Sign In
Upload
Manuals
Brands
Hioki Manuals
Test Equipment
8807-51
Hioki 8807-51 General Equipment Test Manuals
Manuals and User Guides for Hioki 8807-51 General Equipment Test. We have
2
Hioki 8807-51 General Equipment Test manuals available for free PDF download: Instruction Manual
Hioki 8807-51 Instruction Manual (354 pages)
MEMORY HiCORDER
Brand:
Hioki
| Category:
Test Equipment
| Size: 3.67 MB
Table of Contents
Table of Contents
3
Safety Notes
14
Notes on Use
18
Chapter Summary
22
Chapter 1 Product Overview
25
Major Features
25
Identification of Controls and Indicators
27
Chapter 2 Installation and Preparation
31
Installation of the Product
31
Power Supply and Ground Connection
32
Connecting the AC Adapter
32
Installing the Batteries/Battery Pack
33
Power On/Off
35
Connecting the Connection Cord
36
Connecting the 9322 DIFFERENTIAL PROBE
37
Connecting the Logic Probe
40
Connecting the 9018-10, 9132-10 CLAMP on PROBE
41
Connecting the 8992 PRINTER UNIT
42
Loading Recoding Paper
43
Care of Recording Paper
45
Attaching the Strap
46
Notes on Measurement
47
Chapter 3 Basic Button Operation
49
Screen Display Buttons
50
Printer Buttons
50
Item Setting Buttons
51
Waveform Scrolling Buttons
51
Input Operation
52
Measurement Start and Stop
53
Other Buttons Operation
53
Key Lock Function
54
Changing the Screen
55
Chapter 4 Memory Recorder Function
57
Overview of the Memory Recorder Function
57
Operation Sequence (MEM)
58
Setting Items
60
Setting the Function Mode
60
Setting the Time Axis Range
61
Setting the Recording Length
62
Setting the Display Layout
64
Setting the Auto Save Function
66
Setting the Print Mode
69
Setting the Auto Print Function
70
Using the X-Y Waveform Plots (MEM)
71
Waveform Screen Settings (MEM)
73
Auto Range Function
74
Start and Stop Operation (MEM)
75
Extended Status Screen Setup (MEM)
76
Channel Usage Settings
77
Setting the Roll Mode
78
Sequential Save Function
79
Numerical Calculation (Measurement)
88
Chapter 5 Recorder Function
95
Overview of the Recorder Function
95
Operation Sequence (REC)
96
Setting Items
98
Setting the Function Mode
98
Setting the Time Axis Range
99
Setting the Recording Length
100
Setting the Display Layout
102
Setting the Auto Save Function
104
Setting the Print Mode
107
Setting the Printer Function
108
(Real Time Printing)
108
Setting the Display Clear Function (X-Y Only)
109
Using the X-Y CONT Recorder
110
Waveform Screen Settings (REC)
112
Start and Stop Operation (REC)
113
Chapter 6 RMS Recorder Function
115
Overview of the RMS Recorder Function
115
Operation Sequence (RMS)
116
Setting Items
118
Setting the Function Mode
118
Setting the Time Axis Range
119
Setting the Recording Length
120
Setting the Frequency
122
Setting the Display Layout
123
Setting the Auto Save Function
125
Setting the Print Mode
128
Setting the Printer Function
129
Printing)
129
Instantaneous Waveform Recording
130
Waveform Screen Settings (RMS)
135
Settings on the Channel Screen (RMS)
136
Selecting the Recorder Function or RMS Function
136
Start and Stop Operation (RMS)
137
Chapter 7 Input Channel Settings
139
Overview
139
Operation Sequence (Input Channel Setting)
140
Setting the Channel Screen
142
Setting the Waveform Display Color
142
Setting the Waveform Display Graph
143
Setting the Voltage Axis Range
144
Setting the Input Coupling
145
Setting the Magnification/Compression Ratio Along the Voltage Axis
147
Setting the Zero Position
148
Setting the Low-Pass Filter
150
Setting the Logic Inputs
151
Waveform Screen Input Settings
153
Scaling Function
154
Chapter 8 Trigger Functions
161
Overview of the Trigger Function
161
Operation Sequence (Trigger Mode Setting)
162
Trigger Mode
164
Pre-Trigger
165
Trigger Timing (REC Only)
167
Trigger Source AND/OR Linking
168
Manual Trigger
169
Internal Trigger
170
Level Trigger
171
Window-In Trigger
174
Window-Out Trigger
176
Voltage Drop Trigger
178
Waveform Detection Trigger (Memory Only)
180
Logic Trigger
184
Trigger Settings from the Waveform Screen
187
Timer Trigger Function
188
External Trigger Function
190
Trigger Output Terminal
192
Input Level Monitor Function
194
Chapter 9 Waveform Screen Operation
195
Using the A/B Cursors
196
Line Cursor (Horizontal)
197
Line Cursor (Vertical)
197
Trace Cursor
197
Using the Line Cursors (Vertical)
198
Waveform Screen
198
Using the Line Cursors (Horizontal)
199
Using the Trace Cursors
200
Using the Cursors on the X-Y Screen
201
Scrolling the Waveform
202
Magnification/Compression Ratio Along the Time Axis
203
DMM Function
204
Setting the Waveform Display Area
207
Chapter 10 System Settings
209
Environment Screen (SYSTEM)
210
START Button Activation
210
Start Backup
211
Grid Type
212
Time Value
213
Logic Recording Width
214
Backlight Saver
215
Backlight Brightness
216
Display Color
217
Language
218
Printer
219
Comment Screen (SYSTEM)
220
RS© Screen (SYSTEM)
221
Screen Copy Output Destination
221
RS-232C Settings
223
Setting Screen
224
Initialize Screen
226
Setting the Clock
226
Clearing the Waveform Data
227
System Reset
228
Self-Check
229
Chapter 11 Printout of Measurement Data
231
Printout of Measurement Data Operating Procedure
232
Environment Screen (Printer)
234
Grid Type
234
Time Value
235
List&Gauge
236
Channel Marker
237
Printer Density
238
Comment Screen (Printer)
239
Title Comment Entry
239
Analog and Logic Comment Entry
241
Text Entry Procedure
244
Setting the Status Screen (Printout)
247
Setting the Channel Screen (Printout)
248
Printing Procedure
249
Manual Print
249
Auto Print (MEM)
250
Real Time Print (REC, RMS)
251
Partial Print
252
Screen Copy
253
List Print
253
Report Print
254
Example of Printer Output
255
Chapter 12 Storing the Measurement Data
259
PC Card
260
Using the PC Card Slot
262
Settings on the File Screen
264
Loading the Data
264
Saving Measurement and Setting Data
267
Deleting the Files and Directories
275
Creating the Directory
277
Initializing
280
Changing the Names of Files and Directories
281
Settings on the File Configuration Screen (Application Functions)
283
Sorting Files
283
Self-Check
285
Text File Internal Format
286
Chapter 13 Communication Function
289
Connecting the RS-232C Cable
290
Setting the RS-232C Interface
291
Chapter 14 Specifications
293
General Specifications
293
Trigger
297
Harmonic Wave Trigger
298
Memory Recorder Function
299
Recorder Function
300
RMS Recorder Function
301
Harmonic Wave Analysis Function
302
General Specifications
302
Instantaneous Analysis Functions
303
Time Series Analysis Functions
304
Additional Functions
306
Communication Function
307
Others
308
Chapter 15 Logic and Analog Inputs
311
Logic Inputs
311
Advertisement
Hioki 8807-51 Instruction Manual (76 pages)
MEMORY HiCORDER
Brand:
Hioki
| Category:
Test Equipment
| Size: 3.05 MB
Table of Contents
Table of Contents
3
1 General Description
5
2 Setup Procedures
6
3 Basic Setting Items
7
Function Setting
7
Measurement Target Setting
7
4 Analog Input Channel Setting
9
Waveform Display Color Setting
9
Input Type Setting
10
Vertical Axis Range Setting
11
Scaling Setting
12
Scale Conversion Rate Setting
13
Line Connection & Level Check
15
DMM Function
17
5 Instantaneous Analysis Mode
19
Analyses and Display Screens
19
Basic Item Setting
25
Cursor Operation
31
Analysis Example 1: Simultaneous Instantaneous Analysis of Two 100-VAC Single-Phase 2-Wire Lines
32
Line Connection & Level Check Setting
33
Analysis Example 2: Instantaneous Analysis of 200-VAC 3-Phase 3-Wire Line
37
6 Time-Series Analysis Mode
39
Basic Item Setting
39
Analysis Item Setting
45
Cursor Operations
49
Waveform Scrolling
50
Input Setting in Waveform Display Screen
51
Over-Range Check Function
52
Analysis Example: Time-Series Analysis of 100-VAC Single-Phase 3-Wire Line
53
On Probe
53
7 Triggers for Harmonic Wave Analysis Function
56
Basic Trigger Setting Items and Setting Methods
56
Harmonic Wave Trigger
59
Advertisement
Related Products
Hioki 8808-51
Hioki 8807-01
Hioki 8808-01
Hioki 8860-50
Hioki 8861-50
Hioki MEMORY HiCORDER 8855
Hioki 8804
Hioki 8860
Hioki 8870-20
Hioki 8842
Hioki Categories
Measuring Instruments
Test Equipment
Data Loggers
Multimeter
Accessories
More Hioki Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL