Sign In
Upload
Manuals
Brands
Belden Manuals
Control Unit
Lumberg Automation LioN-P PROFINET IO-Link Master 0980 ESL 199-331
Belden Lumberg Automation LioN-P PROFINET IO-Link Master 0980 ESL 199-331 Manuals
Manuals and User Guides for Belden Lumberg Automation LioN-P PROFINET IO-Link Master 0980 ESL 199-331. We have
4
Belden Lumberg Automation LioN-P PROFINET IO-Link Master 0980 ESL 199-331 manuals available for free PDF download: Manual
Belden Lumberg Automation LioN-P PROFINET IO-Link Master 0980 ESL 199-331 Manual (111 pages)
PROFINET IO-Link Master
Brand:
Belden
| Category:
Control Unit
| Size: 3 MB
Table of Contents
Table of Contents
2
About this Manual
7
General Information
7
Explanation of Symbols
8
Use of Danger Information
8
Use of General Information
8
Version Information
9
Safety Instructions
10
Intended Use
10
Qualified Personnel
11
Designations and Synonyms
12
System Description
13
PROFINET Product Features
13
IO Port Features
16
Integrated Web Server
17
Other Features
19
Product Overview
20
Assembly and Wiring
22
General Information
22
Outer Dimensions
23
Module 0980 ESL 3X8-121 & ESL 3X9-121
23
Module 0980 ESL 1X9-121
24
Module 0980 ESL 1X9-332
25
Module 0980 ESL 1X9-122
26
Module 0980 ESL 1X9-331
27
Port Assignments
28
PROFINET Ports, M12 Socket, 4-Pin, D-Coded
28
Power Supply with M12 Power L-Coded
29
PROFINET and Power Supply with M12 Hybrid
30
IO Ports as M8 or M12 Sockets
31
IO-Link Type a
31
IO-Link Type B
32
Starting Operation
34
GSDML File
34
MAC Addresses
34
State on Delivery
35
Configuration of the Lion-P PROFINET IO Modules in STEP
35
Assigning a Unique Device Name
36
Assigning a Device Name to a Lion-P Module
36
Configuring the IO-Link Channels
37
Deleting the Configuration of an IO-Link Channel
38
Creating an IO-Link Channel Configuration
40
Parameterization of the IO-Link Channels
42
IOL Parameter Storage
42
IOL Device Validation
45
Fail Safe Configuration (for Outputs Only)
46
Parameterization of the Status/Control Module
48
General Device Settings
48
General Diagnosis Settings
49
Fail Safe Value (DO-Mode)
50
Surveillance Timeout Configuration (Lion-P 60 Devices)
51
Digital Input Logic
52
Digital-IO Mode for Ch. B/Pin
53
Digital-IO Mode for Ch. B/Pin 2 (Lion-P 30 Devices)
53
Digital-IO Mode for Ch. B/Pin 2 (Lion-P 60 Devices)
53
IO-Link Device Parameterization
55
SIEMENS IO-Link Library
55
Snmp
57
Media Redundancy Protocol (MRP)
58
Identification & Maintenance Functions (I&M)
61
Supported I&M Features
62
Module-Specific I&M Features
62
IO-Link Master I&M Functions
63
IO-Link Device I&M Functions
65
Reading and Writing I&M Data
65
I&M Read Record
66
I&M Write Record
67
Fast Start-Up (FSU) / Prioritized Start-Up
69
Bit Assignment
70
Process Data Status and Control Module, Slot 1/Sub-Slot
70
Digital IO Mapping Mode 1 (Default Mapping)
70
Input Data of the Status/Control Modules
70
Output Data of the Status/Control Modules (Except 0980 ESL 3X8-121)
72
Output Data of the Status/Control Modules for 0980 ESL 3X8-121
74
Digital IO Mapping Mode 2 (E2C Compatibility)
75
Input Data of the Status/Control Modules
75
Output Data of the Status/Control Modules (Except 0980 ESL 3X8-121)
77
Output Data of the Status/Control Modules for 0980 ESL 3X8-121
79
Process Data IO-Link Ports, Slot 1/Sub-Slot 2 - Sub-Slot
80
Diagnostics Processing
81
Error of the System/Sensor Power Supply
81
Error of the Auxiliary/Actuator Power Supply
81
Overload/Short-Circuit of the IO Port Sensor Supply Outputs
82
Overload/Short Circuit of the Digital 500 Ma Outputs
83
Overload/Short Circuit of the Digital Outputs
83
Overload/Short Circuit of the Type B Port Aux. Power Supply
85
For Lion-P 30 Devices
85
For Lion-P 60 Devices
85
IO-Link C/Q Error
86
IO-Link Device Diagnostics
87
Port Configuration Tool
89
The Integrated Web Server
91
The Status Page
92
The Ports Page
95
The System Page
96
The User Page
98
Technical Data
99
General
99
PROFINET Protocol
100
Power Supply of the Module Electronics/Sensors
101
Power Supply of the Type B Ports (Auxiliary Supply)
102
IO-Link Master Ports (X1 - X8, Ch. a / C/Q / Pin 4)
102
Configured as a Digital Input
103
Configured as a Digital Output (Except 0980 ESL 3X8-121)
103
Configured as an IO-Link Port in COM Mode
104
Digital Inputs (X1 - X4, Type a Ports, Ch. B/Pin 2)
104
Lion-P 60: U aux
106
B/Pin 2)
106
Lion-P 30: U aux (X5 - X8)
107
Manual Lion-P PROFINET IO-Link Master
111
Advertisement
Belden Lumberg Automation LioN-P PROFINET IO-Link Master 0980 ESL 199-331 Manual (108 pages)
Brand:
Belden
| Category:
Control Unit
| Size: 3 MB
Table of Contents
Table of Contents
2
1 About this Manual
6
General Information
6
Explanation of Symbols
7
Use of Danger Information
7
Use of General Information
7
Version Information
7
2 Safety Instructions
8
Intended Use
8
Qualified Personnel
9
3 Designations and Synonyms
10
4 System Description
11
PROFINET Product Features
11
IO Port Features
14
Integrated Web Server
15
Other Features
16
Product Overview
17
5 Assembly and Wiring
19
General Information
19
Outer Dimensions
20
Module 0980 ESL 3X8-121 & ESL 3X9-121
20
Module 0980 ESL 1X9-121
21
Module 0980 ESL 1X9-332
22
Module 0980 ESL 1X9-122
23
Module 0980 ESL 1X9-331
24
Port Assignments
25
PROFINET Ports, M12 Socket, 4-Pin, D-Coded
25
Power Supply with M12 Power L-Coded
26
PROFINET and Power Supply with M12 Hybrid
27
I/O Ports as M8 or M12 Sockets
28
6 Starting Operation
31
GSDML File
31
MAC Addresses
31
State on Delivery
31
Configuration of the Lion-P PROFINET I/O Modules in STEP
32
Assigning a Unique Device Name
32
Assigning a Device Name to a Lion-P Module
33
Configuring the IO Link Channels
34
Parameterization of the IO Link Channels
39
Parameterization of the Status/Control Module
45
Surveillance Timeout Configuration (Lion-P 60 Devices)
48
Digital Input Logic
49
Digital-IO Mode for Ch. B/Pin
50
IO-Link Device Parameterization
52
SIEMENS IO-Link Library
52
Snmp
54
Media Redundancy Protocol (MRP)
55
Identification & Maintenance Functions (I&M)
58
Supported I&M Features
59
Reading and Writing I&M Data
62
Fast Start-Up (FSU) / Prioritized Start-Up
66
7 Bit Assignment
67
Process Data Status and Control Module, Slot 1/Sub-Slot
67
Digital IO Mapping Mode 1 (Default Mapping)
67
Digital IO Mapping Mode 2 (E2C Compatibility)
72
Process Data IO-Link Ports, Slot 1/Sub-Slot 2 - Sub-Slot
77
8 Diagnostics Processing
78
Error in the System/Sensor Power Supply
78
Error in Auxiliary/Actuator Power Supply
78
Overload/Short-Circuit of the IO Port Sensor Supply Outputs
79
Overload/Short Circuit of the Digital 500 Ma Outputs
80
Overload/Short Circuit of the Digital Outputs
80
Overload/Short Circuit of the Type B Port Aux. Power Supply
82
For Lion-P 30 Devices
82
For Lion-P 60 Devices
82
IO-Link C/Q Error
82
IO-Link Device Diagnostics
83
9 Port Configuration Tool
86
10 The Integrated Web Server
88
The Status Page
89
The Ports Page
92
The System Page
93
The User Page
95
11 Technical Data
96
General
96
PROFINET Protocol
97
Power Supply for the Module Electronics/Sensors
98
Power Supply Type B Ports (Auxiliary Supply)
99
IO-Link Master Ports (X1 - X8, Ch. A/C/Q/ Pin 4)
99
Configured as a Digital Input
100
Configured as a Digital Output (Except 0980 ESL 3X8-121)
100
Configured as an IO-Link Port in COM Mode
101
Digital Inputs (X1 - X4, Type a Ports, Ch. B/Pin 2)
101
Lion-P 60: U Aux
103
B/Pin 2)
103
Lion-P 30: U Aux (X5 - X8)
104
Differences between 0980 ESL 3X8-121 and 0980 ESL 3X9-121
105
Leds
106
12 Accessories
108
Belden Lumberg Automation LioN-P PROFINET IO-Link Master 0980 ESL 199-331 Manual (13 pages)
Digital I/O modules and IO-Link Master
Brand:
Belden
| Category:
Control Unit
| Size: 0 MB
Table of Contents
Table of Contents
3
1 About this Manual
5
General Information
5
Version Information
5
2 About the Lion-P Module Series
6
3 Multiprotocol
7
4 Protocol Settings for Digital I/O Modules
8
Ethernet/Ip - PROFINET - Ethercat
8
Ethernet/Ip
9
Profinet
10
Ethercat
10
Factory Reset
10
5 Protocol Settings for IO-Link Master
11
Ethernet/Ip - PROFINET
11
Ethernet/Ip
12
Profinet
12
Factory Reset
13
Advertisement
Belden Lumberg Automation LioN-P PROFINET IO-Link Master 0980 ESL 199-331 Manual (13 pages)
Brand:
Belden
| Category:
Control Unit
| Size: 0 MB
Table of Contents
Table of Contents
2
About this Manual
3
General Information
3
Version Information
4
About the Lion-P Module Series
5
Multiprotocol
6
Protocol Settings for Digital I/O Modules
7
Ethernet/Ip - PROFINET - Ethercat
7
Ethernet/Ip
9
Profinet
9
Ethercat
9
Factory Reset
10
Protocol Settings for IO-Link Master
11
Ethernet/Ip - PROFINET
11
Ethernet/Ip
12
Profinet
13
Factory Reset
13
Advertisement
Related Products
Belden Lumberg Automation LioN-P PROFINET IO-Link Master 0980 ESL 109-121
Belden Lumberg Automation LioN-P PROFINET IO-Link Master 0980 ESL 199-121
Belden Lumberg Automation LioN-P PROFINET IO-Link Master 0980 ESL 109-332
Belden Lumberg Automation LioN-P PROFINET IO-Link Master 0980 ESL 199-332
Belden Lumberg Automation LioN-P PROFINET IO-Link Master 0980 ESL 109-331
Belden Lumberg Automation LioN-P PROFINET IO-Link Master 0980 ESL 109-122
Belden Lumberg Automation LioN-P PROFINET IO-Link Master 0980 ESL 199-122
Belden lumberg automation 0980 ESL 1339-121
Belden Lumberg Automation LioN-P PROFINET IO-Link Master 0980 ESL 309-121
Belden Lumberg Automation LioN-P PROFINET IO-Link Master 0980 ESL 399-121
Belden Categories
Switch
Monitor
Control Unit
Control Panel
Media Converter
More Belden Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL