to clip the insert earphone transducers behind the child or on the back of their clothing and then fit the foam eartip into the child's ears. Otometrics - AURICAL Aud...
  • Page 13: The Masking Assistant

    The environment in which sound-field audiometry is performed may affect the sound field near the patient. The performance of loudspeakers for AURICAL Aud was tested by Otometrics under free-field conditions in a large anechoic chamber. Sound pressure level, frequency response and distortion were measured by a microphone placed 1 m from the front of the speaker.
  • Page 14 Pure Tone Hearing Thresholds, Audiologists’ Desk Reference - Vol 1, James W. Hall III, H. Gustav Mueller III, Singular Publishing Group 1997 Munro K.J., Agnew N. A comparison of inter-aural attenuation with the Ety- . and motic ER-3A insert earphone and the Telephonics TDH-39 supra-aural earphone. Br J Audiol 1999; 33: 259-262 Otometrics - AURICAL Aud...
  • Page 15 12 The Masking Assistant Min IA is frequency specific These are the Min IA tables for TDH-39 and Otometrics Inserts used in the Masking Assistant Min IA (supraaural phone: TDH-39), frequency specific Katz & Lezynski, (2002) Munro & Agnew, BJA (1999) Munro &...
  • Page 16: Performing Tone Audiometry

    Whenever the test buttons and other functions are used, you can use the corresponding keys on the keyboard, or the on- screen controls located at the top of the screen or in the Control Panel to the left. For detailed examples of audiometric testing, see the AURICAL Aud Reference Manual. Tone 1.
  • Page 17: Performing Speech Audiometry

    Whenever the test buttons and other functions are used, you can use the corresponding keys on the keyboard, or the on- screen controls located at the top of the screen or in the Control Panel to the left. For detailed examples of audiometric testing, see the AURICAL Aud Reference Manual. 1. Select the Speech screen in the OTOsuite Audiometry module.
  • Page 18 The desktop microphone should face the operator. If an external playback device is used to generate speech stimuli via the line input of AURICAL Aud, only a high quality CD player or similar device should be used; tape recordings may not provide a sufficient signal to noise ratio.
  • Page 19: Service, Cleaning And Calibration

    12. Repeat until all the measurements you need have been completed. Service, cleaning and calibration Warning Under no circumstances disassemble AURICAL Aud. Contact your supplier. Parts inside AURICAL Aud must • only be checked or serviced by authorized personnel. 15.1...
  • Page 20: Other References

    For instructions on installing OTOsuite, see the OTOsuite Installation Manual, which you can find on the OTOsuite install- ation medium (disk or memory stick). Technical specifications 17.1 AURICAL Aud Type identification AURICAL Aud is type 1081 from GN Otometrics A/S. Channels Two separate and identical channels. Frequency range Insert earphones: Standard frequencies: 125 - 8000 Hz...
  • Page 21 The following tables can be used to calculate the actual sound pressure level of the white noise signal for a given atten- uator setting (Table 1), or to select the attenuator setting required to obtain a specific level in dB SPL (Table 2). Otometrics - AURICAL Aud...
  • Page 22 The reference conditions for the specification of frequency response and sound pressure level depend on the type of audi- ometer. AURICAL Aud can be calibrated as either a “corrected” (Type AE) or “uncorrected” (Type A) speech audiometer: Type AE calibration: •...
  • Page 23 1 or 5 dB step resolution over the entire range. HL Range The maximum output levels from AURICAL Aud depend on the actual sensitivity of the individual transducers, and they will be slightly different for each unit. However, the minimum requirements from IEC and ANSI standards are fulfilled for all units.
  • Page 24 17 Technical specifications Distortion of signals occurs for higher stimulus levels. AURICAL Aud complies with IEC and ANSI standards with respect to maximum distortion. The following specification from IEC 60645-1:2001 applies: Specification of allowable distortion levels for airborne sound (test level and distortion)
  • Page 25 - For children and below normal skull size HB7 shall be applied (HB7 provides a greater force required to accommodate smaller skull size) For audiometric testing outside of noise attenuating test rooms, Otometrics recommends using earphones which feature passive noise reduction. For the applicable earphone models, the attenuation is specified in the following table.
  • Page 26 The maximum speech output level from the bone oscillator depends on the actual sensitivity of the vibrator. The actual maximum output is therefore determined at the time of calibration. The actual maximum output level may be determ- ined by the operator by simply increasing the output level until the attenuator setting no longer increases. Otometrics - AURICAL Aud...
  • Page 27 17 Technical specifications Additionally, AURICAL Aud includes a feature which allows the operator to select the maximum output level from a bone oscillator . Using this feature, the maximum output may be set lower than the physically available output level (installation option).
  • Page 28 • Should be extended if AURICAL Aud has been stored in a cold environment. Disposal AURICAL Aud can be disposed of as normal electronic waste, according to WEEE and local regulations. Dimensions AURICAL Aud: Approx. 275 x 205 x 60 mm, (10.8 x 8.0 x 2.4 inches) Weight AURICAL Aud with HI-PRO 2:...
  • Page 29 EN 60601-1, Class 1, Type BF and UL 544. EMC: EN 60601-1-2; EN 300 328-2; EN 301 489-17 Accessories • Test software. See the AURICAL Aud Service Manual. 17.3 AURICAL speaker unit Interfaces USB port output, type A Primarily for USB Bluetooth dongle...
  • Page 30 Monitor headphones with boom microphone • Desktop microphone • Talkback microphone • Patient Responder • Power supply and mains cable • Wall mounting plate • Connection cables • AURICAL FreeFit • AURICAL Aud Reference Manual • AURICAL Aud User Guide Otometrics - AURICAL Aud...
  • Page 31 Guidance and manufacturer's declaration - electromagnetic emissions for all equipment and systems AURICAL Aud is intended for use in the electromagnetic environment specified below. The user of AURICAL Aud should ensure that it is used in such an envir- onment.
  • Page 32 Guidance and manufacturer's declaration - electromagnetic immunity - for equipment and systems that are NOT life-supporting AURICAL Aud is intended for use in the electromagnetic environment specified below. The user of AURICAL Aud should ensure that it is used in such an envir- onment.
  • Page 33 Recommended separation distances between portable and mobile RF communications equipment and AURICAL Aud The AURICAL Aud is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the AURICAL Aud can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the AURICAL Audas recommended below, according to the maximum output power of the communications equipment.
  • Page 34: Definition Of Symbols

    This requirement applies in the European Union. Do not dispose of these products as unsorted municipal waste. You can return your device and accessories to Otometrics, or to any Otometrics supplier. You can also con- tact your local authorities for advice on disposal.
  • Page 35 • All connectors within the red frame are connected directly to patient transducers. Fig. 1 Sockets with direct connections to patient transducers - AURICAL Aud connection panel Isolated connectors • All connectors within the red frame are isolated from patient transducers.
  • Page 36 1. This class of equipment is allowed in domestic establishments when used under the jurisdiction of a health care pro- fessional. 2. AURICAL Aud is intended for diagnostic and clinical use by audiologists and other trained health care professionals in testing the hearing of their patients.
  • Page 37: Manufacturer

    Many types of electrical devices, e.g. mobile telephones, may generate radio fields. We recommend that the use of such devices in the vicinity of AURICAL Aud be restricted. Likewise, we recommend that the instrument is not used in the vicinity of devices sensitive to electromagnetic fields.
  • Page 38 • The equipment is used in accordance with the instructions for use. The manufacturer reserves the right to disclaim all responsibility for the operating safety, reliability and performance of equipment serviced or repaired by other parties. Otometrics - AURICAL Aud...