Sign In
Upload
Manuals
Brands
Halma Manuals
Security Sensors
Ampac FastSense PLUS
Halma Ampac FastSense PLUS Manuals
Manuals and User Guides for Halma Ampac FastSense PLUS. We have
1
Halma Ampac FastSense PLUS manual available for free PDF download: Installation & Operation Manual
Halma Ampac FastSense PLUS Installation & Operation Manual (79 pages)
High Sensitivity Detector
Brand:
Halma
| Category:
Security Sensors
| Size: 2.69 MB
Table of Contents
Table of Contents
2
Introduction
5
Types of Detectors
6
Standard Detector
6
Stand Alone Command Module/ Command Module Detector
6
Standard Detector Interior View
7
Stand-Alone Command Module Interior View
8
Command Module Detector Interior View
9
Controls and Indicators
10
Types of Display
11
Programming the Unit
12
Engineering Access Code
12
Overview of Programming Functions
13
Data Entry
13
Applicability
13
Programming a Detector from a Command Module
14
Remote Functions
14
List of Programmable Functions
15
Time and Date ( All, Numeric )
16
Fire Alarm Levels (Detector, Numeric)
17
Fire Alarm Time Delays (Detector Numeric)
18
Classifire Override (Detector, Numeric)
18
Classifire Alarm Factor
19
Hours of Day/Night (Active/Inactive) Operation (Detector, Numeric)
20
Laser Dust Discrimination (Detector Yes / No)
20
Initiate Fastlearn (Detector Yes / No)
20
Automatic Fastlearn on Power up (Detector, Yes / No)
21
Fire Alarm Time Delay Override ( Detector, Yes / no )
21
Cascading Alarms (Detector Yes / No)
21
Latching Alarm Relays (Any, Yes / No)
21
Latching Fault Relays (Any, Yes / No)
21
Remote Day / Night Switching ( Detector, Yes / no )
22
Remote Detector Reset (Any, Yes / No)
22
Remote Isolate (Any, Yes / No)
22
Programmed Isolate (Any, Yes / No)
23
Number of Detectors (CM, Entry / Display)
23
Device Text (Any, Alphanumeric)
23
Reference Detector Enable ( Detector, Yes / no )
24
Reference Detector Address ( Detector, Numeric )
24
Reference Desensitisation Factor ( Detector, Numeric )
24
Reference Desensitisation Delay (Detector, Numeric)
25
Front Panel Buttons (LCD, Yes / No)
25
Power Saving Mode (Detector, Yes / No)
26
Power Supply Battery Fault Detection (Any, Yes / No)
26
Power Supply Mains Fault Detection (Any, Yes / No)
26
Aspirator Speed (Detector, Numeric)
27
Airflow Fault Threshold (Detector, Yes / No)
27
Enable / Disable Airflow Sensors ( Detector, Yes / no )
27
Airflow Rate ( Detector, Yes / no )
27
Airflow Thresholds (Detector Numeric)
27
Detector Chart Log Recording Rate ( All, Numeric )
29
User Defined Function Access Code ( LCD< Numeric )
30
Building Management System (BMS) Protocol ( CM Numeric )
30
Detector Factory Default Settings ( All, Yes / no )
30
Command Module Scan for Detectors (CM, Yes / NO)
31
Fault - Tolerant Communication Bus ( CM, Yes / no )
32
Command Module Communication Poll Time out ( CM, Numeric )
32
Command Module Pager / GSM Phone Functions ( CM, Various )
32
View Event Log (All, Entry)
33
Detector Diagnostic Tests (Detector , Entry)
33
Detector Output / Flow Readings ( Detector, Entry )
33
Communication Loop Errors ( LCD, Entry )
34
Dust Separator Filter Condition ( Detector, Entry )
34
Fire and Fault Relay Tests ( Any, Entry )
34
Watchdog Interrupt Count ( LCD, Entry )
34
Detector Command Module Reset (All, Entry)
35
Detector / Command Module Isolate from Fire Panel ( All, Entry )
35
Exiting Programming Mode ( LCD, Entry )
36
4.3.51 Menu Map
37
4.3.52 Error Messages
42
4.3.53 Menu Map Summary
44
Sampling Pipe Design
46
Pipework
46
Installation
47
General
47
Mechanical Installation
47
Sampling Pipes
49
Pipe Reducing Bungs
49
Removal and Replacement of the Detector Front Cover
50
Electrical Installation
51
Detector Terminal Block Connections
51
Command Module Terminal Block Connections
52
Connecting Power Cables
53
Power Supply Connections
53
External Power Supply
54
Backup Batteries
55
Demonstration Mode
55
External Communication
56
BMS Protocols on the Fastsense PLUS Command Module
56
Text Output Support (Protocol 1)
56
Bacnet Support (Protocol 2)
56
Paging from the Command Module
57
Configuring the Software
57
Event Log
58
Interfacing
59
Setting the Detector Address
59
Address Table
60
Connecting a Detector Network to a Command Module
61
Fault Tolerant Detector Loop Configuration
61
Non-Fault Tolerant Serial Configuration
61
Connecting a Command Module to an Addressable Fire Panel
62
Connecting a Single Fastsense PLUS to an Addressable Fire Panel
63
Connecting to a PC
63
Commissioning
64
Commissioning Checklist
64
11 Maintenance
65
Optional Extras
68
Addressable Protocol Interface Card (Apic's)
68
Input / Relay Card
72
Trouble Shooting
73
Pressing RESET or ISOL. Button Has no Effect
73
Nuisance Alarms Occur too Often
73
Elevated Smoke Levels Do Not Generate Alarms
73
Low Mean Output
73
Detector Sensitivity Varies over Time
73
Flow Fault Errors
73
13.6.1 "Low Flow" Error Messages
74
13.6.2 "High Flow" Error Messages
74
Cannot Refit the
74
No Display
74
The Event Log and Fastlearn
74
Garbled Characters on the LCD
75
Error Messages
76
Do's and Don'ts
77
Fastsense PLUS Specification
78
Advertisement
Advertisement
Related Products
Halma Ampac TITANUS MICRO-SENS
Halma Ampac ZoneSense Plus
Halma Ampac XPander
Halma Ampac TITANUS PRO-SENS
Halma Ampac TITANUS PRO-SENS-SL
Halma Ampac LoopSense
Halma Ampac FireFinder
Halma Ampac EvacUElite
Halma ALICAT LCS Series
Halma ALICAT IMC
Halma Categories
Controller
Measuring Instruments
Security Sensors
Accessories
Control Panel
More Halma Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL