Table of Contents
Table of Contents
3
Introduction
8
Audience SCU Manual
8
Required Knowledge
8
Commissioning and Maintenance Personnel
8
System Engineer
8
How to Use the Clink II Manuals
8
Using the SCU Manual
8
Using the System Overview
8
Using the LCU-5 Manual
9
Referenced Documents
9
Holec Holland Documents
9
Documents from Other Sources
9
Description of the Starter Control Unit
10
Location
10
Function
10
History
10
Design and Layout
10
Safety Instructions
11
Safety Aspects Capitole 40
11
Safety Instructions Clink II
11
Commissioning
12
Placing an SCU
12
Checking the Jumper Setting
12
Setting the Power Supply Configuration
12
Putting the SCU into Operation
13
Functional Description Scu
15
Introduction
15
Measurement
15
Mains Voltage
15
Motor Current
16
Earth Leakage Current
17
Motor Temperature Rise
18
Active Power
23
Power Factor
24
Energy
24
Inputs
25
Digital Inputs
25
Outputs
26
Digital Outputs
26
Analog Output
29
Motor Control
29
Control Levels
30
Switching Conditions
31
Interlockings
32
Starter Logic
32
Tray in Test State
32
Drive Type
32
Starting
33
Starter Logic Direct on Line
35
Starter Logic Star-Delta
35
Starter Logic Forward-Reverse
36
Starter Logic Dual-Speed
37
Stop/Start Commands
39
Command after Communication Failure
40
Automatic Restart
40
Mains Failure Detection
40
Contactor Failure Detection
41
Restart Time out
41
Immediate Restart
42
Delayed Restart
43
No Restart
44
Cancel Automatic Restart
44
Automatic Restart During Starting
44
Automatic Restart During Powerdown
44
Protection
44
Characteristics of Protection Functions
45
Read-Out of Trip and Warning Signals
45
Acknowledge Command
47
Motor Stall
48
Motor Overload
49
Phase Unbalance
50
Earth Leakage
51
Process Underload
51
Process Overload
52
External Protection
53
Over Voltage Protection
53
Under Voltage Protection
53
Under Current Protection
54
Monitoring of Diagnostic and Maintenance Data
54
Number of Operating Hours
54
Number of Contactor Operations
55
Number of Contactor Operations During Last Hour
55
Starting Current
55
Starting Time
56
Trip Current L1, L2, L3
56
Time to Trip
57
Time to Reset
57
Reset Maintenance Command
57
Troubleshooting Guide
58
How to Use the Trouble Shooting Guide
58
States of the SCU
58
Status Module LED
60
Clink II Scu Manager
61
Status Network LED
61
Fault Messages
61
Corrective Actions
63
Maintenance Scu
66
Replacement of the Interface Board
66
Replacement of the Main Board
66
Use of Hyper Terminal
67
Connections
68
Connectors on the Front of the SCU
68
Motor Starter Tray Connections of the Interface Board
69
SCU Print
68
Technical Specifications Main Board and Interface Board
68
Technical Specifications Scu
68
Inputs and Outputs
72
Digital Inputs
72
Analog Inputs
72
Digital Outputs
73
Analog Output
74
Electric Circuit Diagrams Scu
75
Single Line and Auxiliary Circuit Diagrams
75
Direct on Line Starter
75
Star-Delta Starter
77
Forward Reverse Starter
79
Dual Speed Starter
81
Mains Configurations SCU
83
Single Phase Supply (L-N) I < 64A
83
Three Phase Supply Without Neutral. I < 64 a
84
Three Phase Supply Without Neutral. I > 64 a
85
Three Phase Supply with Neutral. I < 64 a
86
Three Phase Supply with Neutral. I > 64 a
87
Glossary
88
Index