Sign In
Upload
Manuals
Brands
heat-timer Manuals
Control Systems
SQ-Elite-EXt
heat-timer SQ-Elite-EXt Manuals
Manuals and User Guides for heat-timer SQ-Elite-EXt. We have
4
heat-timer SQ-Elite-EXt manuals available for free PDF download: Installation And Operation Manual, Installation And Operation Instruction Manual
heat-timer SQ-Elite-EXt Installation And Operation Manual (65 pages)
HYDRONIC SEQUENCING CONTROL
Brand:
heat-timer
| Category:
Controller
| Size: 7 MB
Table of Contents
Table of Contents
3
Layout
4
Overview
5
Understanding Operation Concept
7
Reset Ratio/Outdoor Reset
7
Pid Operation
8
Oss Operation
8
Initial Setup
9
Selecting the System Features
9
Installation
11
Mounting the Enclosure
11
Install the Sensors
12
Locating the System Sensor
12
Immersion Heating System Sensor (Hss) Installation
12
Strap-On Heating System Sensor (Hss) Installation
12
Outdoor Sensor Installation
13
Wiring
14
Wiring the Power
14
Wiring the Sensors
14
Wiring the Domestic Hot Water (Dhw) Sensor
15
Wiring the Shutdown
15
Wiring the T-Stat
16
Wiring the Setback
16
Wiring the Prove
16
Wiring the System Output
17
Wiring the Dhw Pump
17
Wiring the Combustion Air Damper
17
Wiring the Stages
18
Wiring the Pump or Valve Outputs
18
Connecting to the Sq-Elite-Ext Panels
19
Connecting Sq-Elite to Two Extension
19
Selecting the Sq-Elite-Ext Panel Letter
19
Connecting 4-20Ma Ems Interface
20
Connecting to Bacnet Interface Module
21
Display
22
Installer Menu Sequence
24
Accessing the Installer Menu
24
Startup Settings
25
Startup Sequence
28
Control Mode
28
Display Unit
28
Setting the 4Ma and 20Ma Set Points
29
Application
29
Dhw Piping
29
Dhw Pump Output
30
Combustion Air Damper Output
30
External Input Mode
30
Burner Type
30
Boiler Output
31
Total Boilers
31
Staging
31
Sequence
31
Control Logic
32
Sensor Fault
32
Operating Settings
33
Season
33
Reset Ratio
34
Customized Reset Ratio
34
Set Point
35
Outdoor Cutoff Temperature
35
Target Offset
36
Minimum Target
36
Maximum Target
36
Boiler Minimum Return
37
Minimum Return
37
Return Lag
37
System Settings
37
Stage Settings
38
Reaction Time
38
Purge Delay
38
Minimum Runtime
38
Standby Delay
39
Last Stage Hold
39
Throttle Range
40
Lead Settings
41
Lead Boiler
41
Rotate Mode
41
Setback Schedule
42
Setback
42
Boost
42
Boost Period
42
Day/Night Schedules
43
Set Present Time
43
Dhw Settings
44
Dhw Priority Timer
44
Dhw Set Point
45
Dhw Differential
45
Pump, Valve, and Combustion Air Damper Operation
46
Run-On
46
Pump Exercise
46
Maintenance
47
System & Outdoor Sensor Trim
47
History
47
Configuration
47
Boiler/C.unit Setting
48
Mode
48
Runtime
48
User Menu Sequence
49
Season
49
Set Point
50
Reset Ratio
50
Customized Reset Ratio
51
Outdoor Cutoff Temperature
51
Setback
52
Day/Night Schedules
52
Pumps Piping/Wiring Diagrams
53
Multiple Boilers with Pumps Piping/Wiring Diagrams
53
Troubleshooting
54
Temperature Inputs
54
Control Operation
55
Bacnet
56
Bacnet Mstp Startup Menu
56
Bacnet Mode
56
Bacnet Baud Rate
56
Ms/Tp Address
56
Bacnet ID
56
Elite Series Bacnet Pics Statement
57
Sq 8T-Bacnet Variable List
58
Specifications
61
Notes
62
Warranty
64
Advertisement
heat-timer SQ-Elite-EXt Installation And Operation Instruction Manual (44 pages)
HydronIc BoIler seQuencIng wItH MotorIzed ValVe control
Brand:
heat-timer
| Category:
Control Systems
| Size: 1 MB
Table of Contents
Table of Contents
2
Sq-Elite-MV Layout
3
Sq-Elite-MV Overview
4
Understanding Operation Concept
5
Reset Ratio/Outdoor Reset
5
Make Sure You Have the Right Control
6
Initial Setup
6
Selecting the System Features
6
Installation
7
Mounting the Enclosure
7
Install the Sensors
8
System and Return Sensors Installation
8
Outdoor Sensor Installation
8
Wiring Inputs
9
Wiring the Power
9
Wiring the Sensors
9
Wiring the Domestic Hot Water Input
10
Wiring the Shutdown
10
Wiring the SEQ Tstat
10
Wiring the SEQ Setback
10
Wiring Outputs
11
Wiring the System Pumps
11
Wiring the DHW Pump
11
Wiring the Stages
12
Wiring the Motorized Valve
12
Connecting to the SQ-Elite-EXT Panels and 4-20Ma EMS Interface
12
Selecting the SQ-Elite-EXT Panel Letter
12
Startup Settings
13
Program Change Settings
13
Startup Sequence
13
Installer Menu Sequence
14
SEQ Control Mode
18
MOV Control Mode
18
Display Unit
18
Setting the 4Ma and 20Ma SEQ Set Points
18
DHW Piping
18
DHW Pump Output
19
External Input 1 Mode
19
External Input 2 Mode
19
Burner Type
19
Boiler Output
19
Total Boilers
19
Sequence
20
Control Logic
20
SEQ Sensor Fault
20
MOV Sensor Fault
21
Setting the Control to Factory Defaults
21
Operating Settings
22
Program Change Settings
22
Season
22
Seq and Mov Reset Ratio Settings
22
SEQ and MOV Reset Ratio
22
SEQ and MOV Customized Reset Ratio
22
SEQ and MOV Target Offset
23
SEQ and MOV Outdoor Cutoff
23
SEQ and MOV Minimum Target
24
SEQ and MOV Maximum Target
24
Seq and Mov Set Point Settings
24
Boiler Minimum Return
24
Minimum Return
24
Return Lag
24
Seq Settings
25
Seq Stage Settings
25
Reaction Time
25
Purge Delay
25
Minimum Runtime
25
Standby Delay
25
Last Stage Hold
26
Throttle
26
Lead Settings
27
Lead Boiler
27
Rotate Mode
27
Mov Settings
27
Gain
27
Setback Schedule
28
SEQ and MOV Setback
28
SEQ and MOV Boost
28
SEQ and MOV Boost Period
28
SEQ and MOV Day/Night Schedules
28
Set Present Time
28
Dhw Settings
29
DHW Priority Timer
29
Pump and Valve Operation
29
SEQ and MOV Run-On
29
SEQ and MOV Pump Exercise
29
Maintenance
30
Valve
30
Systems, Outdoor, or Return Sensor Trim
30
History
30
Configuration
30
Display and Buttons
30
Stage Settings
32
Mode
32
Runtime
32
Troubleshooting
33
Mechanical and Electrical Diagrams
36
User Menu Sequence
40
User Settings
41
Program Change Settings
41
Season
41
Seq and Mov Reset Ratio Settings
41
SEQ and MOV Reset Ratio
41
SEQ and MOV Customized Reset Ratio
42
SEQ and MOV Target Offset
42
SEQ and MOV Outdoor Cutoff
42
Setback Schedule
43
SEQ and MOV Setback
43
SEQ and MOV Day/Night Schedules
43
Specifications
44
heat-timer SQ-Elite-EXt Installation And Operation Instruction Manual (40 pages)
Brand:
heat-timer
| Category:
Control Systems
| Size: 1 MB
Table of Contents
Table of Contents
2
Sq-Elite-8T Layout
3
Sq-Elite-8T Overview
4
Understanding Operation Concept
5
Reset Ratio/Outdoor Reset
5
PID Operation
6
OSS Operation
6
Make Sure You Have the Right Control
7
Initial Setup
7
Selecting the System Features
7
Installation
8
Mounting the Enclosure
8
Install the Sensors
9
System Sensor Installation
9
Outdoor Sensor Installation
9
Wiring
10
Wiring the Power (Terminals 1, 2)
10
Wiring the Sensors
10
Wiring the Domestic Hot Water (DHW) Sensor (Terminals 33, 34)
11
Wiring the Shutdown (Terminals 35, 36)
11
Wiring the T-STAT (Terminals 35, 36)
11
Wiring the Setback (Terminals 35, 36)
11
Wiring the Prove (Terminals 37, 38)
11
Wiring the System Output (Terminals 19, 20)
12
Wiring the DHW Pump (Terminals 21, 22)
12
Wiring the Combustion Air Damper (Terminals 23, 24)
12
Wiring the Stages (Terminals 3 to 17)
12
Connecting to the SQ-Elite-EXT Panels and 4-20Ma EMS Interface
13
Selecting the SQ-Elite-EXT Panel Letter
13
Installer Menu Sequence
14
Startup Settings
17
Program Change Settings
17
Startup Sequence
17
Control Mode
17
Display Unit
17
Setting the 4Ma and 20Ma Set Points (Available in 4-20Ma EMS Only)
17
Application
18
DHW Piping (Available with Heating Only)
18
DHW Pump Output
18
Combustion Air Damper Output
18
External Input Mode
18
Burner Type
19
Boiler Output
19
Total Boilers
19
Staging
19
Sequence
19
Control Logic
20
Sensor Fault
20
Setting the Control to Factory Defaults
20
Operating Settings
21
Program Change Settings
21
Season
21
Reset Ratio
21
Customized Reset Ratio
21
Set Point (Not Adjustable in EMS Mode)
22
Outdoor Cutoff Temperature
22
Target Offset
22
Minimum Target
23
Maximum Target
23
Boiler Minimum Return
23
Minimum Return
23
Return Lag
24
System Settings
24
Program Change Settings
24
Stage Settings
24
Reaction Time
24
Purge Delay
24
Minimum Runtime
24
Standby Delay
25
Last Stage Hold
25
Throttle Range
25
Lead Settings
26
Lead Boiler
26
Rotate Mode
26
Setback Schedule
26
Setback
26
Boost
27
Boost Period
27
Day/Night Schedules
27
Set Present Time
28
DHW Settings
28
DHW Priority Timer (Available with Parallel DHW Piping)
28
DHW Set Point (Requires an Optional DHW Temperature Sensor)
28
Pump, Valve, and Combustion Air Damper Operation
29
Run-On
29
Pump Exercise
29
Maintenance
30
System & Outdoor Sensor Trim
30
History
30
Configuration
30
Display and Buttons
30
Boiler/C.unit Settings
32
Mode
32
Runtime
32
Troubleshooting
33
Multiple Boilers with Pumps Piping/Wiring DIAGRAMS
34
User Menu Sequence
35
Program Change Settings
35
Season
35
Set Point (Not Adjustable in EMS Mode)
36
Reset Ratio
36
Customized Reset Ratio
36
Outdoor Cutoff Temperature
37
Setback
37
Day/Night Schedules
37
Specifications
40
Advertisement
heat-timer SQ-Elite-EXt Installation And Operation Instruction Manual (28 pages)
steam seqSuencIng control
Brand:
heat-timer
| Category:
Control Systems
| Size: 1 MB
Table of Contents
Table of Contents
2
Sq-Elite-8S Layout
3
Sq-Elite-8S Overview
4
Understanding Operation Concept
5
PID Operation
5
OSS Operation
5
Initial Setup
6
Selecting the System Features
6
Installation
7
Mounting the Enclosure
7
Install the Sensors
8
System Pressure Sensor Installation
8
Outdoor Sensor Installation
8
Wiring
9
Wiring the Power (Terminals 1, 2)
9
Wiring the Inputs
9
System Pressure Sensor Wiring (Terminals 25, 26)
9
Outdoor Sensor Wiring (Terminals 29, 30)
9
Wiring the Shutdown (Terminals 35, 36)
9
Wiring the T-STAT (Terminals 35, 36)
10
Wiring the Setback (Terminals 35, 36)
10
Wiring the Prove (Terminals 37, 38)
10
Wiring the Outputs
10
Wiring the System Output (Terminals 19, 20)
10
Wiring the Combustion Air Damper (Terminals 23, 24)
10
Wiring the Stages (Terminals 3 to 17)
11
Connecting to the SQ-Elite-EXT Panels and 4-20Ma EMS Interface
11
Selecting the SQ-Elite-EXT Panel Letter
11
Installer Menu Sequence
12
Startup Settings
14
Program Change Settings
14
Startup Sequence
14
Control Mode
14
Sensor Type
14
Display Standard
14
Setting the 4Ma and 20Ma Set Points (Available in 4-20Ma EMS Only)
14
Combustion Air Damper Output
15
External Input Mode
15
Burner Type
15
Total Boilers
15
Staging
15
Sequence
16
Control Logic
16
Sensor Fault
16
Setting the Control to Factory Defaults
16
Operating Settings
17
Program Change Settings
17
Season
17
Set Point (Not Adjustable in EMS Mode)
17
Outdoor Cutoff Temperature
17
System Settings
17
Program Change Settings
18
Stage Settings
18
Reaction Time
18
Purge Delay
18
Minimum Runtime
18
Standby Delay
18
Last Stage Hold
19
Lead Settings
19
Lead Boiler
20
Rotate Mode
20
Setback Schedule
20
Setback
20
Day/Night Schedules
21
Set Present Time
21
Combustion Air Damper Operation
21
Run-On
21
System Exercise
21
Maintenance
21
System & Outdoor Sensor Trim
22
History
22
Configuration
22
Display
22
Boiler Settings
23
Mode
23
Runtime
24
Pressure Transducer Default Settings and Ranges
24
Troubleshooting
25
User Menu Sequence
26
Program Change Settings
26
Season
26
Set Point (Not Adjustable in EMS Mode)
27
Outdoor Cutoff Temperature
27
Setback
27
Day/Night Schedules
27
Specifications
28
Advertisement
Related Products
heat-timer SQ-Elite-8S
heat-timer SQ-Elite-MV
heat-timer SQ-Elite-8T
heat-timer SMC
heat-timer DIGI-Elite SEQ-3
heat-timer DHW Energy Saver
heat-timer Categories
Control Systems
Control Unit
Controller
Control Panel
Security Sensors
More heat-timer Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL