Erbe VIO 200 D Electrosurgical Unit Manuals
Manuals and User Guides for Erbe VIO 200 D Electrosurgical Unit. We have
6
Erbe VIO 200 D Electrosurgical Unit manuals available for free PDF download: User Manual, Service Manual, Quick Manual
Erbe VIO 200 D User Manual (152 pages)
Brand:
Erbe
| Category:
Medical Equipment
| Size: 9 MB
Table of Contents
Table of Contents
5
1 Safety Instructions
9
Intended Use
9
Combination with Other Equipment
9
Safety Notations
9
Meaning of the Note
9
Who Must Read this User Manual
10
Compliance with Safety Information
10
Structure of Safety Instructions
10
Operating Errors and Incorrect Installation by Persons Without Training
10
Risks Due to the Environment
11
Electric Shock
12
Fire / Explosion
13
Burns
14
Inadvertent Tissue Damage
18
Risks Due to Incorrect Use of the Return Electrode
19
Defective Unit
20
Interference Caused by the Unit
21
Damage to the Unit and Accessories
22
Notes
23
2 Safety Features
25
Nessy
25
How Do I Receive Information about the Safety Status of the Return Electrode
26
Automatic Monitoring of Equipment Output Error
29
Automatic Monitoring of the on Time
30
Protection from Operating Errors
30
3 Accessories
33
Introduction
33
VIO 200 D Example Accessories
34
Check Compatibility of Instrument and CUT / COAG Mode with the Help of the Upmax Display
36
Check Compatibility of the Return Electrode
38
Compatible Footswitches
38
4 Description of the Controls
39
Controls on the Front Panel
39
Controls on the Back
41
5 Working with the Electrosurgical Unit: a Tutorial
43
The Tutorial and Your Electrosurgical System
43
Program
43
Adopt Program
46
Select Program
46
The Basic Concept of the Electrosurgical Unit: Focusing Attention on the Functions of a Receptacle (Focus View)
48
Changing Settings of the Basic Program
48
Setting Cut Mode
49
Setting CUT Effect
50
Selecting CUT Max. Wattage
51
Select COAG Mode, COAG Effect and COAG Power Limitation
52
Activation of CUT and COAG Modes with Footswitch
52
Activation of CUT and COAG Modes with Fingerswitch, AUTO START, AUTO STOP
54
The Focus View and Activation Concept of the Electrosurgical Unit. What Points Must I Observe
56
Nessy
56
How Do I Receive Information about the Safety Status of the Return Electrode
57
Saving the Amended Basic Program under a New Name
61
Overwriting a Program
62
Creating All Settings for a Program from Scratch
63
Deleting a Program
63
Creating Programs for Remode Function
63
Remode Change-Over with a 2-Button Handpiece
67
Calling up Setup
68
6 Description of Receptacle Hardware
71
Purchasing Further Receptacles
71
Receptacles for Different Modes and Instrument Connectors
71
Monopolar Receptacle
71
Bipolar Receptacle
72
Receptacle for Return Electrode
73
7 Monopolar Standard Modes
75
Auto Cut
75
Soft Coag
77
Swift Coag
79
Forced Coag
81
8 Bipolar Standard Modes
85
Bipolar Cut
85
Bipolar Soft Coag
87
Bipolar Forced Coag
89
9 Monopolar Optional Modes
93
Precise Cut
93
Dry Cut
95
Endo Cut Q
97
Endo Cut I
98
Precise Coag
100
10 Bipolar Optional Modes
103
Bipolar Precise Cut
103
Bipolar Precise Coag
105
11 APC Receptacle (Only Available with the APC Module)
109
APC Receptacle
109
12 APC Standard Modes (Only Available with an APC Module)
111
Forced Apc
111
Precise Apc
113
Pulsed Apc
114
Argon-Assisted AUTO CUT Mode
116
Argon-Assisted SOFT COAG Mode
118
Argon-Assisted SWIFT COAG Mode
120
Argon-Assisted FORCED COAG Mode
122
13 APC Optional Modes (Only Available with an APC Module)
125
Argon-Assisted DRY CUT Mode
125
14 Installation
129
Ambient Conditions
129
Electrical Installation
130
Install Electrosurgical Unit on Overhead Support
132
Installing the Unit on an Erbe Equipment Cart
133
15 Cleaning and Disinfection
135
Wipe Disinfection
135
Instructions for Cleaning and Disinfection
135
Safety Instructions
135
16 Status Messages, Error Messages
137
17 General Technical Data
141
18 Information on Electromagnetic Compatibility (EMC)
143
Guidelines for Avoiding, Recognizing and Rectifying Unwanted Electromagnetic
143
VIO System
143
19 Maintenance, Customer Service, Warranty, Disposal
149
Maintenance
149
Customer Service
149
Warranty
150
Disposal
150
20 Symbols
151
Advertisement
ERBE VIO 200 D Service Manual (144 pages)
Brand:
ERBE
| Category:
Medical Equipment
| Size: 6 MB
Table of Contents
Table of Contents
5
1 Safety Information
9
Classification of the Safety Information
9
Knowledge of the User Manual
9
Protection from the Risk of Electric Shock
9
Electrostatically Sensitive Components
10
Liability and Warranty
10
2 Modifications
11
3 Controls
15
Controls at the Front
15
Controls at the Rear
16
4 Technical Data
19
5 Circuit Descriptions
21
Block Diagram VIO 300 D
22
Block Diagram VIO 200 D
23
Description of the Various Assemblies
24
Line Input
24
Low Voltage Power Supply Unit (L.V. Supply)
24
Power Supply (High-Voltage Power Supply Unit)
25
HF Generator
26
CPU + Sensors
27
User Interface (Control Panel)
28
ECB (ERBE Communication Bus)
28
IIF (Instrument Interface)
29
Nessy2
30
6 Set-Up
31
General Information
31
Overview of Settings for SET-UP Level 1
31
Overview of Settings for SET-UP Level 2
32
Call up SET-UP
36
Change Settings
37
7 Test Programs
39
Call up Test Programs
39
Exit Test Programs
41
Parameter Inputs in Test Programs
41
Description of Test Programs
42
Test Program "Display Test
42
Test Program "TP Relay
43
Test Program "TP Valves (APC)
44
Test Program "TP Activation Signal
44
Test Program "TP Power Supply Unit
45
Test Program "TP Generator
46
Test Program "Burn-In Test" (Only for Production)
48
Test Program "Watchdog
48
Test Program "Checkstop
48
Test Program "Measured Values" (Only with V 1.3.X and Later)
49
8 Measurement and Adjustment
51
Measurement of the HF Power Output
51
Temperature Conditions
51
Test Equipment
51
Test Set-Up
52
Test Procedure
52
Adjustment
53
Personnel Requirements
53
Temperature Conditions
53
Test Sequence
53
Test Equipment
54
Voltage
55
Spark
56
Currents
57
9 Troubleshooting
59
ERROR List for VIO System
59
A/E-Errors
60
B-Errors
63
C-Errors
79
D-Errors
85
2,3,5,6-Errors
86
NE)-Errors
90
9-Errors
92
Testing and Measuring Equipment
93
10 Maintenance and Servicing
95
Who Is Allowed to Perform Servicing and Maintenance Work
95
What Is a Safety Check
95
How Often Does a Safety Check Have to be Performed
95
Safety Check - Step by Step
96
Safety Information
96
User Manual and Visual Inspections
97
Tests to be Conducted in Accordance with the National Specifications and Regulations
97
DC Resistance
97
Performance Tests
99
Footswitch Activation
101
Fingerswitch Activation
102
Instrument Recognition MF Receptacle
103
Automatic Start Mode
104
Automatic Stop Mode
106
Spark Monitor
107
HF Power Output CUT
109
HF Power Output COAGULATE
112
Performance Test Upgrades
114
Monitor Circuits
118
11 Spare Parts
125
VIO D with Plug-In Power Supply Module
125
VIO D with Screw-In Power Supply Module
131
Wiring
137
Wiring for HF Generator Module 30140-804
137
Wiring for HF Generator Module 30140-828
139
Circuit Boards
141
Receptacle Modules
142
Bipolar Receptacles
142
Monopolar Receptacles
142
MF Receptacle
143
Receptacles for Neutral Electrode
143
Erbe VIO 200 D Service Manual (84 pages)
Brand:
Erbe
| Category:
Medical Equipment
| Size: 1 MB
Table of Contents
Table of Contents
5
Safety Instructions
7
Meaning of the Safety Instructions
7
Meaning of the Note
7
Knowledge of the User Manual
7
Protection from the Risk of Electric Shock
8
Electrostatically Sensitive Components
10
Liability and Warranty
10
Modifications
11
From VIO Version 2.2.X
11
Hardware
11
Software
11
From VIO Version 2.3.X
11
From VIO Version 2.7.X
12
Hardware
12
Software
12
Controls
13
Controls at the Front
13
Controls at the Rear
14
Technical Data
15
Setup
17
General Information
17
Overview of Settings for Setup Level 1
17
Overview of Settings for Setup Level 2
18
Calling up Setup
22
Call up Setup Level 1
22
Call up Setup Level 2
22
Change Settings
22
Remedying Malfunctions
23
Safety Information
23
ERROR List
23
Abbreviations of Error Displays
23
A/E Errors
24
B Error
27
C Error
39
D Error
41
F Error
42
2,3,5,6 Errors
43
Ne)-F
45
Errors
46
Maintenance and Servicing
47
Who Is Allowed to Perform Servicing and Maintenance Work
47
What Is a Technical Safety Check
47
How Often Does a Technical Safety Check Have to be Performed
47
Technical Safety Check - Step by Step
48
Safety Instructions
48
Testing and Measuring Equipment
50
User Manual and Visual Inspections
51
Tests to be Conducted in Accordance with the National Specifications and Regulations
51
DC Resistance
52
Performance Tests
54
Footswitch Activation
55
Fingerswitch Activation
57
Instrument Recognition Multifunction Sockets
59
Automatic Start Mode
59
Automatic Stop Mode
61
Spark Monitor
62
HF Output Power CUT
64
HF Output Power COAGULATE
68
Performance Test Upgrades
71
Monitor Circuits
75
Bipolar Resection Adapter (VIO 300 D from V 2 .2.X Only)
81
Advertisement
Erbe VIO 200 D Service Manual (84 pages)
Brand:
Erbe
| Category:
Medical Equipment
| Size: 2 MB
Table of Contents
Table of Contents
5
1 Safety Information
7
Classification of the Safety Information
7
Knowledge of the User Manual
7
Protection from the Risk of Electric Shock
7
Electrostatically Sensitive Components
8
Liability and Warranty
8
2 Modifications
9
From VIO Version 2.2.X
9
From VIO Version 2.3.X
9
From VIO Version 2.7.X
10
From VIO Version 2.8.X
10
3 Controls
11
Controls at the Front
11
Controls at the Rear
12
4 Technical Data
13
5 Setup
15
General Information
15
Overview of Settings for Setup Level 1
15
Overview of Settings for Setup Level 2
16
Call up Setup
20
Change Settings
21
6 Remedying Malfunctions
23
Safety Information
23
ERROR List
23
Abbreviations of Error Displays
23
A/E-Errors
24
B-Errors
27
C-Errors
42
D-Errors
44
F-Errors
45
2,3,5,6-Errors
46
NE)-Errors
48
9-Errors
49
7 Maintenance and Servicing
51
Who Is Allowed to Perform Servicing and Maintenance Work
51
What Is a Technical Safety Check
51
How Often Does a Technical Safety Check Have to be Performed
51
Technical Safety Check - Step by Step
52
Safety Information
52
Testing and Measuring Equipment
53
User Manual and Visual Inspections
54
Tests to be Conducted in Accordance with the National Specifications
54
And Regulations
54
DC Resistance
55
Performance Tests
57
Footswitch Activation
58
Fingerswitch Activation
60
Instrument Recognition Multifunction Sockets
61
Automatic Start Mode
62
Automatic Stop Mode
63
Spark Monitor
64
HF Power Output CUT
66
HF Power Output COAGULATE
69
Performance Test Upgrades
71
Monitor Circuits
75
Bipolar Resection Adapter (VIO 300 D from V 2.2.X Only)
80
Erbe VIO 200 D Service Manual (84 pages)
Brand:
Erbe
| Category:
Medical Equipment
| Size: 2 MB
Table of Contents
Table of Contents
5
1 Safety Information
7
Classification of the Safety Information
7
Knowledge of the User Manual
7
Protection from the Risk of Electric Shock
7
Electrostatically Sensitive Components
8
Liability and Warranty
8
2 Modifications
9
From VIO Version 2.2.X
9
From VIO Version 2.3.X
9
3 Controls
11
Controls at the Front
11
Controls at the Rear
12
4 Technical Data
13
5 Setup
15
General Information
15
Overview of Settings for Setup Level 1
15
Overview of Settings for Setup Level 2
16
Call up Setup
20
Change Settings
21
6 Remedying Malfunctions
23
Safety Information
23
ERROR List
23
Abbreviations of Error Displays
23
A/E-Errors
24
B-Errors
27
C-Errors
40
D-Errors
42
F-Errors
43
2,3,5,6-Errors
44
NE)-Errors
46
9-Errors
47
7 Maintenance and Servicing
49
Who Is Allowed to Perform Servicing and Maintenance Work
49
What Is a Safety Check
49
How Often Does a Safety Check Have to be Performed
49
Safety Check - Step by Step
50
Safety Information
50
Testing and Measuring Equipment
51
User Manual and Visual Inspections
53
Tests to be Conducted in Accordance with the National Specifications and Regulations
53
DC Resistance
54
Performance Tests
55
Footswitch Activation
57
Fingerswitch Activation
58
Instrument Recognition MF Receptacle
59
Automatic Start Mode
60
Automatic Stop Mode
61
Spark Monitor
62
HF Power Output CUT
64
HF Power Output COAGULATE
67
Performance Test Upgrades
70
Monitor Circuits
74
Bipolar Resection Adapter (VIO 300 D from V 2.2.X Only)
81
Erbe VIO 200 D Quick Manual (2 pages)
Brand:
Erbe
| Category:
Medical Equipment
| Size: 5 MB
Table of Contents
Necessary Operating Steps
1
Switch on the Device
1
Select Program
1
Check Settings
1
Apply and Connect Return Electrode
1
Monitor Return Electrode
1
Connect Instruments
1
For APC Applications, Open Argon Bottle
1
Optional Operating Steps
2
Changing Mode
2
Changing Effect
2
Changing Power Limit
2
Selecting the Focus View of a Receptacle
2
Allocating Foot Switch or AUTO START
2
Advertisement
Related Products
Erbe VIO 300 D
erbe VIO 100 C
erbe VIO 50 C
Erbe VIO 300 S
Erbe VIO 3
Erbe VIO 200 S
Erbe VIO 50
Erbe VIRON 1
Erbe VIO 20188-300
Erbe VIO 20188-302
Erbe Categories
Medical Equipment
Cables and connectors
Adapter
Measuring Instruments
Industrial Electrical
More Erbe Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL