Optical Parts Disassemblies
5. POLARIZED GLASS-IN ASS'Y DISASSEMBLY
1) Remove the cabinet top, front, main and component boards following to
"Mechanical Disassemblies".
2) Remove each screw and take the each polarized glass-in ass'y off
upward.
3) Release 2 hooks and remove the polarized glass-in.
6. POLARIZED GLASS-OUT ASS'Y DISASSEMBLY
1) Remove the cabinet top, front and main boards following to "Mechanical
Disassemblies".
2) Remove 4 screws by using the 2.0 mm hex driver and take the LCD
Panel/Prism ass'y off upward from the optical unit.
3) Remove each screw and take the each polarized glass-out off upward.
Note:
Do not replace the LCD
panel separately otherwise
it can not obtain proper pic-
ture.
LCD Panel/Prism Ass'y
* Mount the polarized glass as the surface
attached the phase sheet comes to the
prism side.
Fig.5-
1
LCD Panel/Prism
Ass'y
* Mount the polarized glass as the
surface attached the phase sheet
comes to the LCD panel side.
Fig.6-
1
-16-
Phase Sheet
Polarized Glass-In
Hook
Fig.5-
2
Polarized Glass-Out
LCD Panel
Fig.6-
2