Sign In
Upload
Manuals
Brands
Ampac Manuals
Control Panel
EV3000 4210-0030
Ampac EV3000 4210-0030 Manuals
Manuals and User Guides for Ampac EV3000 4210-0030. We have
4
Ampac EV3000 4210-0030 manuals available for free PDF download: Installation & Commissioning, Commissioning Log Book, Installation Manual
Ampac EV3000 4210-0030 Installation & Commissioning (54 pages)
Occupant Warning & Intercommunications System 2 Wire/S004
Brand:
Ampac
| Category:
Control Panel
| Size: 2 MB
Table of Contents
Table of Contents
2
1 Non Disclosure Agreement
5
2 Certification Information
6
3 Equipment Manufacturing Details
6
4 Purpose
7
Scope
7
References
7
EV3000 System Manuals
7
Australian Standards
7
System Overview
7
5 System Description
8
Occupant Warning System
8
Occupant Intercommunication System
8
6 ECP & Main Equipment Layout
9
7 OWIS Components
10
The Emergency Control Panel
10
Ancillary Components ECP
10
Microphone
10
Master OIS Handset and All Call Switch
10
Emergency Alarm Initiating Device (EAID)
10
8 OWS, OIS and ECP Operation
11
Emergency Control Panel
11
Operating Instructions
11
Automatic / Manual / Isolate Key Switch
12
All Call Facility
12
Buzzer
13
Buzzer Mute / Alarm Acknowledge
13
Master Reset
14
Lamp Test Facility
14
System Test Facility
14
System Status Indicators
14
Zone Status (Fault Diagnostics)
15
OWS Zone Control Panel
15
OWS Zone Control Switches and Indicators
15
OWS Zone Fault
15
Alarm Origin
15
Zone Labelling
15
OIS Control Panel
16
WIP Select Switch
16
WIP Select Indicator (Red)
16
WIP Call Buzzer
16
Zone Cleared Switch
16
WIP Fault Indicator (Amber)
16
OIS System Operation
16
WIP Calling ECP
16
Conference Call
16
Completing the Call by the WIP
17
Completing the Call by the ECP
17
ECP Calling WIP
17
ECP to All WIPS (ALL CALL)
17
Completing the All Call
17
OIS Controlling ECP
17
Zone Labelling - Refer to
17
8.4.9 Zone Labelling - Refer to Appendix A
18
Remote Paging Console
18
Main Equipment Description
19
Common Board Frame
19
Signal/Speech Generator
20
Signal Generator Settings
20
Standby / Speech Generator
20
Microphone / BGM Mixer Board
21
Standby Microphone / BGM Mixer Board
21
FACP Input CPU Board
21
Main CPU
21
Amplifier Rack Frame
21
Watt Amplifier
22
120 Watt Amplifier
23
Warden Intercom Control Frame
24
OIS Control CPU
24
OIS Selector Board
24
Fan Module
24
Power Supply
25
Fault Relay
25
9 Installation
26
Unpacking and Inspection
26
Anti-Static Precautions
26
Working on the System
26
Cabinet Installation
26
Surface Mount
26
Recess Mount
26
10 Connecting the EV3000
27
FACP Input Connections (Individual Inputs)
27
Connections
27
Fusing
27
Address Setting
27
Common FACP Input Connections
28
SECP MIC, BGM and SECP OIS Handset Input Connections
28
Connections
28
100V Line Speaker Connections
29
Connections
29
Fusing
29
Visual Indicators Output Connections
31
Connections
31
Fusing
31
WIP/EAID Extension Connections
33
Connections
33
MECP to SECP Data Connections
34
Connections
34
CN5 + CN6 Power Supply to Board
34
Fusing
34
Mains Connection
35
11 Devices
36
Speakers
36
Visual Warning Devices
37
Warden Intercommunication Point (WIP)
38
Eaid
39
12 SECP and Remote Console Connections
40
13 Placing System into Operation
41
System Power up Sequence
41
Time out Setting for Automatic Evacuation Sequence
42
14 Faults
43
Fault Indicators
43
Fault Diagnostics
43
15 Trouble Shooting
44
16 Appendix A: Zone Labelling
46
17 Appendix B: Compatible Devices
47
18 Appendix C: Amplifier Addressing
48
19 Appendix D: Amplifier Strapping
49
20 Appendix E: Typical EV3000 16 & 29 Unit Wiring
50
21 Glossary of Terms
52
22 Definitions
53
Advertisement
Ampac EV3000 4210-0030 Commissioning Log Book (26 pages)
Occupant Warning & Intercommunications System
Brand:
Ampac
| Category:
Security System
| Size: 0 MB
Table of Contents
Table of Contents
2
1 Damage Report Form
3
2 Purpose
4
Scope
4
References
4
EV3000 System Manuals
4
Australian Standards
4
System Overview
4
3 Wiring
5
Mains Connection
5
Speaker Connection
5
Warden Intercom Point Connection
5
Warden Intercom Point with EAID Connected
5
Visual Alarm Connected
5
Fire Alarm Inputs
5
4 Commissioning Record
7
5 Completing the Commissioning Report
8
6 Battery Requirements
10
Calculating System Quiescent Current
10
Calculating System Full Load Current
10
Battery Size Calculation
10
Battery Discharge Current
10
Battery Information
10
7 Documentation
11
8 Appendix A Pre-Commissioning Checklist
12
9 Appendix B EV3000 Commissioning Report
13
10 Appendix C Sample Commissioning Report
14
11 Appendix D Commissioning Acceptance Report
15
12 Appendix E Maintenance Logs
17
E1 Monthly Test Log Book
17
E2 Completing the Half Yearly Log
19
E3 Battery Capacity Test
20
E4 Monthly Test Report Forms
21
E5 Half Yearly Report Form
22
13 Illustrations
23
14 Glossary of Terms
24
15 Definitions
25
Ampac EV3000 4210-0030 Installation Manual (2 pages)
Battery Detector
Brand:
Ampac
| Category:
Security Sensors
| Size: 1 MB
Table of Contents
Description
1
Installation
1
Final Operation
1
EV3000 6 Amp Power Supply Fault Connection
1
EV3000 16 Amp Power Supply Fault Connection
1
Advertisement
Ampac EV3000 4210-0030 Installation Manual (2 pages)
Visual Output Board, XENON/LED
Brand:
Ampac
| Category:
I/O Systems
| Size: 0 MB
Advertisement
Related Products
Ampac Fire Finder EN54-2
Ampac Fire Finder EN54-4
Ampac EvacU
Ampac LoopSense EN54
Ampac EvacU Elite
AMPAC FireFinder Series II AS442
Ampac FireFinder Series II AS4428
Ampac LoopSense
Ampac LoopSense EN54.2
Ampac LoopSense EN54.4
Ampac Categories
Fire Alarms
Control Panel
Security Sensors
Security System
Firefighting Equipment
More Ampac Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL