Sign In
Upload
Manuals
Brands
Olympus Manuals
Scanner
COBRA
Olympus COBRA Manuals
Manuals and User Guides for Olympus COBRA. We have
1
Olympus COBRA manual available for free PDF download: User Manual
Olympus COBRA User Manual (80 pages)
Handheld Pipe-Weld Scanner
Brand:
Olympus
| Category:
Scanner
| Size: 7.44 MB
Table of Contents
Table of Contents
3
List of Abbreviations
5
Figure I-1 Marking Locations
7
Labels and Symbols
7
Table 1 Symbols
8
Important Information - Please Read before Use
9
Intended Use
9
Instruction Manual
9
Instrument Compatibility
10
Table 2 Ancillary Equipment
10
Presence of Visual Interferences or Phantom Spots
13
Safety Symbols
14
Safety Signal Words
14
Note Signal Words
15
Safety
15
Warnings
16
CE (European Community)
16
WEEE Directive
16
Warranty Information
17
Technical Support
17
Figure I-2 the Omniscan MX2 and the COBRA Scanner
19
Introduction
19
Figure I-3 Operating the COBRA Scanner in a Limited Access Area
20
1 COBRA Scanner Description
21
Figure 1-1 the COBRA Scanner
21
Scanner Components
22
Figure 1-2 Scanner Component Identification
22
Figure 1-3 Link Types
23
Figure 1-4 Pipe-To-Component Interface Inspection with the One-Sided Scanner Configuration
23
About the Setup Templates
24
Figure 1-5 the Setup Templates
24
Table 3 Standard Tube an Pipe Ods Supported by the Setup Templates
25
Required Tools for Scanner Setup
26
Figure 1-6 Tools Included with the COBRA Scanner
26
Table 4 Required Tools (Included with the Scanner)
26
2 Setup and Operation
27
Removing the Probe
27
Installing the Probe
28
Figure 2-1 Removing the Sleeve Clamp
28
Figure 2-2 Installing the Protective Sleeve
29
Figure 2-3 Installing the Sleeve Clamp
29
Figure 2-4 Installing the Probe and the Wedge on the Scanner
30
Changing the Wedge
31
Figure 2-5 Changing the Wedge on the Scanner
31
Adjusting the Length of Exposed Cables and Tubes
32
Configuring the Scanner Using the Setup Template
33
Figure 2-6 Clipping the Tube and the Cable on the Post
33
Figure 2-7 the Tail-Adjustment Screw
34
Figure 2-8 Insert the Tail in Its Setup Template Pocket
35
Figure 2-9 Tightening the Tail-Adjustment Screw
35
Figure 2-10 Rotating the Tail to the Initial Position
36
Figure 2-11 Installing the Half-Link
37
Figure 2-12 Adjusting the Probe-Holder Position
37
Figure 2-13 Installing the Probe Holder into the Setup Template
38
Figure 2-14 Installing Male Links
38
Figure 2-15 Installing Female And/Or Medium Links
39
Figure 2-16 Rotating the Probe Holder to Set the Position for OD Larger
39
Figure 2-17 Rotating the Probe Holder to Set Position for OD Smaller than 33.4 MM (1.315 In.)
40
Figure 2-18 Rotating the Tail to Set Position for a Small Pipe Setup
40
Configuring the Scanner Without the Setup Template
41
Figure 2-19 Loosening the Links
42
Figure 2-20 Separating the Two Halves of the Scanner
43
Figure 2-21 the Graduated Crossbar
44
Figure 2-22 Example of Tail Configured to the 2.0 Position
45
Figure 2-23 the Probe Holder Shown in the Extended Position
45
Figure 2-24 Wrapping and Holding the Scanner
46
Using the Wedge-Separation Indicators
47
Figure 2-25 Placing the Wedge-Separation Indicator
48
Figure 2-26 Bringing the Wedge Faces Together
48
Operating the Scanner
49
Figure 2-27 Reading the Wedge Separation
49
Figure 2-28 Installing the Scanner on the Pipe
50
Figure 2-29 the Couplant Valve (Shown Open)
51
Figure 2-30 Rotating the Scanner
52
3 Maintenance and Troubleshooting
53
Cleaning the Scanner
53
Troubleshooting
53
Table 5 Troubleshooting Cases
54
4 Accessories and Spare Parts
57
Ordering Part Numbers
58
Table 6 COBRA Scanner Ordering Part Numbers
58
Table 7 Wedge Selection Chart
61
Figure 4-1 the Wedge Part Number
62
Figure 4-2 Content of the Basic Spare Part Kit (P/N: COBRA-SP-BASIC)
63
Table 8 Fittings and Tubing Spare Parts List (P/N: COBRA-SP-IRRIGATION)
63
Spare Parts
64
Figure 4-3 Exploded View
64
Table 9 COBRA Scanner Part List
65
5 Specifications
67
General and Operating Environment Specifications
67
Table 10 General Specifications
67
Connector Reference
68
Table 11 Operating Environment Specifications
68
Table 12 Required Encoder Cable Adaptor
68
Figure 5-1 LEMO Connector Pinout Diagram
69
Table 13 Omniscan MX2 Pinout for the Scanner Interface LEMO Connector
69
Probe Specifications
70
Scanner Setup Charts
70
Table 14 Standard Phased Array Probe Specifications
70
Table 15 Scanner Setup Chart for Smaller Pipes
71
Table 16 Scanner Setup Chart for Larger Pipes
72
List of Figures
73
List of Tables
75
Index
77
Advertisement
Advertisement
Related Products
Olympus ChainSCANNER
Olympus CAMEDIA C-5500 Sport Zoom
Olympus C-755 Ultra Zoom
Olympus CAMEDIA C-470 Zoom
Olympus ls-11 - With RS30 Wireless Remote Samson CH700 LS11 Skin
Olympus Camedia C-300 ZOOM
Olympus CHD
Olympus CX23
Olympus CK40-RFA
Olympus VISERA ELITE CLV-S190
Olympus Categories
Digital Camera
Voice Recorder
Microscope
Camera Accessories
Camera Lens
More Olympus Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL