Mechanical Disassemblies - Sanyo PLC-XW10 Service Manual

Hide thumbs Also See for PLC-XW10:
Table of Contents

Advertisement

Mechanical Disassemblies

Mechanical disassemble should be made following procedures in numerical order.
Following steps show the basic procedures, therefore unnecessary step may be ignored.
Caution:
The parts and screws should be placed exactly the same position as the original otherwise it may cause loss of
performance and product safety.
1. CABINET TOP REMOVAL
Remove 5 screws and pull cabinet top upward.
2. CABINET FRONT AND SPEAKER REMOVAL
1) Remove 4 screws (2 top and 2 bottom)
forward.
B
2) Remove 2 screws
and then remove RC
board and temp board.
C
3) Remove 4 screws
and the speaker.
A
and take the cabinet front off
RC Board
Temp Board
B
A
B
-8-
A
A
C
A
Fig.1
Fig.2