Sign In
Upload
Manuals
Brands
Hioki Manuals
Measuring Instruments
IM3536
Hioki IM3536 General Purpose LCR Manuals
Manuals and User Guides for Hioki IM3536 General Purpose LCR. We have
5
Hioki IM3536 General Purpose LCR manuals available for free PDF download: Instruction Manual, Communication Instruction Manual
Hioki IM3536 Instruction Manual (276 pages)
LCR METER
Brand:
Hioki
| Category:
Measuring Instruments
| Size: 7 MB
Table of Contents
Table of Contents
3
Introduction
7
Verifying Package Contents
7
Measurement Process
12
Safety Information
16
Operating Precautions
18
1 Overview
23
Product Overview and Features
23
Names and Functions of Parts
24
Screen Layout and Operation
26
X84; Screen Transition Diagram
26
X84; Viewing Measured Values (Measurement Screen)
28
X84; Select the Measurement Mode (MODE Screen)
30
X84; Setting Detailed Settings such as Measurement Conditions (SET Screen)
31
X84; Checking Measurement Condition Settings Information
32
X84; Configuring Correction Functionality (ADJ Screen)
33
X84; Configuring the Instrument's Interfaces, Setting the Time and Date, and Checking the System (SYS Screen)
34
X84; Displaying and Manipulating Files on the USB Flash Drive (FILE Screen)
35
2 Measurement Preparations
37
Preparation Flowchart
37
Pre-Operation Inspection
39
Connecting the Power Cord
40
Connecting the Measurement Cables, Probes, or Fixture
41
Turning the Power on and off
42
Setting the Date and Time
44
3 Performing Measurements in LCR Mode
45
Setting Display Parameters
45
X84; to Perform DC Measurement (DC Resistance Measurement)
46
Viewing Measured Values
47
Enlarging Display of Measurement Values
48
Setting Measurement Conditions (Basic Settings)
49
X84; Required Settings
50
X84; User-Configurable Settings
60
X84; Measurement and Data Acquisition Timing
71
Permittivity
73
Judging Measurement Results
74
X84; Setting the Judgment Mode
75
Based on One Judgment Standard)
75
Multiple Judgment Standards)
80
Setting Application Settings
85
Individual Measurement Ranges
85
Measurement Speed)
88
X84; High-Z Reject Function (Detecting Contact Errors During 2-Terminal Measurement)
90
(Detecting Poor Contact with the Sample During 4-Terminal Measurement)
91
(Saving Measurement Results)
92
X84; Number of Effective Digits of the Measurement Value
93
X84; LCD Display Auto-Off (Power-Saving Mode)
94
X84; Key Tones and Judgment Tones
95
X84; Key-Lock Function (Disabling Key Operation)
96
4 Using Continuous Measurement Mode
99
Setting Which Panels to Use in Continuous Measurement
99
Performing Continuous Measurement
100
Checking Continuous Measurement Results
100
Changing the Display Timing Setting (When You Wish to Shorten the Screen Update Interval)
101
Setting the LCD Display Auto-Off (When You Wish to Save the Power)
102
5 Error Correction
103
Setting the Cable Length (Cable Length Correction)
104
Open Correction
105
X84; before Performing Open Correction
105
X84; All Correction
106
X84; Spot Correction
109
Short Correction
111
X84; before Performing Open Correction
111
X84; All Correction
112
X84; Spot Correction
113
If Open or Short Correction Fails to Complete Normally
115
Disabling Open and Short Correction Values
117
Load Correction (Correcting Values to Match Reference Values)
118
X84; Procedures for the Load Correction
119
X84; to Reset the Correction Condition Settings
125
X84; When Load Correction Fails to Complete Normally
125
X84; Disabling Load Correction
126
Correcting Measured Values with a User-Specified Correction Coefficient (Correlation Correction)
127
6 Saving and Loading Measurement Condition and Correction Value Data
129
Saving Measurement Conditions and Correction Values (Panel Save Function)
130
Loading Measurement Conditions and Correction Values (Panel Load Function)
134
Changing a Panel Name
135
Deleting a Panel
136
7 Setting the System
137
Setting the Interface (Controlling the Instrument from a Computer)
138
Checking the Version of the Instrument
138
Testing the System (Self Diagnosis)
139
X84; Panel Test
139
X84; Panel Calibration
140
LED Status
140
X84; ROM/RAM Test
141
X84; Testing EXT I/O Input/Output Signals
141
8 Using USB Flash Drive (Saving and Loading Data)
143
Inserting and Removing a USB Flash Drive
144
Checking the Contents of Files on a USB Flash Drive
145
Formatting a USB Flash Drive
146
Saving Measurement Data
147
X84; Saving Measurement Data in Text
147
X84; Saving a Copy of the Screen
156
X84; to Specify the Save Folder
158
Saving Settings Data
159
X84; Saving Instrument Settings Other than Panels
159
Panels (ALL SAVE Function)
160
Loading Instrument Settings
161
X84; Loading Settings Files or Panel Files
161
Files (ALL LOAD Function)
162
Checking the Contents of a File
163
Deleting Files and Folders
164
Creating Folders
165
Displaying the USB Flash Drive Information
166
9 External Control
167
External Input/Output Connector and Signals
168
Connectors
168
X84; Instrument Connector Signal Assignments 162 „ Input (IN) Signal Function Details
173
X84; BCD Mode Function Details
174
X84; Output Signals When Errors Occur
176
Example Measurement Timing (Timing Charts)
177
Internal Circuitry
182
X84; Circuit Diagrams
182
X84; Electrical Specifications
184
X84; Connection Examples
184
External I/O Settings
186
Judgment Result Reset Operation
187
X84; Disabling the Trigger Input During Measurement and Setting the Trigger
188
Output Time
189
X84; Outputting Measured Values (Switching to BCD Mode) *LCR Mode Only
190
External Control Q&A
191
Result Output to EOM Output) and Judgment Result Reset Operation
191
Measurement Using a Computer
192
10 Specifications
193
General Specifications
193
Environmental and Safety Specifications
198
Accessories and Options
199
Function Specifications
199
Interfaces
211
Measurement Range and Accuracy
213
About Measurement Times and Measurement Speed
223
11 Maintenance and Service
227
Calibration, Inspection, Repair, and Cleaning
227
X84; Calibrations
227
X84; Inspection and Repair
227
X84; Replaceable Parts and Operating Lifetimes
227
X84; Transporting the Instrument
228
X84; Cleaning
228
Troubleshooting
229
X84; before Returning for Repair
229
X84; Initializing (System Reset)
234
X84; Performing a Full Reset (if You Are Unable to Perform a System Reset)
235
Error Massage and Error Display
236
Discarding the Instrument
241
Formula
243
Appendix Appx
243
Appx. 3 Measurement of In-Cir Cuit Components
246
External Noise
247
X84; Countermeasures against Incorporation of Noise from the Power Line
247
X84; Countermeasures against Noise from the Measurement Cables
248
Appx. 5 Supplying DC Bias
248
X84; How to Supply a DC Bias Voltage
249
X84; How to Supply a DC Bias Current
250
Appx. 6 the Residual Charge Protection Function
251
Appx. 7 Series Equivalent Circuit Mode and Parallel Equivalent
252
Short Correction
253
Appx. 8 Open Correction and Short Correction
253
Hardware to the Instrument Appx
254
Appx.12
255
Appx. 10 Dimensional Diagram
256
Appx. 11 Initial Settings Table
257
Appx. 12 Device Compliance Statement
264
Advertisement
Hioki IM3536 Instruction Manual (270 pages)
LCR METER
Brand:
Hioki
| Category:
Measuring Instruments
| Size: 7 MB
Table of Contents
Table of Contents
2
Introduction
5
Verifying Package Contents
5
Measurement Process
10
Safety Information
14
Operating Precautions
16
Overview
21
Product Overview and Features
21
Names and Functions of Parts
22
Screen Layout and Operation
24
X84; Screen Transition Diagram
24
X84; Viewing Measured Values (Measure- Ment Screen)
26
X84; Select the Measurement Mode (MODE Screen)
28
X84; Setting Detailed Settings such as Mea- Surement Conditions (SET Screen)
29
X84; Checking Measurement Condition Set- Tings Information
30
X84; Configuring Correction Functionality (ADJ Screen)
31
X84; Configuring the Instrument's Interfaces, Setting the Time and Date, and Checking the System (SYS Screen)
32
X84; Displaying and Manipulating Files on the USB Flash Drive (FILE Screen)
33
Measurement Preparations
35
Preparation Flowchart
35
Pre-Operation Inspection
37
Connecting the Power Cord
38
Connecting the Measurement Cables, Probes, or Fixture
39
Turning the Power on and off
40
Setting the Date and Time
42
Performing Measurements in LCR Mode
43
Setting Display Parameters
43
X84; to Perform DC Measurement (DC Resis- Tance Measurement)
44
Viewing Measured Values
45
Enlarging Display of Measurement Values
46
Setting Measurement Condi- Tions (Basic Settings)
47
X84; Required Settings
48
X84; User-Configurable Settings
59
X84; Measurement and Data Acquisition Timing
70
X84; When Measuring Conductivity and Per- Mittivity
72
Judging Measurement Results
73
X84; Setting the Judgment Mode
74
Based on One Judgment Standard)
74
Judgment Standards)
79
Setting Application Settings
84
X84; Range Synchronization (Setting Mea- Surement Conditions for Individual Mea- Surement Ranges)
84
X84; Waveform Averaging Function (Increas- Ing Measurement Precision or Measure- Ment Speed)
87
X84; High-Z Reject Function (Detecting Contact Errors During 2-Terminal Measurement)
89
X84; Contact Check Function (Detecting Poor Contact with the Sample During 4-Termi- Nal Measurement)
90
X84; Memory Function (Saving Measurement Results)
91
X84; Number of Effective Digits of the Mea- Surement Value
92
X84; LCD Display Auto-Off (Power-Saving Mode)
93
X84; Key Tones and Judgment Tones
94
X84; Key-Lock Function (Disabling Key Operation)
95
Using Continuous Measurement Mode
97
Setting Which Panels to Use in Continuous Measurement
97
Performing Continuous Measurement
98
Checking Continuous Measurement Results
98
Changing the Display Timing Setting (When You Wish to Shorten the Screen Update Interval)
99
Setting the LCD Display Auto-Off (When You Wish to Save the Power)
100
Error Correction
101
Setting the Cable Length (Cable Length Correction)
102
Open Correction
103
X84; before Performing Open Correction
103
X84; All Correction
104
X84; Spot Correction
107
Short Correction
109
X84; before Performing Open Correction
109
X84; All Correction
110
X84; Spot Correction
111
If Open or Short Correction Fails to Complete Normally
113
Disabling Open and Short Correction Values
115
Load Correction (Correcting Values to Match Reference Values)
116
X84; Procedures for the Load Correction
117
X84; to Reset the Correction Condition Settings
123
X84; When Load Correction Fails to Complete Normally
123
X84; Disabling Load Correction
124
Correcting Measured Values with a User-Specified Correction Coefficient (Correlation Correction)
125
Saving and Loading Measurement Condi- Tion and Correction Value Data
127
Saving Measurement Conditions and Correction Values (Panel Save Function)
128
Loading Measurement Condi- Tions and Correction Values (Panel Load Function)
132
Changing a Panel Name
133
Deleting a Panel
134
Setting the System
135
Setting the Interface (Controlling the Instrument from a Computer)
136
Checking the Version of the Instrument
136
Testing the System (Self Diagnosis)
137
X84; Panel Test
137
X84; Panel Calibration
138
LED Status
138
X84; ROM/RAM Test
139
X84; Testing EXT I/O Input/Output Signals
139
Using USB Flash Drive (Saving and Loading Data)
141
Inserting and Removing a USB Flash Drive
142
Checking the Contents of Files on a USB Flash Drive
143
Formatting a USB Flash Drive
144
Saving Measurement Data
145
X84; Saving Measurement Data in Text
145
X84; Saving a Copy of the Screen
154
X84; to Specify the Save Folder
156
Saving Settings Data
157
X84; Saving Instrument Settings Other than Panels
157
Panels (ALL SAVE Function)
158
Loading Instrument Settings
159
X84; Loading Settings Files or Panel Files
159
Files (ALL LOAD Function)
160
Checking the Contents of a File
161
Deleting Files and Folders
162
Creating Folders
163
Displaying the USB Flash Drive Information
164
External Control
165
External Input/Output Connector and Signals
166
Connectors
166
X84; Instrument Connector Signal Assignments 162 „ Input (IN) Signal Function Details
171
X84; BCD Mode Function Details
172
X84; Output Signals When Errors Occur
174
Example Measurement Timing (Timing Charts)
175
Internal Circuitry
180
X84; Circuit Diagrams
180
X84; Electrical Specifications
182
X84; Connection Examples
182
External I/O Settings
184
X84; Setting the Delay Time (from Judgment
185
X84; Disabling the Trigger Input During Mea- Surement and Setting the Trigger Input
186
Output Time
187
To BCD Mode) (LCR Mode Only)
188
External Control Q&A
189
Measurement Using a Computer
190
Specifications
191
General Specifications
191
Environmental and Safety Specifications
196
Accessories and Options
197
Function Specifications
197
Interfaces
209
Measurement Range and Accuracy
211
About Measurement Times and Measurement Speed
221
Maintenance and Service
225
Calibration, Inspection, Repair, and Cleaning
225
X84; Calibrations
225
X84; Inspection and Repair
225
X84; Replaceable Parts and Operating Life- Times
225
X84; Transporting the Instrument
226
X84; Cleaning
226
Troubleshooting
227
X84; before Returning for Repair
227
X84; Initializing (System Reset)
232
X84; Performing a Full Reset (if You Are Unable to Perform a System Reset)
233
Error Massage and Error Display
234
Discarding the Instrument
239
Formula
241
External Noise
245
Of Noise from the Power Line
245
X84; Countermeasures against Noise from the Measurement Cables
246
Appx. 5 Supplying DC Bias
246
X84; How to Supply a DC Bias Voltage
247
X84; How to Supply a DC Bias Current
248
Equivalent Circuit Mode Appx.10
250
Short Correction
251
Instrument
252
Appx. 10 Dimensional Diagram
254
Appx. 11 Initial Settings Table
255
Hioki IM3536 Communication Instruction Manual (74 pages)
Brand:
Hioki
| Category:
Measuring Instruments
| Size: 1 MB
Table of Contents
Table of Contents
3
Introduction
5
Safety Information
5
Chapter 1 Specifications
7
RS-232C Specifications
7
GP-IB Specifications
8
USB Specifications
8
LAN Specifications
8
Chapter 2 Model IM3570/ IM3536 Connection and Setting
9
Overview of Communication
9
RS-232C Connection and Settings
11
Connecting the RS-232C Cable
11
Setting RS-232C
12
GP-IB Connection and Settings
13
USB Settings and Connection
15
USB Settings and Connection
16
LAN Settings and Connection
17
LAN Settings and Connection
22
Remote Mode
23
Chapter 3 Model IM3523 Connection and Setting
25
Overview of Communication
25
USB Settings and Connection
26
USB Settings and Connection
27
GP-IB Connection and Settings (When Connected to the Z3000)
28
Connecting the GP-IB Cable
28
Setting GP-IB
28
RS-232C Connection and Settings (When Connected to the Z3001)
30
Connecting the RS-232C Cable
30
Setting RS-232C
31
LAN Settings and Connection (When Connected to the Z3002)
33
Connecting a LAN Cable
37
Remote Mode
38
Chapter 4 Model IM3533/ IM3533-01/ IM3590 Connection and Setting
39
Overview of Communication
39
USB Settings and Connection
41
USB Settings and Connection
42
GP-IB Connection and Settings (When Connected to the Z3000)
43
Connecting the GP-IB Cable
43
Setting GP-IB
43
RS-232C Connection and Settings (When Connected to the Z3001)
45
Connecting the RS-232C Cable
45
Setting RS-232C
46
LAN Settings and Connection (When Connected to the Z3002)
47
LAN Settings
47
Connecting a LAN Cable
52
Remote Mode
53
Chapter 5 Model IM7580 Connection and Setting
55
Overview of Communication
55
USB Settings and Connection
57
USB Settings and Connection
58
LAN Settings and Connection
59
LAN Settings and Connection
64
GP-IB Connection and Settings (When Connected to the Z3000)
65
Connecting the GP-IB Cable
65
Setting GP-IB
65
RS-232C Connection and Settings (When Connected to the Z3001)
67
Connecting the RS-232C Cable
67
Setting RS-232C
68
Remote Mode
69
Appendix
71
Appendix 1 Checking the USB Virtual COM Port
71
Advertisement
Hioki IM3536 Instruction Manual (76 pages)
LCR METER, IMPEDANCE ANALYZER
Brand:
Hioki
| Category:
Measuring Instruments
| Size: 3 MB
Table of Contents
Table of Contents
3
Introduction
5
Safety Information
5
Chapter 1 Specifications
7
RS-232C Specifications
7
GP-IB Specifications
8
USB Specifications
8
LAN Specifications
8
Chapter 2 Model IM3570/ IM3536 Connection and Setting
9
Overview of Communication
9
RS-232C Connection and Settings
12
GP-IB Connection and Settings
13
USB Settings and Connection
15
Setting USB
15
Connecting the USB Cable
16
LAN Settings and Connection
17
LAN Settings
17
LAN Settings
18
Connecting a LAN Cable
22
Remote Mode
23
Chapter 3 Model IM3523/ IM3523A Connection and Setting
25
Overview of Communication
25
USB Settings and Connection
27
Connecting the USB Cable
28
GP-IB Connection and Settings (IM3523 Only, When Connected to the Z3000)
29
Connecting the GP-IB Cable
29
RS-232C Connection and Settings (IM3523 Only, When Connected to the Z3001)
31
Connecting the RS-232C Cable
31
Setting RS-232C
32
LAN Settings and Connection (IM3523 Needs to be Connected to the Z3002)
34
LAN Settings
34
Connecting a LAN Cable
37
Remote Mode
38
Chapter 4 Model IM3533/ IM3533-01/ IM3590 Connection and Setting
39
Overview of Communication
39
USB Settings and Connection
41
USB Settings and Connection
42
GP-IB Connection and Settings (When Connected to the Z3000)
43
Connecting the GP-IB Cable
43
Setting GP-IB
43
RS-232C Connection and Settings (When Connected to the Z3001)
45
Connecting the RS-232C Cable
45
Setting RS-232C
46
LAN Settings and Connection (When Connected to the Z3002)
47
LAN Settings
47
Connecting a LAN Cable
52
Remote Mode
53
Appendix
71
Appendix 1 Checking the USB Virtual COM Port
71
Hioki IM3536 Communication Instruction Manual (66 pages)
LCR METER IMPEDANCE ANALYZER
Brand:
Hioki
| Category:
Measuring Instruments
| Size: 1 MB
Table of Contents
Table of Contents
2
Introduction
4
Safety Information
4
Chapter 1 Specifications
5
RS-232C Specifications
5
GP-IB Specifications
6
USB Specifications
6
LAN Specifications
6
Chapter 2 Model IM3570/ IM3536 Connection and Setting
7
Overview of Communication
7
RS-232C Connection and Settings
9
GP-IB Connection and Settings
11
USB Settings and Connection
13
LAN Settings and Connection
15
Remote Mode
21
Chapter 3 Model IM3523 Connection and Setting
22
Overview of Communication
22
USB Settings and Connection
23
GP-IB Connection and Settings (When Connected to the Z3000)
25
Connecting the GP-IB Cable
25
Setting GP-IB
25
RS-232C Connection and Settings (When Connected to the Z3001)
27
Connecting the RS-232C Cable
27
Setting RS-232C
28
LAN Settings and Connection (When Connected to the Z3002)
30
LAN Settings
30
Connecting a LAN Cable
34
Remote Mode
35
Chapter 4 Model IM3533/ IM3533-01/ IM3590 Connection and Setting
36
Overview of Communication
36
USB Settings and Connection
38
GP-IB Connection and Settings (When Connected to the Z3000)
40
RS-232C Connection and Settings (When Connected to the Z3001)
42
Connecting the RS-232C Cable
42
Setting RS-232C
43
LAN Settings and Connection (When Connected to the Z3002)
44
LAN Settings
44
LAN Settings
45
Connecting a LAN Cable
49
Remote Mode
50
Chapter 5 Model IM7580 Connection and Setting
51
Overview of Communication
51
USB Settings and Connection
53
LAN Settings and Connection
55
GP-IB Connection and Settings (When Connected to the Z3000)
61
Connecting the GP-IB Cable
61
Setting GP-IB
61
RS-232C Connection and Settings (When Connected to the Z3001)
63
Connecting the RS-232C Cable
63
Setting RS-232C
64
Remote Mode
65
Appendix
66
Appendix 1 Checking the USB Virtual COM Port
66
Advertisement
Related Products
Hioki IM3523
Hioki IM3533-01
Hioki IM3533
Hioki IM3570
Hioki IM3590
Hioki IM3536-01
Hioki IM3523A
Hioki IM7587-02
Hioki IM7583-01
Hioki IM7583 Series
Hioki Categories
Measuring Instruments
Test Equipment
Data Loggers
Multimeter
Accessories
More Hioki Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL