Measuring Instruments
GenTwo PMA1000V2.4
M&C GenTwo PMA1000V2.4 Manuals
Manuals and User Guides for M&C GenTwo PMA1000V2.4. We have
1
M&C GenTwo PMA1000V2.4 manual available for free PDF download: Instruction Manual
M&C GenTwo PMA1000V2.4 Instruction Manual (110 pages)
Multigas Analyzer
Brand:
M&C
| Category:
Measuring Instruments
| Size: 4.37 MB
Table of Contents
Table of Contents
3
About this Instruction Manual
6
Important Safety Information
7
Intended Use
7
Personal Safety
7
Warning Signs and Definitions
7
Safety Instructions
9
Working on Electrical and Electronic Devices
10
Not Certified in Hazardous Areas
10
Introduction
11
Product Overview
12
Receiving the Analyzer
13
Rack-Housing: Warning Symbols and Product Label
13
Fig. 1: Warning Symbols and Product Label on the Back
13
Wall-Mount Housing: Warning Symbols and Product Label
14
Fig. 2: Product Label on the Side of the Wall-Mount Housing
14
Fig. 3: Warning Symbol at the Bottom of the Wall-Mount Housing
14
Fig. 4: Warning Symbols Inside Wall-Mount Housing
15
Fig. 5: Warning Symbol Close to the Relay Connections (Cover Removed)
15
Fig. 6: Paramagnetic Measuring Cell
16
Paramagnetic Oxygen Sensor (PMA2)
16
Measuring Principles
16
Fig. 7: Electronic Evaluating System to Measure Oxygen Concentration
17
Technical Data Basic Instrument
18
Dimensions 19" Rack Housing
20
Fig. 8: 19" Rack Housing Front View
20
Fig. 9: 19" Rack Housing Side View (Long Housing)
20
Dimensions Wall-Mount Housing
21
Connections 19"-Rack Device
21
Fig. 10: Wall-Mount Housing, Front and Side-View
21
Fig. 11: Back View of 19" Rack Housing with Connections (Max. Equipped)
21
Fig. 12: Bottom-View of Wall-Mount Device with Connections
22
Fig. 13: Power Supply Connections Inside Wall-Mount Device (W/O Protective Covers)
22
Fig. 14: Signal Connections Inside Wall-Mount Device (Max. Equipped)
23
Electrical Interfaces: 19" Rack Housing
24
Fig. 15: Electrical Interfaces: 19" Rack Housing
24
Electrical Interfaces: Wall-Mount Housing
25
Fig. 16: Electrical Interfaces: Wall-Mount Housing
25
System Functions
26
Status Alarm
26
Accuracy of Ma Readings
26
Fig. 17: Startup Screen
27
How to Use the Touch Screen
27
Using the Analyzer
27
Graphical User Interface (GUI)
27
Menu Structure
28
System Status Line
29
Fig. 18: Menu Structure Overview M2/S2
29
Main Menu Bar
30
Fig. 19: System Status Line
30
Fig. 20: Menu Bar with the Menu Items M1 to M6
30
Fig. 21: Main Display Area M2/S2
31
Fig. 22: Available Languages/Flags
31
Language Selection
31
Main Display Area
31
M1/S1 and M1/S2 - M&C Contact and GUI Version Number
32
Fig. 23: M1/S1 - M&C Contact Information
32
Fig. 24: Swipe to Navigate through the Sections
32
Fig. 25: M1/S2 - Analyzer Configuration
33
Fig. 26: Detailed Information about the GUI Software Version
33
Fig. 27: Navigate Back to the M1/S1 Section
33
M1/S4 - Operating Hours Counter
34
M2/S1, M2/S2 - Measured Values, Operational Parameters and Limits
34
Fig. 28: M1/S4 - Operating Hours Counter (OHC)
34
Fig. 31: Navigate Back to the Start Screen
35
Fig. 30: M2/S2 - Detailed View of the Measuring Parameters
35
Fig. 29: M2/S1 - Start Screen of the Home Button
35
Fig. 32: M2/S2 - Detailed View During Warm-Up Period
36
Fig. 33: M2/S2 - Using the Zoom Button
36
M2/S3 - Event List
37
Fig. 34: Zoomed and Highlighted Area
37
Fig. 35: M2/S3 - Event List
37
M3/S1 - Data Logger/History Archive
38
Fig. 36: M3/S1 Data Logger Screen
38
Fig. 37: M3/S1 - Recorded Data Selection Screen
38
Fig. 38: Calibration Symbols to Highlight Calibration Procedures
39
M4/S1 - Measuring Range Selection, Sensor Evaluation, Lim Settings
39
Fig. 39: M4/S1 Edit Buttons for Measuring Range and Operational Parameter Settings
40
Fig. 40: Highlighted Scroll Bar to Select Measuring Range
40
Fig. 41: Sensor Evaluation List
41
Fig. 42: Highlighted Scroll Bars to Set Operational Parameter Lim1
42
M4/S2 - Settings Menu/ Parameters
43
Fig. 43: Highlighted Scroll Bar to Set Operational Parameter Lim2
43
Fig. 44: M4/S2 Screen with "Restart" Button
44
Fig. 45: Channel Settings
45
Fig. 46: Basic Settings for Channel 1
46
Fig. 47: Keypad
46
Fig. 48: Channel-Specific Settings List
47
Fig. 49: System Settings
49
Fig. 50: Scroll Bar with "4=Updates" Displayed in the Gray Frame
50
Fig. 51: Buttons to Get Information and Install Hardware and Software Updates
50
Fig. 52: Screen to Confirm the Update of the Application Software
51
Fig. 53: M4/S2 Screen with "Factory Reset" Selected
51
Fig. 54: Select Factory Settings
52
Fig. 55: Database Settings
52
Fig. 56: IP Address Input Screen
53
Fig. 57: Date and Time Settings
54
Fig. 59: PDF1 Update
55
Fig. 58: Supervisor Settings for Administrators
55
Fig. 60: Scroll Bar with "B=Diagnosis" Displayed in the Gray Frame
56
Fig. 61: Schematic for Diagnosis
56
Fig. 62: IO1 Component: DO1 to 4, Relay Outputs R1, R2 and Ma Output
57
Fig. 63: Display of the Highlighted IOAC-0 Components
57
M5/S1 and M5/S2 Calibration Menu
58
Fig. 64: Service Settings
58
Fig. 65: Gas Calibration Screen
58
M6/S1 Help Button
59
Fig. 66: Adjust Pressure Gauges and Flow Sensor
59
General
60
Mounting and Installation
60
Wall-Mount Housing: Electrical Connection
61
Fig. 67: Power Supply Connections Inside Wall-Mount Housing
62
Starting-Up and Operating the Analyzer
63
Preparations for Start-Up
63
Start-Up and Operation
63
Fig. 68: Warm-Up Phase in M2/S1 and Warm-Up Info on M2/S2
63
Fig. 69: Analyzer Is Ready to Operate
64
Confirm System Messages
65
Fig. 70: Manual Calibration (Manucal)
66
General
66
M5/S1 Manual Calibration (Manucal)
66
Calibration
66
Fig. 71: Setting the Channel-Specific Calibration Parameters
67
Fig. 72: Manual Calibration with Span Gas
67
Fig. 73: First Step of the Manual Calibration Procedure
68
Fig. 74: Second Step of the Manual Calibration Procedure
68
Fig. 75: Third Step of the Manual Calibration Procedure
69
Fig. 76: End of the Manual Calibration Procedure
69
Fig. 77: Data Logger Screen with Calibration Symbols
70
Fig. 78: a Terminated Manual Calibration Procedure
70
Fig. 80: Datalogger Screen with Red Calibration Symbol
71
Fig. 79: Manual Calibration Error
71
Automatic Calibration (Autocal)
72
Fig. 81: Screen Showing Details about a Single Calibration Procedure
72
Fig. 82: Activating Autocal and Entering Parameters
72
Autocal for External Mounting of the Solenoid Valves
74
Fig. 83: Diagnostic Diagram: Opening the Output Card "IOAC 0
74
Fig. 84: Diagnostic Diagram: Opened Output Card
74
Fig. 85: Autocal Extern. Valves: Zero and Span Gas Via Gas Cylinder
75
Fig. 86: Autocal Ext. Valves: Span Gas Via Filter and Pump, Zero Gas Via Gas Cylinder
75
Fig. 87: Autozero with Gas Cylinder for Zero Gas
76
Example: Autozero with Zero Gas
76
Setting the Ma Behaviour During Calibration
77
Fig. 88: Autocal-Start Without Setting an Autocal Interval
77
Parameter Settings for Automatic Calibration
78
Fig. 89: Ma Setting: Page M4/S2, 3=Calibration/Adjustment
78
Fig. 90: Parameter Settings for Autocal
78
Fig. 91: Parameter Settings for Autocal: Section
78
Adjust Pressure Gauges and Flow Sensor
79
Fig. 92: Adjust Pressure Gauges and Flow Sensor
79
Cross-Sensitivity of Coexisting Gases
80
Cross-Sensitivity of Oxygen Sensor (PMA2)
80
Fig. 93: Formula to Calculate the Effects of Coexisting Gases
81
Cleaning and Decontamination
84
Service and Maintenance
84
Recommended Maintenance Work
85
Options and Spare Parts List
86
Appendix
89
Trouble Shooting
89
AK Protocol
89
Modbus Protocol
92
Additional Information
100
Declaration of Conformity
100
Liability and Disclaimer
101
Certificates
101
Warranty
101
Storage
102
Shipping and Handling
102
Proper Disposal of the Device
102
About Us
103
M&C's Group of Companies
103
The Quality-Oriented M&C Catalog
104
Technical Consulting Services
105
Ideas, Suggestions and Feedback
105
Table of Illustrations
106
Advertisement
Advertisement
Related Products
M&C PMA Series
M&C PMA 45K1
M&C PMA 30/D
M&C PMA 30/A/D
M&C GenTwo Multigas V2.4
M&C GENTWO PMA1000
M&C GENTWO PMA1000L
M&C PMA05 MB10
M&C PMA05 MB01
M&C PMA 20
M&C Categories
Water Pump
Measuring Instruments
Accessories
Industrial Equipment
Analytical Instruments
More M&C Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL