Sign In
Upload
Manuals
Brands
Moxa Technologies Manuals
Network Router
ioLogik E2260
Moxa Technologies ioLogik E2260 Manuals
Manuals and User Guides for Moxa Technologies ioLogik E2260. We have
4
Moxa Technologies ioLogik E2260 manuals available for free PDF download: User Manual, Quick Installation Manual
Moxa Technologies ioLogik E2260 User Manual (144 pages)
Brand:
Moxa Technologies
| Category:
Network Router
| Size: 5 MB
Table of Contents
Copyright Notice
2
Table of Contents
3
1 Introduction
6
Product Key Features and Highlights
7
Package Checklist
7
Product Model Information
7
Product Selection Guide
8
Product Specifications
9
Common Specifications
9
Iologik E2210 Specifications
10
Iologik E2212 Specifications
11
Iologik E2214 Specifications
12
Iologik E2240 Specifications
13
Iologik E2242 Specifications
14
Iologik E2260 Specifications
15
Iologik E2262 Specifications
16
Physical Dimensions
17
Without LCM
17
With LCM
17
Hardware Reference
18
Panel Guide
18
Pin Assignments
18
LED Indicators
19
2 Initial Setup
20
Hardware Installation
21
Connecting the Power
21
Grounding the Unit
21
Software Installation
21
Restore Factory Defaults
23
Connecting to Ioadmin Via Ethernet
23
Configuring the Host Computer's IP Address
23
Activating Ioadmin and Connecting to the Iologik
24
Adding more I/O Channels
27
Setting the RS-485 Baudrate
28
I/O Wiring Diagrams
28
Using Ioadmin to Import/Export Configurations
30
3 Using Ioadmin
32
System Requirements
33
Features of Ioadmin
33
Ioadmin Overview
34
Main Screen Overview
34
Title
35
Menu Bar
35
Network Interface
37
Quick Links
41
Navigation Panel
41
Main Window
43
Sync Rate Status
45
Status Bar
45
Ioadmin Administrator Functions
45
I/O Configuration Tab (Administrator)
46
Virtual Channels
57
Server Settings Tab (Administrator)
59
Network Tab
60
Firmware Update Tab
61
Watchdog Tab
62
Click&Go Logic Tab
63
Active Tags Tab
64
SNMP Settings Tab
67
Message Monitor Panel (General)
68
Server Context Menu
69
Using Ioeventlog
71
Installing Ioeventlog
71
Basic Functions
71
Configuration
72
Checking Connected Devices
73
Opening Log Files
73
Clearing the Log
73
4 Click&Go
74
Overview
75
Features
75
Click&Go Logic Basics
76
Working with Rules
77
Click&Go Development Process
77
I/O Configuration
78
Digital Input Mode Selection
78
Digital Output Mode Selection
79
Analog Input Mode Selection
79
Alias Name Configuration
79
Testing the I/O Channels
80
Defining Global Variables
81
Internal Register (Integer) Settings
81
Timer Settings
82
SNMP Trap Server
82
E-Mail Server
83
Active Message Server
84
Working with Logic
85
Click&Go Logic Basics
85
IF Conditions
87
THEN/ELSE Actions
91
Activating the Rule-Set
100
Upload, Restart, and Run
100
Rule-Set Management Bar
100
Import/Export Configuration
100
More Information about Repeat Interval Vs. Edge Detection
101
5 Using the Web Console
103
Introduction to the Web Console
104
Overview
105
Basic Settings
105
Network Settings
106
General Settings
106
Ethernet Configurations
106
RS-485 Settings
106
I/O Settings
107
DI Channels
107
DO Channels
108
AI Channels
110
Alias Name
110
AO Channels
111
Relay Output Channel
111
Relay Count Motoring
112
Alias Name Set
113
RTD Channels
113
TC Channels
114
System Management
115
Accessible IP Settings
115
SNMP Agent
116
Network Connection
116
Firmware Update
116
Import System Config
117
Export System Config
117
Lcm
117
Change Password
117
Load Factory Default
118
Save/Restart
118
6 Active OPC Server
119
Active OPC Server
120
OLE for Process Control
120
Introduction to Active OPC Server
121
Active OPC Server-From Pull to Push
121
Features of Active OPC Server
122
One Click to Create Active Tags
122
Faster, more Accurate Data Collection than Traditional "Pull Technology
123
Active OPC Server Overview
123
Installing Active OPC Server
123
Main Screen Overview
124
Menu Bar
124
Tag Generation
128
Configuring Push Tag from Ioadmin
128
Heartbeat Interval
129
Read/Write Privilege
129
Liquid Crystal Display Module (LCM
130
LCM Controls
131
LCM Options
131
Used Network Port Numbers
133
Iologik E2200 Smart Ethernet Remote I/O Device Network Port Usage
133
Factory Default Settings
134
Cable Wiring
135
Device Wiring Diagrams
136
Analog Input
136
Analog Output
136
Digital Input Dry Contact
136
Digital Input Wet Contact
137
RTD Input Wiring
139
Thermocouple Input Wiring
140
Input and Output Terminal
141
Iologik E2210
142
Iologik E2212
142
Iologik E2214
142
Iologik E2240
143
Iologik E2242
143
Iologik E2260
143
Iologik E2262
144
Advertisement
Moxa Technologies ioLogik E2260 User Manual (89 pages)
Brand:
Moxa Technologies
| Category:
I/O Systems
| Size: 1 MB
Table of Contents
Table of Contents
3
Chapter 1. Introduction
6
Overview
7
Traditional Remote I/O
7
Active Ethernet I/O
7
Click&Go
8
Optional Liquid Crystal Display Module (LCM)
8
Product Features
8
Packing List
8
Product Specifications
9
Physical Dimensions
11
With LCD Module
11
Without LCD Module
12
Hardware Reference
12
Panel Guide
12
LED Indicators
13
Chapter 2. Initial Setup
14
Hardware Installation
15
Connecting the Power
15
Grounding the Iologik E2260
15
Connecting to the Network
15
Setting the RS-485 Baudrate
15
Adding more I/O Channels
16
Software Installation
16
Chapter 3. Utilities
18
Introduction to Ioadmin
19
Features of Ioadmin
19
Ioadmin Main Screen
21
Main Screen Overview
21
Wiring Guide
22
Menu Items
22
File
22
System
23
Sort
24
Help
24
Quick Links
24
Main Window
25
I/O Configuration Tab (General)
25
Server Info Tab
25
Server Settings Tab (General)
26
Message Monitor Tab
26
Ioadmin Administrator Functions
27
I/O Configuration Tab (Administrator)
27
Server Settings Tab (Administrator)
30
Network Tab
32
Firmware Update Tab
34
Watchdog Tab
34
Click&Go Logic Tab
35
Active Tags Tab
36
SNMP Settings Tab
37
Server Context Menu
37
Using TFTP to Import/Export Configuration
39
Using Ioeventlog
40
Installing Ioeventlog
40
Basic Functions
40
Configuration
41
Checking Connected Devices
42
Opening Log Files
42
Clearing the Log
43
Chapter 4. Using the Web Console
44
Introduction to the Web Console
45
Basic Settings
45
Network Settings
46
General Settings
46
Ethernet Configuration
46
RS-485 Settings
47
I/O Settings
47
RTD Channels
47
DO Channels
48
System Management
49
Accessible IP Settings
49
SNMP Agent
50
Network Connection
50
Firmware Update
51
Import System Config
51
Export System Config
51
Lcm
52
Change Password
52
Load Factory Default
52
Save/Restart
52
Chapter 5. Active OPC Server Lite
53
Overview
54
Introduction to Active OPC Server Lite
54
Active OPC Server Lite - from Pull to Push
55
Features of Active OPC Server Lite
56
Active OPC Server Lite Specifications
57
Installation of Active OPC Server Lite
57
Installation of OPC Core Components
57
Active OPC Server Lite
58
Main Screen Overview
58
Menu Items
59
File
59
System
59
Sort
60
Quick Links
60
Tag Generation
61
Push Tag Configuration from Ioadmin
61
Advanced Settings
63
Heartbeat Interval
63
Read/Write Privilege
64
OPC Test Client
64
Appendix A. Liquid Crystal Display Module (LCM
67
Appendix B. Modbus/Tcp Address Mappings
69
0Xxxx Read/Write Coils (Functions 1, 5, 15
69
3Xxxx Read Only Registers (Function 4
70
4Xxxx Read/Write Registers (Functions 3, 6, 16
71
Appendix C. Used Network Port Numbers
76
Appendix D. SNMP MIB II
77
RFC1213 MIB II Supported SNMP Variables
77
Private MIB File and SNMP Variables
80
Appendix F. Factory Default Settings
85
Appendix G. Pinouts and Cable Wiring
86
Ethernet Port Pinouts
86
Serial Port Pinouts
86
RTD Input Wiring
86
Structure
86
2-Wire
87
Digital Output
87
Structure
87
Output Channel
88
Terminal Block Pin Assignments
88
Appendix H. Accuracy
89
Calibration
89
Simple Verification at Your Site
89
Verification with RTD Sensor
89
Verification with Precision Resistor
89
Moxa Technologies ioLogik E2260 User Manual (106 pages)
Click&Go V2
Brand:
Moxa Technologies
| Category:
Computer Hardware
| Size: 2 MB
Table of Contents
Table of Contents
3
Chapter 1. Introduction
6
Overview
7
Click&Go V2 Features
8
Product and Software Support
8
Difference in Programming Method and Space
9
Difference in if Conditions
10
Difference in THEN/ELSE Actions
11
Click&Go Version Check
12
Chapter 2. Getting Started
13
Hardware Connection
14
System Requirements
14
Connecting to the Network
15
Optional Liquid Crystal Display Module (LCM)
15
Adding more I/O Channels
15
Connecting the I/O Device
16
Software Preparation
16
Ioadmin 3.X Installation
16
Firmware Update
19
Reset to Factory Default
20
Chapter 3. Click&Go V2 Developing Process
21
Click&Go V2 Development Process
22
I/O Configuration
22
Configurable DIO Channel Mode Selection
22
Digital Input Mode Selection
23
Digital Output Mode Selection
24
Analog Input Mode Selection
25
Analog Output Mode Selection
26
Temperature Input Mode Selection
26
Alias Name Configuration
28
Testing the I/O Channels
29
Define Global Variables
29
Internal Register Settings
30
Timer Settings
30
SNMP Trap Server
31
E-Mail Server
31
Active Message Server
32
Work with Logic
33
Click&Go Logic Basics
33
IF Conditions
36
More Info on Repeat Interval Vs. Edge Detection
46
THEN/ELSE Actions
49
Peer-To-Peer Function
62
Activating the Rule-Set
65
Download, Restart and Run
65
Rule-Set Management Bar
65
Import/Export Configuration
66
Using Ioadmin to Import/Export Configuration
66
Using TFTP to Import/Export Configuration
68
Click&Go Rule 101
69
If-Then-Else
70
Where There Is an on Logic, There Should be an off Logic
70
Rules Are Running in a Loop
70
Using the Timer Function
71
Heartbeat or Repeat Actions
71
ON-Delay
72
OFF-Delay
73
Using Internal Registers
73
Soft-Key
73
Remote Control
73
Programming Examples
74
Local I/O Control
74
Active I/O Messages
75
Peer-To-Peer I/O
77
Applications_1
80
Project Background
80
Application Requirements
80
Moxa Solution
80
Solution Benefits
80
Additional Features
81
System Diagram
81
Click&Go Programming Example
82
Applications_2
83
Application Requirements
83
Moxa Solution
83
Solution Benefits
83
Additional Features
84
System Diagram
84
Applications_4
89
Applications_5
92
Applications_6
95
Applications_7
98
Additional Features
99
System Diagram
99
Click&Go Programming Example_Site
100
Click&Go Programming Example_Central
103
Appendix A. Internal Registers - Modbus/Tcp Address Mappings
105
Iologik E2210, E2212 and E2214
105
4Xxxx Read/Write Registers (Functions 3, 6, 16
105
Iologik E2240, E2242, E2260 and E22262
106
4Xxxx Read/Write Registers (Functions 3, 6, 16
106
Advertisement
Moxa Technologies ioLogik E2260 Quick Installation Manual (6 pages)
Smart Ethernet Remote I/O
Brand:
Moxa Technologies
| Category:
I/O Systems
| Size: 0 MB
Table of Contents
Package Checklist
2
Specifications
2
Led Indicators
3
Environmental Limits
3
I/O Wiring Diagrams
4
Restore Factory Defaults
5
Mounting
5
Connecting to the Iologik E2200
5
How to Download the Software
6
Advertisement
Related Products
Moxa Technologies ioLogik E2200Series
Moxa Technologies ioLogik E2262
Moxa Technologies ioLogik E2214
Moxa Technologies ioLogik E2240
Moxa Technologies EtherDevice EDR-G903
Moxa Technologies EDS-305-M12
Moxa Technologies EDS-405-SS-SC
Moxa Technologies EDR-810 Series
Moxa Technologies EDS-G512E-8PoE
Moxa Technologies EDS-210A-1GSFP-1SFP
Moxa Technologies Categories
Switch
Server
Desktop
Gateway
Media Converter
More Moxa Technologies Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL