EASTMAN Kodak X-Omat 3000 RA PROCESSOR Manuals
Manuals and User Guides for EASTMAN Kodak X-Omat 3000 RA PROCESSOR. We have
3
EASTMAN Kodak X-Omat 3000 RA PROCESSOR manuals available for free PDF download: Adjustments, Diagnostics, Preventive Maintenance
EASTMAN Kodak X-Omat 3000 RA PROCESSOR Adjustments (88 pages)
Brand:
EASTMAN
| Category:
Medical Equipment
| Size: 2 MB
Table of Contents
Table of Contents
2
Service Overview
5
Special Tools
5
Electrostatic Discharge
6
Overview
6
Preventive Measures
6
Service Preparation
6
Preparing the PROCESSOR for Service
7
De-Energizing and Energizing the PROCESSOR
7
Draining the TANKS
8
Filling the TANKS
9
Identifying the RACKS and CROSSOVERS
10
Removing and Installing the RACKS with Solutions in the TANKS
11
Identifying and Removing the COVERS and PANELS
13
Removing the DRYER END PANEL
14
Removing the Remaining PANELS
16
RACKS and CROSSOVERS
17
Adjusting the FEED TRAY
17
Adjusting the Squareness of the CROSSOVERS
18
Adjusting the Squareness of the RACKS
18
Adjusting the GUIDE SHOES on the DEVELOPER RACK
20
Adjusting the GUIDE SHOE on the DRYER RACK
23
Adjusting the DRIVE CHAIN
23
Main Drive
25
Removing the DRIVE SHAFT and the WORM GEARS
25
Removing and Adjusting the Tension of the DRIVE CHAIN
28
Removing the DRIVE MOTOR B6 and the GEAR BOX
29
Removing the BEARING from the DRIVE SHAFT on the Feed End
31
Removing the BEARING from the DRIVE SHAFT on the DRYER
32
Dryer
34
Removing the BLOWER B1
34
Removing the DRYER OVER-TEMPERATURE THERMOSTAT
35
Removing the DRYER THERMISTOR RT3
36
Removing the DRYER HEATER HR3 or THERMAL CUTOFF
37
Plumbing
39
Developer Recirculation System
39
Removing the RECIRCULATION PUMP B5
39
Removing the IMPELLER HOUSING or the IMPELLER
40
Removing the DEVELOPER HEATER HR1
41
Removing the DEVELOPER FILTER
43
Removing the DEVELOPER THERMISTOR RT1
44
Removing the DEVELOPER COOLING SOLENOID L2
45
Removing the HEAT EXCHANGER
46
Fixer Recirculation System
48
Removing the FIXER HEATER HR2
48
Removing the FIXER THERMISTOR RT2
50
Wash System
51
Removing the WASH WATER SOLENOID L1
51
Replenishment System
52
Removing the REPLENISHMENT STRAINERS and SCREENS
52
Removing the DEVELOPER or FIXER REPLENISHMENT PUMP, B3 or B4
53
Removing the POPPET VALVES for the REPLENISHMENT PUMPS
54
Electrical
55
Removing the AUTOTRANSFORMER T1
55
Removing the EMI LINE FILTER FL1 or FL2
56
Removing the SAFELIGHT RECEPTACLE J35
57
Removing the AC CIRCUIT BREAKER CB1
58
Removing the QUAD POWER SUPPLY A1
60
Removing the 5 V DC POWER SUPPLY - for Serial No. 100500 and above
61
Removing the 5 V DC POWER SUPPLY - for Serial Nos. below 100500
62
Adjusting the 5 V DC POWER SUPPLY Voltage - Serial No. below 100500
63
Removing a SOLID STATE RELAY
64
Removing the LEVEL SENSOR HOUSING and LEVEL SENSOR PROBES
65
Removing the 600 BOARD
66
Adjusting the LAMP Intensity on the 2000 BOARD
67
Removing the 2000 BOARD
67
Removing the 3000 BOARD, LCD DISPLAY, and DISPLAY PANEL
69
Display Panel
69
Adjusting the Sensitivity of the DISPLAY PANEL LIGHT SENSOR
71
Removing the 5000 BOARD-Microprocessor
72
Bypassing or Resetting the Access Code
74
Access Code
74
Service Bypass
74
User Reset
74
Downloading the Operating Software
75
Removing the 6000 BOARD
77
Maximizing the Accuracy of the Film Logging Feature
79
Removing the 7000 BOARD and MOTOR CONTROLLER BOARD
80
Removing the 8000 BOARD
82
Adjusting the ACTUATORS and FILM DETECTOR SWITCHES
82
Adjusting the ACTUATORS
82
Adjusting the DETECTOR SWITCHES from Side to Side
84
Adjusting the DETECTOR SWITCH up and down
85
Checking the DETECTOR SWITCHES
86
Advertisement
EASTMAN Kodak X-Omat 3000 RA PROCESSOR Diagnostics (32 pages)
Brand:
EASTMAN
| Category:
Medical Equipment
| Size: 0 MB
Table of Contents
Table of Contents
2
Error Codes
3
Introduction
3
All Errors
3
Fatal Errors
3
Non-Fatal Errors
7
Warnings
12
Mechanical Diagnostics
14
Transport Malfunction
14
Artifacts and Wrong Film Densities
15
Wet Films
18
Solution Levels
20
Internal Diagnostics
21
Accessing the Internal Diagnostics
21
Procedure
21
D1 Menu
22
D2 Menu
22
D3 Menu
22
Diagnostic Menus
23
Overview
23
Details
23
Menus
23
D1 Menu
23
D2 Menu
24
D3 Menu
24
Flowcharts for the Internal Diagnostics
25
Reports
28
Overview
28
Options
28
Requirements
28
Printing Reports
29
Procedure
29
EASTMAN Kodak X-Omat 3000 RA PROCESSOR Preventive Maintenance (14 pages)
Brand:
EASTMAN
| Category:
Medical Equipment
| Size: 0 MB
Table of Contents
Table of Contents
2
Weekly Preventive Maintenance
3
Monthly Preventive Maintenance
5
Month Preventive Maintenance
7
Preventive Maintenance Schedule
11
Publication History
13
Advertisement
Advertisement
Related Products
EASTMAN 3434
EASTMAN Kodak RP X-Omat Processor M6B
EASTMAN 3227
EASTMAN 3059
EASTMAN 4366
EASTMAN Kodak DirectView CR 500 SYSTEM
EASTMAN Kodak X-Omat 1000
EASTMAN Kodak X-Omat 1000A
EASTMAN Kodak X-Omat 1000J
EASTMAN Categories
Industrial Equipment
Cutter
Medical Equipment
Power Tool
Computer Hardware
More EASTMAN Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL