User Manuals: Droplet SP2 Particle Measurement
Manuals and User Guides for Droplet SP2 Particle Measurement. We have
4
Droplet SP2 Particle Measurement manuals available for free PDF download: Manual, Setup And Operation Manual, Setup Manual
Droplet SP2 Setup And Operation Manual (37 pages)
With Auto Sampler
Brand:
Droplet
| Category:
Measuring Instruments
| Size: 2 MB
Table of Contents
Table of Contents
3
1 Unpacking
6
1.1 Preparing the Nebulizer
6
Figure 1: Removing Nebulizer Cover
6
Part I: Setting up the System
6
Figure 2: Removing the Nebulizer's Cardboard Insert
7
Figure 3: Connecting SP2 and SP2 Pump Exhaust Valves
7
2 SP2 Set-Up
7
Figure 4: the "Tee" Connector on the SP2 Purge Port
8
Figure 5: Connecting SP2 Purge Valve and Drying Cartridge
8
Figure 6: Connecting SP2 Pump Purge and Drying Cartridge
8
3 Nebulizer Set-Up
9
1.2 In-Flow Connections
9
Figure 7: Inserting "Tee" Connector into SP2 Inlet
9
Figure 8: Nebulizer In-Flow
9
Figure 9: Alicat Connections
10
Figure 10: Connecting the Inline Filter to the Nebulizer
11
1.3 Out-Flow Connections
12
Figure 11: Waste Tubes Exiting Nebulizer
12
Figure 12: Waste Container
12
Figure 13: Removing Clamp from Nebulizer Aperture
13
Figure 14: Attaching Conductive Tubing to the Nebulizer's Glass Aperture
13
4 Auto Sampler Set-Up
14
1.4 Power Supply and Serial Communications
14
Figure 15: Reattaching the Glass Aperture with the Clamp
14
Figure 16: Connecting the Conductive Tubing from the Nebulizer to the Tee Connector
14
1.5 Sample Flow Components
15
Figure 17: Setting up the Auto Sampler
15
Figure 18: Auto Sampler Tube Connections
16
Figure 19: Tygon Tubing
16
Figure 20: Sample Transfer Tubing
17
1.6 In-Flow Connections
18
Figure 21: Removing Outer Cassette from Peristaltic Pump
18
Figure 22: Threading Tygon Tubing through the Peristaltic Pump's Cassette
18
Figure 23: Reinserting the Cassette in the Peristaltic Pump
19
Figure 24: Attaching the Sample Transfer Tubing to Peristaltic Pump
19
1.7 Out-Flow Connections
20
Figure 25: Connecting the Peristaltic Pump to the Nebulizer
20
5 Peristaltic Pump Set-Up
17
Figure 26: Plugging in Power to Alicat Flow Controller
21
Figure 27: Disconnecting the Nebulizer from the SP2
21
Part II: Turning the System on and off
21
6 Turning on the System
21
Figure 28: SP2 Software Icon
22
Figure 29: Verifying the Config File on the Config Tab
22
Figure 30: Loading a New Configuration File
23
Figure 31: Selecting the Desired Config File
23
Figure 32: Sample Flow Stabilizing
24
Figure 33: Closing the Nebulizer Latch
24
Figure 34: Nebulizer with Latch Closed
25
Figure 35: Turning on the Nebulizer
25
Figure 36: Pressing the Nebulizer "Operate" Button
26
Figure 37: Waste Container
26
Figure 38: Latching the Peristaltic Clamp on the Auto Sampler
27
Figure 39: Turning on the Auto Sampler
27
Figure 40: Inserting Cassette in Peristaltic Pump
28
Figure 41: Turning on the Peristaltic Pump
28
Figure 42: Starting Auto Sampler Rinse Sequence
29
Figure 43: Turning on the Laser from the Control Tab
30
Figure 44: Verifying Particle Response
31
Figure 45: Reconnecting the Nebulizer to the SP2
31
Figure 46: Loading the Auto Sampler Rack
32
Figure 47: Configuring "Start Sample #" and "End Sample
33
Figure 48: Running the Auto Sampler
33
Figure 49: Running the "A-S Home" Sequence
34
7 Turning off the System
34
Figure 50: Turning the Laser off
35
Figure 51: Releasing the Cassette from the Peristaltic Pump
35
Figure 52: Unlatching the Peristaltic Clamp on the Auto Sampler
36
Figure 53: Turning off the Nebulizer
36
Figure 54: Opening the Nebulizer Latch
37
Figure 55: Unplugging the Alicat Flow Controller
37
Advertisement
Droplet SP2 Manual (39 pages)
Single Particle Soot Photometer
Brand:
Droplet
| Category:
Measuring Instruments
| Size: 2 MB
Table of Contents
Table of Contents
3
1 Introduction: Laser Cavity Performance
5
Figure 1: Nd: YAG Laser Resonator Cavity
5
2 Sequence of Laser Cavity Troubleshooting
6
Figure 2: Troubleshooting Sequence
7
3 Minor Alignment Process (First Option)
8
Figure 3: SP2 Spectrometer Head
8
Equipment
9
Required Tools
9
Recommended Tool
9
Step-By-Step Instructions for a Minor Alignment
9
Figure 4: Mode Aperture Removal
10
Figure 5: Installing Mode Aperture in Upside-Down Position
11
Figure 6: Satisfactory Beam Profile
12
Figure 7: Undesired Higher Mode
12
Figure 8: Coupler Chamber Sealing Screws
13
Figure 9: Tip/Tilt Adjustment of Output Coupler Mount
13
Figure 10: Angled Entry of Drivers in Older Systems
13
Figure 11: Attachment of Mode Aperture Alignment Tool
15
Figure 12: Manual Mode Aperture Alignment
15
Figure 13: Application of Extra Force to Assist Stage Springs
16
Figure 14: Histogram Response as Chamber Plate Is Translated
17
4 Major Alignment Process (Second Option)
18
Time Requirements
18
Dangers of ESD Shock
19
Tools
19
Required Tools
19
Additional Recommended Tool
19
Step-By-Step Instructions for a Major Alignment
20
Figure 15: Ultra-Torr Fiber Passthrough Fitting
20
Figure 16: Unscrewing SMA Connector
21
Figure 17: Components of Fiber Passthrough
21
Figure 18: Assembled SP2 Alignment Fixture
22
Figure 19: Frame-To-Fixture Fasteners
22
Figure 20: Removing Output Coupler Mounting Screws
23
Figure 21: Wiping the Output Coupler
24
Figure 22: YAG Crystal and Optical Pump Assembly
25
Figure 23: Fasteners Securing YAG Crystal Holder to Pump Base
26
Figure 24: Three Fasteners Secure TMA to YAG Crystal Holder
27
Figure 25: Screws Securing Halves of YAG Crystal Holder Together
27
Figure 26: YAG Crystal Cushioned in Holder
28
Figure 27: Alignment Beam Centered on Pinholes
30
Figure 28: Paper between Crystal and Mode Match Optics
31
Figure 29: Adjusters that Aim the YAG Crystal Assembly
31
Figure 30: Beam and Reflection Coincidence
32
Figure 31: Paper Placed to Block Reflection from Crystal Face
33
Figure 32: Light Concentric Around Entrance to Coupler Chamber
34
Figure 33: Locking and Adjustment Screws
35
Figure 34: Centered Chamber (Coplanar Slide Plate and Slide Rail End Faces)
36
Appendix A: Tools and Replacement Items from DMT
37
Appendix B: SP2 YAG Pump Laser Storage & Handling Instructions
37
Storing the SP2 YAG Pump Laser
37
Handling the SP2 YAG Laser
37
Figure 35: SP2 Pump Laser in Protective Box
37
Figure 36: Shorting Plug Detached (Left) and Attached (Right) to Power Connector
38
Figure 37: Protective Cap SMA Fiber Connector; Cap Attached to Connector
38
Appendix C: Revisions to Manual
39
Droplet SP2 Setup Manual (24 pages)
Brand:
Droplet
| Category:
Measuring Instruments
| Size: 1 MB
Table of Contents
Table of Contents
2
Specifications
4
General Specifications for the APEX 2Q Nebulizer
4
Electrical Specifications for the APEX 2Q Nebulizer
4
Physical Specifications of the APEX 2Q Nebulizer
4
General Information
5
Safety Information
5
Brief Theory of Operation
5
Figure 1: Diagram of Flow and Gas Connections for Operation of APEX 2Q with SP2
5
Figure 2: Plumbing Tee Connection from Nebulizer to SP2
6
Introduction
7
Part 1: Unpacking, Setup, Installation, and Power up
8
Contents
8
Figure 3: Check Critical Components
8
Figure 4: Unpacking the Nebulizer, Documentation, Power Cords, and Alicat
9
Figure 5: Using the Zero Filter
10
SP2 Set-Up
10
Nebulizer Set-Up
11
APEX 2Q Nebulizer Used with the SP2 (Refer to APEX 2Q Manual)
11
Mass Flow Controller Set-Up
11
Connecting the Mass Flow Controller
11
Figure 6: Connecting the Mass Flow Controller
11
Set Communication between SP2 and Flow Controller
12
Figure 7: SP2 Software Icon and Device Manager Tab
12
Figure 8: Finding COM Port with Device Manager
12
Figure 9: Unplugging Power to Alicat Flow Control
13
Part II: Turning the System on and off
14
SP2, and Nebulizer System
14
SP2 Pre-Sampling Warm-Up
14
Figure 10: ZERO Filter Attached
14
Figure 11: SP2 Program Launch Icon
14
Figure 12: Config Tab, and Program Subtab
15
Figure 13: Plug in the Alicat Controller and Verify Flow
15
Figure 14: Enabling the Alicat, Save and Restart the Program
16
Figure 15: Turn on the SP2 Pump
16
Figure 16: Turning the Laser on
16
Figure 17: Sample Flow Stabilizing
17
Powering up the Nebulizer System
18
Figure 18: Waste Container, and Turning on the Nebulizer
18
Figure 19: Working Nebulizer and Temperature Indicators
18
Figure 20: Turning on the Laser from the Control Tab
19
Figure 21: Verifying Particle Response
20
Turning off the System
21
Figure 22: Reconnecting the Nebulizer to the SP2
21
Figure 23: Turning the Laser off
21
Figure 24: Turning off the Nebulizer
22
Figure 25: Remove Sample Tube from Sample Container
22
Additional Questions
23
Appendix A: Warranty and Contact Information
24
Advertisement
Droplet SP2 Manual (13 pages)
Beam-Scan Camera and Software
Brand:
Droplet
| Category:
Measuring Instruments
| Size: 0 MB
Table of Contents
Table of Contents
3
Figure 1: SP2 Laser Mode in the TEM Oo Mode, as Viewed in the Vbeam Control Panel
7
Figure 2: the SP2 Laser Beam in the TEM Oo Mode, as Viewed in the Surface Plot
8
Figure 3: SP2 Laser Beam in the TEM Oo Mode, as Viewed in the Graphical Plot
8
Figure 4: the SP2 Laser Beam in a Higher-Order Mode, as Viewed in the Vbeam
9
Figure 5: the SP2 Laser Beam Plot in a Higher-Order Mode
10
Figure 6: the SP2 Laser Beam Viewed Graphically in a Higher-Order Mode
10
Troubleshooting
12
Appendix A: Changes to Manual
12
Appendix B: Assembly Drawing
13
Advertisement
Related Products
Droplet SP2-XR
Droplet SP2-D
Droplet APEX 2Q
Droplet CAS-DPOL
Droplet CCN-200
Droplet CDP-2
Droplet Dual-Column CCN
Droplet Categories
Measuring Instruments
Laboratory Equipment
Indoor Fireplace
Water System
More Droplet Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL