Sign In
Upload
Manuals
Brands
Cygnus Manuals
Measuring Instruments
M5-C4P
Cygnus M5-C4P Ultrasonic Thickness Gauge Manuals
Manuals and User Guides for Cygnus M5-C4P Ultrasonic Thickness Gauge. We have
1
Cygnus M5-C4P Ultrasonic Thickness Gauge manual available for free PDF download: Operating Manual
Cygnus M5-C4P Operating Manual (140 pages)
Cygnus 4+ Multi-Mode Ultrasonic Thickness Gauge
Brand:
Cygnus
| Category:
Measuring Instruments
| Size: 3.18 MB
Table of Contents
Operating Manual
1
Table of Contents
3
1 Important Notice
8
2 Introduction
9
Cygnus 4 + Thickness Gauge
9
Cygnus Instruments
10
Gauge Kit Contents
11
Basic Gauge Kit
11
Kit Supplied with Single Element Probe
11
Kit Supplied with Twin Element Probe
11
3 Gauge Preparation
12
Fitting the Batteries
12
Connecting the Probe
13
Fitting the Neck Strap
14
4 Selecting the Right Probe
15
Measuring Metals
15
Measurement Modes Explained and Compared
16
Multiple Echo Mode (ME) (Mode 3)
16
Single Echo Mode (SE) (Mode 2)
16
Echo-Echo Mode (EE) (Mode 3)
17
Measuring Non-Steels
17
Measuring Non-Metals
18
Single Element Probes and Protective Membranes
18
Measuring Higher Temperatures
19
Summary of Cygnus Probes
21
Twin Element Probes
21
Single Element Probes
21
The 'Probe Type' Code
22
5 Gauge Operation
23
Gauge Controls
23
Turning the Gauge on
24
Turning the Gauge off
24
Automatic Power off
24
Measurement Screen Views
25
Status Information
26
Taking Thickness Measurements
27
Zeroing the Probe (Twin Element Probes)
27
Taking the Thickness Measurement
27
Echo Indicators in Multiple Echo Mode
28
Measurement Stability Indication in SE & EE Modes
29
Measuring Small Diameter Pipe & Tubes
30
Display Hold Function
30
Battery Life
31
Battery Level
31
Low Battery Indication
32
6 Using the A-Scan Display
33
Single Echo Mode
33
Measuring over Corrosion Pits
34
Echo-Echo Mode
35
Multiple Echo Mode
36
7 Calibration
38
Why Should I Calibrate My Thickness Gauge
38
Calibration Options
39
Calibrating to a Known Thickness (Single or 1 Point)
39
Two Point Calibration
41
Ladder Step Wedge
41
Two Point Calibration Procedure
42
Probe Zero (Twin Element Probes)
44
Starting a Probe Zero from the Main Menu
45
Probe Zero Function
45
Setting the Velocity of Sound
46
8 Gauge Setup
48
Menu Operation
48
Settings Are Saved with the Probe Type
49
Inputting Numeric Values Using the Navigation Keys
50
Inputting Text Using the Navigation Keys
50
Selecting the Probe Type
52
Automatic Probe Detection
53
Measurement Units
54
Resolution Setting
54
Limit Functions
55
Deep Coat Function (Multiple Echo Mode)
58
9 Data Logging
61
Data Logging Features
61
Record Types
62
Reference and Minimum Thicknesses
62
Minimum Thickness Limit Alert
62
Radial Points
62
Measurement Comments
63
Loading Measurement Comments from a File
64
Grid Records
64
Template Records
66
Data Logging Menu
66
Creating a New Record
66
Your Choices will be Saved for Next Time
68
Using a Template to Create a New Record
69
User Field Input
69
Reviewing and Editing User Field Choices
69
Logging Thickness Measurements
70
Auto-Log Feature
71
Logging Obstructions and No-Readings
72
Changing Measurement Units While Data Logging
73
Re-Taking the Last Measurement
73
Stepping Backwards in the Record
74
Adding Radial Points
75
Adding Measurement Comments
77
Closing and Opening a Record
78
Closing the Record
79
Opening a Record
79
Protecting a Record
80
Opening Protected Records
82
Deleting Records
82
Deleting Individual Records
83
Deleting All Records
84
Record Status
84
10 Data Logging Templates
86
Templates
86
Integrating with Microsoft Excel
87
Measurement Points
87
User Fields
88
User Field 'List' Type
88
11 Manual Gain Adjustment
89
Manual Gain Mode
89
Turning on Manual Gain
89
Manual Gain Menu
90
Adjusting the Gain
91
Adjusting the Range
92
Measuring below the Probes Minimum Thickness Specification
93
12 Setup Menu
94
A-Scan Range
94
Automatic
94
Manual
94
Vibrate Feature
94
Brightness Setting
94
Power off Setting
95
Auto-Log
95
Comments
95
Set Time and Set Date
96
13 General Points on Thickness Gauging
97
14 Troubleshooting
98
The Gauge will Not Switch on
98
Difficulty Obtaining a Reading
98
If Readings Are Erratic or Unstable
98
Tips for Optimising Battery Life
98
15 Updating Your Gauge
100
Update Software
100
Gauge Firmware Files
100
16 Care and Servicing
101
Cleaning the Gauge
101
Batteries
101
Environmental
101
Repairs
101
Returning the Gauge for Servicing
102
17 Cyglink Computer Software
103
Installing Cyglink
104
Requirements
104
Upgrading
104
Installing
104
Connecting to the Gauge
105
First Time USB Connection
105
Connecting the Gauge to Cyglink for the First Time
106
Connecting to the Gauge Afterwards
107
Disconnecting from the Gauge
107
Manual Connection Settings
107
Status Bar
107
Surveys
108
Creating a New Survey
108
Opening an Existing Survey
109
Editing the Survey Info
109
Managing the Survey
109
Sorting Survey Records
109
Viewing Record Information
110
Ref and Min Thickness
111
Protection State
112
Measurement Summary Stats
112
Data Logger Records
112
Transferring Records from the Gauge
112
Viewing Thickness Measurements in a Record
114
Managing Measurements
114
Viewing Measurement Information
115
Adding Comments to Measurements
116
Viewing an A-Scan Graph
117
Deleting All Records from the Gauge
118
Measurement Comment List
119
Material Velocity List
120
Creating a PDF Survey Report
121
Exporting a Survey to a CSV File
122
Templates
123
Creating New Templates
123
Editing Templates
124
Sending Templates to the Gauge
127
Deleting Templates from the Gauge
128
Other Features
128
Setting the Time and Date on the Gauge
128
COM Port Numbers
128
Finding Your COM Port Number
128
18 Information
130
Technical Specifications
130
Table of Sound Velocities
134
Reading Conversions
135
19 EU Declaration of Conformity
136
20 Recycling and Disposal (EC Countries)
137
21 Warranty Information
138
22 Index
139
Advertisement
Advertisement
Related Products
Cygnus M5-C2P
Cygnus MR400
Cygnus M5-C2
Cygnus M5-C4
Cygnus M5-ROV-ASCAN
Cygnus MC-100
Cygnus M2-DIVE
Cygnus MR 500
Cygnus MINI ROV
Cygnus M3-DIVE
Cygnus Categories
Measuring Instruments
Diving Instrument
Lighting Equipment
Monitor
Automobile Accessories
More Cygnus Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL