Combustion Area And Vent System - Bryant PLUS 95S 355CAV Owner's Manual

Direct vent 4-way multipoise modulating condensing gas furnace with perfect sense perfect humidity
Hide thumbs Also See for PLUS 95S 355CAV:
Table of Contents

Advertisement

Fig. 30 - - Replace Furnace Door
Fig. 31 - - Replace Side Filter Cabinet Door
5. If washable filter, wash filter (if dirty) in sink, bathtub, or
outside with a garden hose. Always use cold tap water. A
mild liquid detergent may be used if necessary. Spray
water through filter in the opposite direction of airflow.
Allow filter to dry.
6. Reinstall clean air filter.
7. Reinstall filter retainer (for blower compartment locations
only).
8. Replace blower access panel and main furnace door (Fig.
29 and 30.) or filter cabinet door. (Fig. 31 and 32.)
9. Turn on electrical supply to furnace.
If your furnace air filter needs to be replaced, be sure to use a
factory- -authorized filter of the same size that was originally
supplied. Use the filter tables and compare your furnace size with
the proper filter size.
Fig. 32 - - Replace Bottom Filter Cabinet Door
AIR FILTER LOCATED IN BLOWER COMPARTMENT
A05088
FURNACE
CASING
WIDTH
IN (mm)
17–1/2
(445)
21 (533)
24–1/2
(622)
AIR FILTER LOCATED IN FILTER CABINET
FILTER CABINET
HEIGHT --- IN (mm)
16 (406)
20 (508)
24 (610)
A06192
*Factory ---provided with the furnace. Filters may be field modified by
cutting filter material and support rods (3) in filters.
{ Upflow only. Alternate sizes and additional filters may be ordered from
your dealer.
!
PERSONAL INJURY HAZARD
Failure to follow this warning could result in personal
injury.
Use care when cutting support rods in filters to protect
against flying pieces and sharp rod ends. Wear safety
glasses, gloves, and appropriate protective clothing.
COMBUSTION AREA AND VENT
SYSTEM
Visually inspect the combustion area and vent system before each
heating season. Make sure that all PVC pipes leading into the
combustion area and vent are free from any cracks and sags.
10
FURNACE AIR FILTER TABLE
FILTER SIZE --- IN (mm)
Side Return†*
Bottom Return*
(1) 16 X 25 X 3/4
(1) 16 X 25 X 3/4
(406 X 635 X 19)
(406 X 635 X 19)
(1) 16 X 25 X 3/4
1) 20 X 25 X 3/4
(406 X 635 X 19)
(508 X 635 X 19)
(1 or 2) 16 X 25 X
(1) 24 X 25 X 3/4
3/4
(610 X 635 X 19)
(406 X 635 X 19)
FILTER
SIZE --- IN (mm)
(1) 16 x 25 x 3/4*
(406 X 635 X 19)
(1) 20 x 25 x 3/4*
(508 X 635 X 19)
or
(1) 20 x 25 x 4 ---5/16
(508 X 635 X 110)
(1) 24 x 25 x 3/4*
(610 X 635 X 19)
or
(1) 24 x 25 x 4 ---5/16
(610 X 635 X 110)
WARNING
A06193
FILTER
TYPE
Washable
Washable
Washable
FILTER
TYPE
Washable
Washable
Washable

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Plus 95s355cav

Table of Contents