Sign In
Upload
Manuals
Brands
Emerson Manuals
Computer Hardware
MultiFlex CUB-II
Emerson MultiFlex CUB-II Manuals
Manuals and User Guides for Emerson MultiFlex CUB-II. We have
1
Emerson MultiFlex CUB-II manual available for free PDF download: Installation And Operation Manual
Emerson MultiFlex CUB-II Installation And Operation Manual (80 pages)
Condensing Unit Board
Brand:
Emerson
| Category:
Computer Hardware
| Size: 2.25 MB
Table of Contents
6
Table of Contents
11
1 Overview of the Multiflex Cub-II and Cub-Td
11
The Multiflex CUB-II
11
The Multiflex CUB-TD
12
2 Mounting and Powering
12
Snap-Track Installation
13
The Plug-In Output Board
13
Powering the Multiflex CUB Board
14
Choosing Transformer Sizes
14
Multiflex CUB Power Wiring
15
New-Style Multiflex CUB Boards (With Isolated Power Supply)
15
Old-Style Multiflex CUB Boards (No Isolated Power Supply)
16
Wire Types and Maximum Distances
17
3 The I/O Network
17
Wiring Types
17
Daisy Chains
17
Network ID Numbers
18
Numbering the Multiflex CUB
18
Setting the Baud Rate
18
Setting the Terminating Resistance Jumpers
19
4 Cub Input and Output Setup
19
The Inputs
19
Connecting Sensors to the Multiflex CUB
19
Wiring
19
Sensor Wiring Types
19
Input Type Dip Switches
20
Power Connection
20
Current Ratings for On-Board Power Sources
20
Powering Sensors Requiring 24VAC Off the Power Transformer
20
Multiflex CUB Fixed Input Locations
21
The Outputs
22
Relay Output Ratings and Fuse Protection
22
Wiring Outputs to Points
22
Multiflex CUB Fixed Outputs
23
5 Board Status Leds
23
Status Led
23
Tx and Rx Leds
23
Code Aand Codeb Led S
24
Relay Output Leds
25
6 Multiflex Cub-II and Cub-Td Software Overview
25
Compressor Control
25
Suction Pressure Compressor Control
25
Case Temperature Compressor Control
25
Pump Down
25
Fallback Pressure Setpoints
26
Condenser Fan Control
26
Temperature Differential (TD) Strategy
26
TD Control Fail-Safes
26
Pressure Control Strategy
27
Case Temperature Control
27
Defrost Control
27
Defrost Termination
27
Sensor Control
27
How Cut In/Cut Out Control Works
28
Motor Room Temperature Control
28
Exhaust Fan Control
28
Example of a Motor Room Zone Temperature Configuration
29
Alarm Conditions (Safety Modes)
29
High Discharge Trip Safety Mode
29
Compressor Proof Fail Safety Mode
30
Compressor Oil Failure Safety Mode
30
Phase Fail Mode
30
Door Switches and Clean (Wash) Switches
30
Door Switches
31
Clean (Wash) Switches
32
7 The Multiflex Cub E2/ Einstein Interface
32
Adding /Deleting Acub
32
Adding a CUB
33
Deleting a CUB
33
Viewing the Cub Status Screen
34
Inputs and Setpoints
35
Sensor Control
35
Outputs and Operational States
36
Defrost
36
KW Usage
36
Programming the Cub Using the E2 or Einstein Front Panel
37
Screen 1: General
38
Screen 2: Setpoints
40
Temperature Differential (TD)
40
Traditional Strategy
41
Screen 3: Inputs
42
Screen 4: Aux Inputs
42
Screen 5: CUB Inputs
44
Screen 6: Defrost
45
Screen 7: Outputs
47
Screen 8: CUB Outputs
48
Screen 9: Sensor Control
49
Screen 10: Alarms
49
Oil Failure Alarm Setpoints
50
Discharge Pressure Alarm
51
High/Low Suction Pressure Alarms
51
Compressor Proof Alarms
52
Phase Fail Shutdown
52
Door Switch Alarms
52
Wash Active Alarms
52
Case Temperature Alarms
53
Suction Temperature Alarms
53
TD Condenser Control Alarms
54
8 The Multiflex Cub Hand-Held Interface
54
CUB Hand-Held Terminal Status Screens
54
Pressure Status
54
Case Temp Status
54
Other Temperatures
55
Input Summary Screen
55
Outputs Summary Screen #1
55
Outputs Summary Screen #2
55
System Status
55
Refrigeration Control Status
55
Altering Cub Configuration Using the Hand -Held Terminal
56
Navigation
56
General Hand-Held Terminal Screens
56
Circuit Name
57
Refrigerant Select
57
Phase
57
Temp EU
58
Time and Date
58
Daylight Savings Time
58
Setpoints Screens
59
Condenser Setpoints
59
TD Strat Info
59
TD Max
59
Comb Method
60
Min OFF/ON Times
61
Condenser Sps
61
Condenser Fan 1 Setpoints
61
Condenser Fan 2 Setpoints
62
Alarm Setpoints Screens
62
Case Hi and Lo Temp
62
Phase Fail
62
Shut Down On Proof
63
Proof Failure
63
Oil Restart Delay
63
Digital Oil Failure
64
High Discharge Alarm
64
High Discharge Auto Resets
64
Door Switch
64
Wash Switch
65
Defrost Setup Screens
65
Defrost Type
65
Fan Control
66
Defrost Times
66
Defrost Schedule Screens 1 and 2
66
Input Setup Screens
66
Input Setup
68
Outputs Screens
68
Auxiliary Inputs Screens
68
Pulse KW Setup
68
Analog KW Setup
68
Linear 1 and 2 Setup
69
Sensor Control Screens
69
Sensor Screen 1 (Name, Type)
69
Sensor Screen 2 (Cut In/Out, Min ON/OFF)
70
Sensor Screen 3 (Hi/Lo Alarm)
72
Appendix A: Td Quick Start
78
Appendix B: Case Type Defaults
Advertisement
Share and save
Advertisement
Related Products
Emerson MultiFlex CUB-TD
Emerson MultiFlex ESR
Emerson MultiFlex Series
Emerson MultiFlex 16
Emerson MultiFlex 88
Emerson MultiFlex 168
Emerson MultiFlex RTU
Emerson AVENTICS MU1
Emerson MW8985W
Emerson mobrey squing 2
Emerson Categories
Controller
Control Unit
Transmitter
Measuring Instruments
Fan
More Emerson Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL