Manuals and User Guides for Droplet SP2-D. We have
2
Droplet SP2-D manuals available for free PDF download: Operator's Manual, Setup Manual
Droplet SP2-D Operator's Manual (35 pages)
Single Particle Soot Photometer
Brand:
Droplet
| Category:
Measuring Instruments
| Size: 1 MB
Table of Contents
Table of Contents
5
1 Introduction
7
Specifications
7
Electrical Specifications
9
Physical Specifications
9
Operating Limits
9
Figure 1: Front View of the SP2 Analyzer
10
2 Theory of Operation
10
Figure 2: Rear View of the SP2 Analyzer Chassis
11
Figure 3: Schematic Diagram of the YAG Laser in the SP2
12
Figure 4: SP2 Optical Diagram
13
Control Board Inputs
14
Optical Detectors
13
Laser Characteristics
12
Figure 5: Connecting SP2 and SP2 Pump Exhaust Valves
14
3 Unpacking and Setup
14
Set up
14
Unpacking
14
Figure 7: Connecting SP2 Pump Purge Port to Drierite Cartridge
15
Figure 6: Connecting SP2 Purge Valve to Drierite Cartridge
15
Figure 8: Connecting the SP2 Purge Valve to the SP2 Pump Purge Port
16
Turning on the System
16
Figure 9: Verifying the Config File on the Config Tab
17
Figure 10: Loading a New Configuration File
18
Figure 11: Sample Pump Power Switch
19
Figure 12: Sample Flow Stabilizing
19
Figure 13: Turning on the Laser from the Control Tab
20
Figure 14: Verifying Particle Response
21
Turning off the System
22
4 Flow System
22
Figure 15: Turning the Laser off
22
5 Typical Operating Parameters
23
6 Laser Safety Interlocks
23
Figure 17: Laser Interlocks (Circled in Lower Left and Upper Right of SP2)
24
Figure 16: SP2 Key in the Locked (Left) and Unlocked (Right) Positions
24
Figure 18: Interlock Jumper
25
Cleaning the Laser Optics
26
Procedure for Alignment of the YAG Laser
26
SP2-D: Procedure to Calibrate the Laminar Flow Element
26
7 Routine Maintenance
25
Figure 19: Schematic Diagram for SP2 Calibration with DMA
27
8 Calibrating the Instrument with Aerosol Black Carbon
27
Required Equipment
27
Calibration Procedure
27
9 Troubleshooting
28
Appendix A: Revisions to Manual
29
Figure 20: SP2 Pump Laser in Protective Box
30
Handling the SP2 YAG Laser
31
Appendix B: SP2 YAG Pump Laser Storage and Handling Instructions
30
Storing the SP2 YAG Pump Laser
30
Figure 21: Shorting Plug Detached (Left) and Attached (Right) to Power Connector
31
Figure 22: Protective Cap and SMA Fiber Connector (Above); Cap Attached to Connector
31
Appendix C: Configuring and Testing the Sp2'S Four Analog Input Channels
32
Configuration
32
Figure 23: Configuring Analog Input (AI) Channels in the SP2-D
33
Testing the Input Voltages
34
Figure 24: Control Tab Display of Newly Added AI Channels
34
Appendix D: Plumbing Diagram
35
Appendix E: SP2-D System Schematic
35
Advertisement
Droplet SP2-D Setup Manual (24 pages)
Brand:
Droplet
| Category:
Measuring Instruments
| Size: 1 MB
Table of Contents
Table of Contents
2
Specifications
4
General Specifications for the APEX 2Q Nebulizer
4
Electrical Specifications for the APEX 2Q Nebulizer
4
Physical Specifications of the APEX 2Q Nebulizer
4
General Information
5
Safety Information
5
Brief Theory of Operation
5
Figure 1: Diagram of Flow and Gas Connections for Operation of APEX 2Q with SP2
5
Figure 2: Plumbing Tee Connection from Nebulizer to SP2
6
Introduction
7
Part 1: Unpacking, Setup, Installation, and Power up
8
Contents
8
Figure 3: Check Critical Components
8
Figure 4: Unpacking the Nebulizer, Documentation, Power Cords, and Alicat
9
Figure 5: Using the Zero Filter
10
SP2 Set-Up
10
Nebulizer Set-Up
11
APEX 2Q Nebulizer Used with the SP2 (Refer to APEX 2Q Manual)
11
Mass Flow Controller Set-Up
11
Connecting the Mass Flow Controller
11
Figure 6: Connecting the Mass Flow Controller
11
Set Communication between SP2 and Flow Controller
12
Figure 7: SP2 Software Icon and Device Manager Tab
12
Figure 8: Finding COM Port with Device Manager
12
Figure 9: Unplugging Power to Alicat Flow Control
13
Part II: Turning the System on and off
14
SP2, and Nebulizer System
14
SP2 Pre-Sampling Warm-Up
14
Figure 10: ZERO Filter Attached
14
Figure 11: SP2 Program Launch Icon
14
Figure 12: Config Tab, and Program Subtab
15
Figure 13: Plug in the Alicat Controller and Verify Flow
15
Figure 14: Enabling the Alicat, Save and Restart the Program
16
Figure 15: Turn on the SP2 Pump
16
Figure 16: Turning the Laser on
16
Figure 17: Sample Flow Stabilizing
17
Powering up the Nebulizer System
18
Figure 18: Waste Container, and Turning on the Nebulizer
18
Figure 19: Working Nebulizer and Temperature Indicators
18
Figure 20: Turning on the Laser from the Control Tab
19
Figure 21: Verifying Particle Response
20
Turning off the System
21
Figure 22: Reconnecting the Nebulizer to the SP2
21
Figure 23: Turning the Laser off
21
Figure 24: Turning off the Nebulizer
22
Figure 25: Remove Sample Tube from Sample Container
22
Additional Questions
23
Appendix A: Warranty and Contact Information
24
Advertisement
Related Products
Droplet SP2-XR
Droplet SP2
Droplet APEX 2Q
Droplet CAS-DPOL
Droplet CCN-200
Droplet CDP-2
Droplet Dual-Column CCN
Droplet Categories
Measuring Instruments
Laboratory Equipment
Indoor Fireplace
Water System
More Droplet Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL