Table of Contents
About this Document
2
Application Product
2
Revision History
3
Safety Information
4
Table of Contents
5
1 Introduction
10
Scope
10
Audience
10
Document Organization
10
2 Introduction to at Commands
11
AT Command Syntax
11
String Type Parameters
11
Command Lines
11
Information Responses and Result Codes
12
Command Response Time-Out
12
Command Issuing Timing
13
Setting Commands Saving
13
AT Commands References
14
ATI Request Identification Information
16
AT+GMI Request Manufacturer Identification
16
AT+CGMI Request Manufacturer Identification
16
AT+GMM Request Model Identification
17
AT+CGMM Request Model Identification
17
AT+GMR Request Revision Identification
17
AT+CGMR Request Revision Identification
18
AT+GSN Request IMEI
18
AT+CGSN Request IMEI
19
AT+CIMI Request International Mobile Subscriber Identity
19
AT+ZGETICCID Get the ICCID of (U)SIM
19
AT+ZPCB Check PCB no
20
3 General Commands
21
ATS5 Command Line Editing Character
21
AT&F Set to Factory-Defined Configuration
21
AT&V Display Current Configuration
22
AT&W Store at Command Setting to User Defined Profile
22
ATZ Reset to Default Configuration
22
ATO Return to Online Data State
23
ATQ Result Code Suppression
23
ATE Command Echo
24
ATV DCE Response Format
24
AT+CFUN Set Phone Functionality
25
AT+CSCS Select te Character Set
26
AT+CMEE Report Mobile Termination Error
26
CME ERROR ME Error Result Code
27
4 Serial Interface Control Commands
30
AT&C Circuit 109 (Received Line Signal Detector) Behaviour
30
AT&D Circuit 108 (Data Terminal Ready) Behaviour
30
AT&S Set Data Set Ready (DSR) Line Mode
31
AT+IFC DTE-DCE Local Flow Control(Not Support Yet)
31
AT+IPR Fixed DTE Rate
32
AT+ZUFLOW 4-Wires UART Flow Control Command
33
AT+CMUX Enable CMUX
33
5 SIM Related Commands
34
AT+CLCK Facility Lock
34
AT+CPWD Change Password
35
AT+CPIN Enter PIN
36
AT+CRSM Restricted SIM Access
37
AT+CNUM Subscriber Number
38
AT+ZPINPUK Check PIN and PUK Retry Times
39
6 SMS Commands
40
AT+CSMS Select Message Service
40
AT+CMGF Message Format
41
AT+CSCA Service Centre Address
42
AT+CSMP Set Text Mode Parameters
42
AT+CSCB Select Cell Broadcast Message Types (Not Support Yet)
44
AT+CSAS Save Settings
44
AT+CRES Restore Settings
45
AT+CNMI New Message Indications to te
45
AT+CMGL List Messages
47
AT+CMGR Read Message
48
AT+CMGS Send Message
50
AT+CMSS Send Message from Storage
51
AT+CMGW Write Message to Memory
51
AT+CMGD Delete Message
52
AT+CMGC Send Command
53
AT+CMMS more Messages to Send
53
AT+CPMS Preferred Message Storage
54
CMTI New Message Indications
55
AT+ZSPWAKEUP Enable/Disable Specified SMS Remote Wakeup Function
56
AT+ZWAKEUPSMS Set the Specified SMS Content Used for Remote Wakeup
56
CMS ERROR Message Service Failure Result Code
57
7 Network Service Commands
59
AT+CREG Network Registration
59
AT+CEREG Network Registration
60
AT+COPS Operator Selection
61
AT+CSQ Signal Quality
62
AT+CPOL Preferred Operator List
63
AT+COPN Read Operator Names
65
AT+CTZU Automatic Time Zone Update
66
AT+CTZR Time Zone Reporting
66
AT+ZCELLINFO Request the Information about Serving Cell
67
AT+ZLOCKCELL Lock Cell Command
68
AT+ZSNT Configuration of Network Selection Mode
70
AT+ZSNTE Network Selection According to 2G/3G/4G
71
AT+ZPAS Check Module Status
72
AT^SYSINFO Request System INFO
72
AT+ZBAND Band Lock
74
AT+ZARFCN Return Current ARFCN
76
AT+ZCDS -Query Serving Cell Information
77
AT+ZSRSP Query RSRP,RSRQ,SINR of the Main Cell
78
AT+ZRSP Query RSRP,RSRQ,SINR of LTE Neighbour Cell
79
AT+CGEQOS Define EPS Quality of Service
80
AT+ZMONI Get the Information of Main& Neighbor Cells
81
8 Packet Domain Commands
85
AT+CGDCONT Define PDP Context
85
AT+CGATT PS Attach or Detach
86
AT+CGACT PDP Context Activate or Deactivate
87
AT+CGPADDR Show PDP Address
87
AT+CGEREP Packet Domain Event Reporting
88
AT+CGSMS Select Service for MO SMS Messages
89
AT$QCPDPP Set PDP Authentication Parameters
90
AT+ZECMCALL Make ECM Data Call
91
ZECMCALL Active Report the State of Auto-Dial
92
AT+ZNVWRITE Enable Auto-Dial Function
93
AT+ZNVREAD Query the State of Auto-Dial Function
94
AT+ZSDHCPLEASE Amend DHCP LEASE TIME
95
9 GPS Relative Commands
96
AT+ZGINIT Initialization Location Command
96
AT+ZGMODE Set Location Mode
96
AT+ZGFIXRATE Set Location Mode Choice When Reset GPS
96
AT+ZGQOS Set QOS for Location
97
AT+ZGURL Set URL of SUPL Server
98
AT+ZGRUN Location Mode Choice
98
ZGPSERROR Report Error Code
99
AT+ZGRST Reset GPS
99
AT+ZGPSAPN Set AGPS APN
100
AT+ZGPORT Set GPS Information Report Port
101
ZGMEASURE Report Satellites Measurements
102
ZGPSR Report Location Data
103
AT+ZGPSR Enable/Disable +ZGPSR Report
104
ZGPSEVENT Report Location Status Event
105
AT+ZGNMEA Set the Reported NMEA Format of GPS Data
106
Syntax of NMEA
109
Standard NMEA Output Sentence
110
GGA Sentence
110
GSA Sentence
111
GSV Sentence
112
RMC Sentence
113
VTG Sentence
113
10 Hardware Relative Commands
115
AT+CCLK Clock Management
115
AT+ZTURNOFF Turn off the Modem
115
AT+ZRST RESET the Module
115
AT+ZGPIO GPIO Pins Set Command
116
At+Zadcx Read Pin Adcx Value
118
AT+ZSWITCH Switch the Port of Module in Different Operation Systems
118
AT+ZADB Open/Close ADB Port
119
AT+ZADSET Port Switch between RNDIS/NDIS in Windows System
120
AT+ZSDT Enable SIM Card Hot-Plug Function
122
AT+ZCHIPTEMP Get the Temperature of Pmic, Xo, Pa
123
11 TCP/IP Relative Commands
124
AT+ZIPCFG Set and Query the Params of PS Call
124
AT+ZIPCALL Start or End PS Call
124
AT+ZIPOPEN Establish TCP/UDP Connection
125
AT+ZIPCLOSE Close TCP/UDP Connection
126
AT+ZIPSEND TCP/UDP Send Data in ASCII Format
127
ZIPRECV TCP/UDP Data Receive
127
AT+ZIPSTAT Query Socket State
128
AT+ZIPSLCFG Set Parameters of TCP/UDP Server
128
AT+ZIPLISTEN Open/Close TCP/UDP Server
129
AT+ZIPFRWL Set TCP/UDP Internal Firewall
130
AT+ZIPSETRPT Set the Format of Received Data
131
AT+ZIPSENDRAW Send Raw Data
132
AT+ZIPCREATE Data Transparent Transfer
133
AT+ZDNSGETIP Domain Name Resolution
133
AT+ZIPCONTEXT Switch PDP Context
134
12 FTP Relative Commands
136
AT$ZPDPACT Activate/Deactivate PDP Connection
136
AT$ZFTPCFG FTP Parameters Configuration
136
AT$ZFTPSIZE Get the Size of FTP File
137
AT$ZFTPGET File Download
137
AT$ZFTPPUT File Upload
138
AT$ZFTPCLOSE Close FTP Service
139
FTP Example
139
13 HTTP Relative Commands
141
AT+ZHTTPURL Set URL of HTTP Server
141
AT+ZHTTPGET Send GET Request to HTTP Server
141
AT+ZHTTPPOST Send POST Request to HTTP Server
141
14 Extended Commands
143
AT+ZCLRACQ Clear the Historical Earfcn/Uarfcn
143
Advertisement
Advertisement
Related Products
GOSUNCN ME3630 Series
GOSUNCN ME3630-E
GOSUNCN ME3630-J
GOSUNCN ME3630-A
GOSUNCN ME3630 mini-PCIE
GOSUNCN WeLink ME3616
GOSUNCN GM500-U1G A
GOSUNCN Categories
Control Unit
GSM/GPRS Modules
Network Router
GPS
Microphone system
More GOSUNCN Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL